DOI QR코드

DOI QR Code

Construction and Measurement of Three-Dimensional Knee Joint Model of Koreans

한국인의 3차원 무릎관절 구축 및 형상 측정

  • 박기봉 (부산대학교 기계설계공학과) ;
  • 김기범 (부산대학교 기계설계공학과) ;
  • 손권 (부산대학교 기계공학부) ;
  • 서정탁 (부산대학교 의과대학정형외과) ;
  • 문병영 (부산대학교 항공우주공학과)
  • Published : 2004.11.01

Abstract

It is necessary to have a model that describes the feature of the knee Joint with a sufficient accuracy. Koreans, however, do not have their own knee joint model to be used in the total knee replacement arthroplasty. They have to use European or American models which do not match Koreans. Three-dimensional visualization techniques are found to be useful in a wide range of medical applications. Three-dimensional imaging studies such as CT(computed tomography) and MRI(magnetic resonance image) provide the primary source of patient-specific data. Three-dimensional knee joint models were constructed by image processing of the CT data of 10 subjects. Using the constructed model, the dimensions of Korean knee joint were measured. And this study proposed a three-dimensional model and data, which can be helpful to develop Korean knee implants and to analyze knee joint movements.

Keywords

References

  1. Moon, B. Y., Son, K., Park, J. H. and Suh, J. T., 2003, 'A Method to Describe and Analyze Human Knee Joint Motion,' Journal of the Korean Society of Precision Engineering, Vol. 20, No. 10, pp. 233-239
  2. Wismans, J., Veldpaus, F. and Janssen, J., 1980, 'A Three-Dimensional Mathematical Model of the Knee Joint,' J. Biomechanics, pp. 677-685 https://doi.org/10.1016/0021-9290(80)90354-1
  3. Kurosawa, H., Walker, P. S., Abe, S., Garg, A. and Hunter, T., 1985, 'Geometry and Motion of the Knee for Implant and Orthotic Design,' J. Biomechanics, pp. 487-499 https://doi.org/10.1016/0021-9290(85)90663-3
  4. Essinger, J. R., Leyvraz, P. F., Heegard, J. H. and Robertson, D. D., 1989, 'A Mathematical Model for Evaluation of the Behaviour during Flexion of Condylar-type Knee Prostheses,' J. Biomechanics, pp. 1229-1229 https://doi.org/10.1016/0021-9290(89)90225-X
  5. Mitsumasa, M., Takuzo, I., Shozo, K., Shintaro, H., Masahiro, K., Shinichi, T. and Nobuhiro, T., 1999, 'Simulation of 3-D Motion of the Knee Joint in Total Knee Arthroplasty,' Proceedings of the Asia-Pacific Vibration Conference '99, Vol. 2, pp. 718-723
  6. Siu, D., Rudan, J., Wever, H. W., Griffiths, P., 1996, 'Femoral Articular Shape and Geometry,' J. of Arthroplasty, Vol. 11, No.2, pp. 166-173 https://doi.org/10.1016/S0883-5403(05)80012-9
  7. Chung, H. K., Choi, C. H., Choi, Y. J., Yang, M. S. and Kim, D. K., 1997, 'Analysis of Proximal Tibial Resection Surface Dimention with Korean Total Knee Arthroplasty Specimens,' Journal of Korean Knee Society, Vol. 9, No. 1, pp. 50-53
  8. Choi, K. W., 1997, Syudies for the Improvement of Bone Function, Final report of KIST
  9. Rohen, J. W., Yokochi, C. and Drecoll, E. L., 2002, Color Atlas of Anatomy, Hyun Moon, Seoul, pp. 425-434
  10. Kim, H. C., Han, S. K. and Sin, D. H., 2001, 'Direct Measurement of Patellar Thickness in Total Knee Replacement Arthroplasty,' The 19th Conference of Korean Knee Society, pp. 4-9
  11. Jung, H. K, Choi, C. H., Kim, K. T. and Kim, Y. J., 2001, 'Patellar Thickness in TKRA of Koreans,' The 19th Conference of Korean Knee Society, pp, 1-4
  12. Bae, D. K, Lee, Y. H. and Chung, S. W., 2001, 'The Study of Anatomical Measurement of Distal Femur and Fitness of Femoral Prosthesis in Total Knee Arthroplasty,' The 19th Conference of Korean Knee Society, Vol. 1, pp. 7-11

Cited by

  1. Rapid Prototyping and Reverse Engineering Application for Orthopedic Surgery Planning vol.20, pp.1, 2006, https://doi.org/10.1007/BF02916196