• 제목/요약/키워드: Three-phase four-wire distribution systems

검색결과 13건 처리시간 0.02초

Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • Win, Tint Soe;Tanaka, Toshihiko;Hiraki, Eiji;Okamoto, Masayuki;Lee, Seong Ryong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.176-183
    • /
    • 2014
  • Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저가형 능동전력필터 (A New Low-Cost Active Power Filter to Suppress Neutral Current Harmonics in Three-Phase Four-Wire System)

  • 장민수;최세완;김기영
    • 전력전자학회논문지
    • /
    • 제7권4호
    • /
    • pp.359-365
    • /
    • 2002
  • 최근 상업용 빌딩, 주거용 빌딩 및 공장등의 저전압 3상 4선식 배전계통에서 PC, UPS, 정류기기, 조명장치 및 사무용기기등 비선형 부하의 사용이 증가하고 있으며, 이로 인한 과도한 중성선 전류는 중성선의 고장, 변압기의 과열 및 중성선과 접지사이의 전압강하등 심각한 문제를 야기시키고 있다. 본 논문에서는 3상 4선식 배전계통에서 중성선 전류 제거를 위한 새로운 저감된 용량의 능동전력필터를 제안한다. 제안한 방식은 제어가 간단하고 불평형에 기인하는 기본파 전류만이 인버터 스위치로 흐를 수 있기 때문에 인버터의 VA 정격이 작아진다. 제안한 시스템은 실험에 의하여 그 타당성을 입증한다.

공통중성선 3상4선식 배전선로의 중성선 전위상승에 관한 연구 (Researches on the Potential Rises on the Neutral Line in Three Phase, Four-Wire Distribution Line Systems)

  • 박영문
    • 전기의세계
    • /
    • 제18권6호
    • /
    • pp.23-32
    • /
    • 1969
  • The thesis has derived the formulas and computational algorithms useful for predicting and constraining the potential rises on the neutral line in 3-phase, 4-wire distribution line systems in the case of contact faults and single-line grounding faults. In addition it has suggested economically optimal designing conditions herewith of the distribution line systems in conduction with the potential restraining cost functions.

  • PDF

3상 4선식 배전계통에서 단상 능동필터를 이용한 중성선 전류의 보상 (Neutral Current Compensation Using Single Phase Active Power Filter in Three-Phase Four-Wire Electric Distribution Systems)

  • 최시영;김병섭;송종환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1046-1048
    • /
    • 2002
  • The increase of triplen harmonics in three-phase four-wire systems leads to overloaded neutral conductor, common-mode noise problems, derating of transformers, and so on. Various compensator has been designed to prevent the problems associated with the triplen harmonics. But these can not protect distribution system effectively because the triplen harmonic source is distributed extensively and distribution system type is diverse. This paper explain the operation and installation of single phase active power filter to eliminate triplen harmonics and then it is verified by simulation.

  • PDF

부하 불평형율에 대한 새로운 해석 (A New Analysis for Load Unbalance Factor)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제55권2호
    • /
    • pp.67-72
    • /
    • 2006
  • Most of the load distributions in low voltage power feeder distribution systems are designed with approximately balanced and connected at the three phase four wire systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating load unbalance. Load unbalance factor is mainly affected by the impedance of load system. Unbalanced current will draw a highly unbalanced voltage. This paper presents a new calculation method for unbalance factor under the load variation at the three phase four wire system. Load unbalance factor is measured by the power quality measurement apparatus and compared with the current unbalance factor. Two methods are indicated similar results.

High-Performance Control of Three-Phase Four-Wire DVR Systems using Feedback Linearization

  • Jeong, Seon-Yeong;Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.351-361
    • /
    • 2016
  • Power quality is a critical issue in distribution systems, where a dynamic voltage restorer (DVR) is commonly used to mitigate the voltage disturbances for loads. This paper deals with a nonlinear control for the three-phase four-wire (3P-4W) DVR under a grid voltage unbalance and nonlinear loads in the distribution system, where a novel control scheme based on the feedback linearization technique is proposed. Through feedback linearization, a nonlinear model of a DVR with a PWM voltage-source inverter (VSI) and LC filters is linearized. Then, the controller design of the linearized model is performed by applying the linear control theory, where the load voltages are kept constant by controlling the d-q-0 axis components of the DVR output voltages. To keep the load voltage unchanged, an in-phase compensation strategy is employed, where the load voltages are recovered to be the same as the previous voltage without a change in the magnitude. With this strategy, the performance of the DVR becomes faster and more stable even under unbalanced source voltages and nonlinear loads. The validity of the proposed control strategy has been verified by simulation and experimental results.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

불평형 전압 운전시의 역률보상용 커패시터 특성 연구 (A Study on the Characteristics for Power Capacitor under the Voltage Unbalance Operation)

  • 김일중;김종겸
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.36-40
    • /
    • 2008
  • Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor.

교육용 건물의 중성선 고조파 전류 측정 및 모델링 (Measurements and Modeling of Neutral Harmonic Currents on the Education Office Building)

  • 김경철;강윤모;이일무
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.111-116
    • /
    • 2002
  • With the proliferation of nonlinear loads such as personal computers in an educational office building, high neutral harmonic currents have been observed. High neutral currents in three-phase four-wire distribution power systems can cause overloaded neutral conductors, overloaded transformers, voltage distortion, common mode noise, and malfuntion of protective equipment. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuits was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB.

  • PDF

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF