• 제목/요약/키워드: Three-dimensional CT image

검색결과 195건 처리시간 0.024초

Application of 3D Simulation Surgery to Orbital Wall Fracture : A preliminary Case Study

  • Choi, Jong-Woo
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권1호
    • /
    • pp.16-18
    • /
    • 2014
  • The orbit has a very special anatomical structure. The complex anatomical structure should be restored when we encounter the patient with orbital wall fracture. Unless these specific anatomy were reconstructed well, the patient should suffer from various complications such enophthalmos, diplopia or orbital deformity. In addition, because the patient has a his own specific orbital shape, individualized approach will be necessary. The aim of this trial is to try to restore the original orbit anatomy as possible based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. In order to restore the missing skipped images between the cuts of CT data because of the thinness of the orbital walls, we manipulated the DICOM data for imaging the original orbital contour using the preoperatively manufactured mirror-image of the RP model. And we fabricated Titanium-Medpor to reconstruct three-dimensional orbital structure intraoperatively. This prefabricated Titanium-Medpor was then inserted onto the defected orbital wall and fixed. Three dimensional approach based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

계층적 모델에 의한 3차원 재구성 영상의 임의단면 표시 (Arbitrary Cross Sectional Display from Three-dimensional Reconstructed Image by Hierarchical Model)

  • 유선국;김선호
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권2호
    • /
    • pp.157-164
    • /
    • 1989
  • Three-dimensional imaging and manipulation of CT data are becoming increasingly important for deterRing the complex structure and pathologies. Octree which is a hierarchical data model is used to reconstruct three- dimensional objects from CT scans. Orthogonal cross sections are displayed by traverse the octree partially. Arbitrary oblique planes are derived by intersecting the square region of plane and cubic volume of octal node. Thia method enables the display of multi-structured complex organ ann the realization by personal computer.

  • PDF

Comparison of Target Localization Error between Conventional and Spiral CT in Stereotactic Radiosurgery

  • Kim, Jong-Sik;Ju, Sang-Kyu;Park, Young-Hwan
    • 대한방사선치료학회지
    • /
    • 제12권1호
    • /
    • pp.20-25
    • /
    • 2000
  • The accuracy of the target localization was evaluated by conventional and spiral CT in stereotactic radiosurgerv. Conventional and spiral CT images were obtained with geometrical phantom, which was designed to produce exact three-dimensional coordinates of several objects within 0.1mm error range. Geometrical phantom was attached by BRW headframe, intermediate head ring, and CT localizer. Twentv-seven slices of conventional CT image were scanned at 3 mm slice thickness. Spiral CT images were scanned at 3 mm slice thickness from the pitch value 1 to 3, and twenty-seven slices of image were obtained per each the pitch value. These CT images were transferred to a treatment planning system(X-knife, Radionics) by ethernet, Three-dimensional coordinates of these images measured from the treatment planning system were compared to known values of geometrical phantom. The mean localization error of the target localization of conventional CT was 1.4mm. In case of spiral CT, the error of the target localization was within 1.6mm from the pitch value 1 to 1.3, but was more than 30mm above the pitch value 1.5. In conclusion, as the localization error of spiral CT was increased in high pitch value compared to conventional CT, the application of spiral CT will be with caution in stereotactic radiosurgery.

  • PDF

3차원 CT 영상을 이용한 두개악안면 분석을 위한 계측점의 제안 (A proposal of landmarks for craniofacial analysis using three-dimensional CT imaging)

  • 장혜숙;백형선
    • 대한치과교정학회지
    • /
    • 제32권5호
    • /
    • pp.313-325
    • /
    • 2002
  • 3차원 CT에서는 환자의 움직임에 의한 오차와 상의 확대나 왜곡을 감소시킨 실측치를 얻을 수 있으며 두개안면부의 입체적인 영상을 구성할 수 있고 원하는 조직이나 구조물의 관찰이 용이하다 디지털 영상 기술이 빠르게 발전하고 있고 치료의 범위가 더욱 넓어지면서 두개악안면 구조의 3차원적인 분석법의 개발은 시급한 과제가 되었다. 이에 본 연구에서는 Vworks 프로그램$^{TM}$ (Cybermed Inc., Seoul, Korea)과 건조두개골을 이용하여 3차원 CT 영상의 오차와 확대율을 평가하고Vmorph-proto프로그램 $^{TM}$ (Cybermed Inc., Seoul, Korea)을 이용하여 정상인과 비대칭 환자의 3차원 CT영상에서 지정이 용이하고 반복재현성이 높은 계측점을 설정하고자 하여 다음과 같은 결론을 얻었다 ; 1. 건조두개골의 실측치와 Vworks 프로그램을 이용하여 구성한 3차원 CT영상에서 의 계측치를 비교한 결과 평균오차가 0.99mm, 확대율이 1.04%로 나타났다. 2. 3차원 CT영상에서 경조직 계측점으로 Supraorbitale, Lateral orbital margin, Infraorbitale, Natron, ANS, A point, Zygomaticomaxilla, Upper incisor, Lower incisor, B point, Pogonion, Menton, PNS, Condylar inner margin, Condylar outer margin, Porion, Condylion, Gonionl, Gonion2, Gonion3, Sigmoid notch, Basion 등이 임상적으로 유용하다고 판단되었다. 3. 3차원 CT영상에서 연조직 계측점으로 Endocanthion, Exocanthion, Soft tissue Nasion, Pronasale, Alare lateralis, Upper nostril point, Lower nostril point, Subnasale, Upper lip point, Cheilion, Stomion, Lower lip center, Soft tissue B, Pogonion, Menton, Preaurale 등이 임상적으로 유용하다고 판단되었다. Vworks 프로그램으로 3차원 CT영상을 구성하고 계측하는 것이 임상적으로 유용하다고 판단되었다. 또한 위에서 제안된 연조직 및 경조직 계측점들은 3차원 CT영상에서 반복 재현성이 높고 지정이 용이하며 해부학적 특징을 나타내주는 점들로 두개악안면 구조의 3차원적인 진단과 술전, 술후의 예측과 비교에 유용하게 사용될 것으로 사료되는 바이다.

기관협착증에서 3차원적 영상 진단의 의의 (The Significance of 3-Dimensional Imaging in Tracheal Stenosis)

  • 정동학;봉정표;이운우;노정래;성기준
    • 대한기관식도과학회지
    • /
    • 제1권1호
    • /
    • pp.82-93
    • /
    • 1995
  • Three-dimensional reconstruction of computed tomographic image(3D CT) is a well-established imaging modality which has been investigated in various clinical settings. It is commonly performed in case of congenital or developmental abnormalities, and traumatic fracture of skull and face that requires reconstruction of osseous structure. However reporting the 3D CT in laryngeal or tracheal stenosis is rare and its results are obscure. The authors performed 3D CT in six cases of tracheal stenosis and found diagnostic value of 3D CT. A Comparision of diagnostic information obtained from plain X-ray, 2D CT and 3D CT has performed in total six cases of tracheal stenosis. Surgical treatment of the tracheal stenosis was following in these cases : tracheal end to end anastomosis In 1 case, laryngotracheal end to end anastomosis in 2 cases. 3D CT information was compared with operative finding. In two of six cases, satisfactory information was not obtained from 3D CT in evaluating an exact stenosis of trachea. Future, it will be helped in evaluating of tracheal stenosis by 3D CT.

  • PDF

한국인의 3차원 무릎관절 구축 및 형상 측정 (Construction and Measurement of Three-Dimensional Knee Joint Model of Koreans)

  • 박기봉;김기범;손권;서정탁;문병영
    • 대한기계학회논문집A
    • /
    • 제28권11호
    • /
    • pp.1664-1671
    • /
    • 2004
  • It is necessary to have a model that describes the feature of the knee Joint with a sufficient accuracy. Koreans, however, do not have their own knee joint model to be used in the total knee replacement arthroplasty. They have to use European or American models which do not match Koreans. Three-dimensional visualization techniques are found to be useful in a wide range of medical applications. Three-dimensional imaging studies such as CT(computed tomography) and MRI(magnetic resonance image) provide the primary source of patient-specific data. Three-dimensional knee joint models were constructed by image processing of the CT data of 10 subjects. Using the constructed model, the dimensions of Korean knee joint were measured. And this study proposed a three-dimensional model and data, which can be helpful to develop Korean knee implants and to analyze knee joint movements.

식도 이물 모델에서 이물 탐색을 위한 삼차원 재구성법의 활용 (Detection of Foreign Body in Esophageal Foreign Body Model Using Three Dimensional Reconstruction Technique)

  • 우국성;유영삼;김동원
    • 대한기관식도과학회지
    • /
    • 제18권1호
    • /
    • pp.13-18
    • /
    • 2012
  • Objective This study was conducted to gather basic information of 3D CT in detecting and gaining information of esophageal foreign body (FB) models. Materials and Methods The chest model was made using PVC bottle, rubber balloon and plaster. Fish bone, Persimmon stone were used to mimic foreign bodies of esophageal model. The foreign body models were inserted into the balloon removing air from it and the balloon was sealed. The esophageal FB model was inserted into the chest model. The remaining space in the chest model was filled with fish paste and water to simulate soft tissue around esophagus. CT of chest model was reconstructed three-dimensionally by Rapidia software to make images of foreign body models. The axial CT, MPR image and VOI image were compared with real foreign body materials as to shape, size, location and orientation. Results Esophageal FB models were easily made. CT data gave good 3D images and showed realistic foreign body materials. Conclusion The results indicate the usefulness of 3D CT technique to help in diagnosis of esophageal foreign body models.

  • PDF

컴퓨터 단층 촬영 영상에서의 폐혈관 분할 및 정제 (Pulmonary vascular Segmentation and Refinement On the CT Scans)

  • 신민준;김도연
    • 한국정보통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.591-597
    • /
    • 2012
  • 신체 주요 장기들에 대한 영상의 중요성이 커져감에 따라 향상된 의료 장비들이 등장하였으며, 획득된 영상에 대한 개선된 화질과 활용성에 기대가 높아지고 있다. 최근 향상된 영상분석 연구를 위해 MATLAB을 이용한 영상 처리의 빈도가 커져가는 것에 기인하여 MATLAB을 이용하여 폐혈관을 분할하였다. 본 논문은 3단계로 폐 영역 분할, 폐 혈관 분할과 3차원 연결성 검사로 수행된다. 분할된 폐 영역에서 문턱치 값을 사용하여 혈관을 분할하고, 2차원 정제 과정인 혈관 두께 분류를 수행한 후 3차원 정제 과정으로 3차원 연결성 검사를 적용하였다. MATLAB을 통한 영상 처리로 의료영상 처리의 다양성 측면과 신뢰성 향상에 기여하였고 흉부 CT 영상을 이용한 관련 연구의 기반이 되리라 판단된다.

Evaluation of accuracy of 3D reconstruction images using multi-detector CT and cone-beam CT

  • Kim, Mi-Ja;Huh, Kyung-Hoe;YI, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제42권1호
    • /
    • pp.25-33
    • /
    • 2012
  • Purpose : This study was performed to determine the accuracy of linear measurements on three-dimensional (3D) images using multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). Materials and Methods : MDCT and CBCT were performed using 24 dry skulls. Twenty-one measurements were taken on the dry skulls using digital caliper. Both types of CT data were imported into OnDemand software and identification of landmarks on the 3D surface rendering images and calculation of linear measurements were performed. Reproducibility of the measurements was assessed using repeated measures ANOVA and ICC, and the measurements were statistically compared using a Student t-test. Results : All assessments under the direct measurement and image-based measurements on the 3D CT surface rendering images using MDCT and CBCT showed no statistically difference under the ICC examination. The measurements showed no differences between the direct measurements of dry skull and the image-based measurements on the 3D CT surface rendering images (P>.05). Conclusion : Three-dimensional reconstructed surface rendering images using MDCT and CBCT would be appropriate for 3D measurements.

Assessment of ASPECTS from CT Scans using Deep Learning

  • Khanh, Trinh Le Ba;Baek, Byung Hyun;Kim, Seul Kee;Do, Luu-Ngoc;Yoon, Woong;Park, Ilwoo;Yang, Hyung-Jeong
    • 한국멀티미디어학회논문지
    • /
    • 제22권5호
    • /
    • pp.573-579
    • /
    • 2019
  • Alberta Stroke Program Early Computed Tomographic Scoring (ASPECTS) is a 10-point CT-scan score designed to quantify early ischemic changes in patients with acute ischemic stroke. However, an assessment of ASPECTS remains a challenge for neuroradiologists in stroke centers. The purpose of this study is to develop an automated ASPECTS scoring system that provides decision-making support by utilizing binary classification with three-dimensional convolutional neural network to analyze CT images. The proposed method consists of three main steps: slice filtering, contrast enhancement and image classification. The experiments show that the obtained results are very promising.