• 제목/요약/키워드: Three-dimensional (3D) visualization

검색결과 180건 처리시간 0.027초

미세제트 유동의 Stereoscopic micro-PIV측정 (Stereoscopic micro-PIV measurements of jet flow)

  • 유청환;김형범
    • 한국가시화정보학회지
    • /
    • 제5권1호
    • /
    • pp.43-48
    • /
    • 2007
  • Micro-PIV(particle image velocimetry) has been widely used to measure the velocity of micro flow. Although this micro-PIV method can give accurate 2D instantaneous velocity information of mea-surement plane, it cannot resolve the out of plane component of velocity vectors. Lots of the micro fluidic devices generate three-dimensional flow and 3D measurement of velocity is useful to understand the physics of micro flow phenomena. In this study, we constructed stereoscopic micro-PIV(SMPIV) system and applied this method to the impinging micro jet flow. The results show that this method can produce accu-rate 3D reconstruction of micro jet flow.

스테레오 PTV와 스테레오 PIV에 의한 선박프로펠러 후류측정 (Measurements of a Ship's Propeller Wake with Stereoscopic-PIV and Stereoscopic-PTV)

  • 도덕희;황태규;이상준
    • 한국가시화정보학회지
    • /
    • 제5권2호
    • /
    • pp.26-32
    • /
    • 2007
  • Stereoscopic PTV and Stereoscopic-PIV measurements have been carried out for the studies of the wake of a ship's propeller. Stereoscopic photogrammetry based on a 3D-PTV principle was introduced using two high-definition cameras(1k x 1k, 30Hz). The arrangement of the two cameras was based on angular position. The pair-matching of the three-dimensional velocity vectors were based on Genetic Algorithm based 3D-PTV technique. The results obtained by both measurement systems have been compared at the advance ratio J=0.88(290 rpm, d=54 mm). Turbulent properties have also been compared each other at the same condition.

단일카메라 3차원 입자영상추적유속계-액적내부 유동측정 (Single Camera 3D-Particle Tracking Velocimetry-Measurements of the Inner Flows of a Water Droplet)

  • 도덕희;성형진;김동혁;조경래;편용범;조용범
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.1-6
    • /
    • 2006
  • Single-Camera Stereoscopic Vision three-dimensional measurement system has been developed based upon 30-PTV algorithm. The system consists of one camera $(1k\times1k)$ and a host computer. To attain three-dimensional measurements a plate having stereo holes has been installed inside of the lens system. Three-dimensional measurements was successfully attained by adopting the conventional 30-PTV camera calibration methods. As applications of the constructed measurement system, a water droplet mixed with alcohol was constructed on a transparent plastic plate with the contacted fluid diameter 4mm, and the particles motions inside of the droplet have been investigated with the constructed measurement system. The measurement uncertainty of the constructed system was 0.04mm, 0.04mm and 0.09mm for X, Y and Z coordinates.

  • PDF

CAD 도면을 이용한 건축물 내부 공간의 3차원 GIS 네트워크 모델링 (3D GIS Network Modeling of Indoor Building Space Using CAD Plans)

  • 강정아;염재홍;이동천
    • 한국측량학회지
    • /
    • 제23권4호
    • /
    • pp.375-384
    • /
    • 2005
  • 도시계획, 이동통신계획, 교통계획, 환경조사, 재해${\cdot}$재난 관리 등의 다양한 분야에서 효율적인 시설물 관리를 위한 3차원 도시모델의 사용이 증가하고 있다. 특히 최근의 건물모델링은 CAD와 GIS의 기술로 통합되는 추세이다. 현재까지 연구되어 온 건물모델링은 주로 외부 시각화를 위한 것이었으나 보다 다양한 분야에서 활용하기 위해 건물 내부에 대한 모델링의 필요성과 중요성이 증가하고 있다. 3차원 건물모델링은 컴퓨터 그래픽스, CAD, GIS 분야에서 서로 다른 개념으로 발전되어 왔다. CAD와 컴퓨터 그래픽스 기반의 모델은 정밀한 시각화 표현 기능이 발전하였으나 객체에 대한 속성정보가 부족하며, GIS 기반의 모델은 속성정보와 위상기하학을 이용하는 공간 분석 및 연산 기능이 강력하므로 GIS와 CAD 통합된 모델링이 필요하다. 본 연구에서는 3차원 건물모델의 내부구조를 복원하기 위해서 건축물 관리대장에 포함되어 있는 CAD 설계도면을 이용하는 방법을 제시하고 있다. 기하학적 요소로 구성된 CAD 도면에 위상기하학적인 정보를 생성하고 내부 공간을 분할하여 3차원으로 복원한 뒤, 추가적인 속성정보를 건물 데이터베이스에 입력하였다. 오늘날 규모가 커지고 복잡해지는 건물 내부의 효과적이고 체계적인 3차원 공간분석 및 서비스 제공을 위한 GIS 네트워크 모델을 생성하였다.

삼차원 STEP 데이터 뷰어 개발 (An Implementation of Three-Dimensional STEP Data Viewer)

  • 최영;여창훈
    • 한국정밀공학회지
    • /
    • 제16권9호
    • /
    • pp.54-61
    • /
    • 1999
  • Three dimensional CAD data viewer helps a user to view and use many different types of CAD data without having costly programs that produced them loaded on their computers. A viewer for standard data formats such as STEP and IGES is more useful since most of the CAD systems provide translators for them. We developed a 3D CAD viewer for STEP AP203 solid and assembly data. In addition to the standard shading and assembly tree display, functions for 3D markups and measurement of distance and angles were implemented.

  • PDF

Three-Dimensional Digital Subtraction Angiographic Evaluation of Aneurysm Remnants after Clip Placement

  • Ahn, Soon-Seob;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권3호
    • /
    • pp.185-190
    • /
    • 2010
  • Objective : The aneurysm remnants rate was evaluated via three-dimensional digital subtraction angiography (3D-DSA) in the postoperative evaluation of clipped aneurysms. Methods : Data on surgically clipped aneurysms of anterior circulation obtained via postoperative 3D-DSA from February 2007 to March 2009 were gathered. The results of the postoperative 3D-DSA and of two-dimensional digital subtraction angiography (2D-DSA) for the detection of aneurysm remnants were compared, and an investigation was performed as to why 2D-DSA had missed some aneurysm remnants that were detected in the 3D-DSA. Various surgical factors that revealed aneurysm remnants in the 3D-DSA were also evaluated. Results : A total of 39 neck remnants of 202 clipped aneurysms (19.3%) were confirmed in 3D-DSA, and these were classified according to Sindou's classification of aneurysm remnants. Patients with only a neck remnant found in the 3D-DSA represented 17.3% (35/202 aneurysms) of the whole series, and those with a residuum of neck plus sac found in the 3D-DSA represented 1.9% (4/202 aneurysms). The causes of aneurysm remnants were no full visualization (14/39, 35.9%), parent and perforator artery protection (10/39, 25.6%), clip design problems (8/39, 20.5%), and broadnecked aneurysm (7/39, 17.9%). Conclusion : Patients with ${\leq}2$mm aneurysm remnants showed an increased risk of undetectable aneurysm remnants in the 2D-DSA. The most frequent location of the missed aneurysm in 2D-DSA was the anterior communicating artery. 3D-DSA showed more aneurysm remnants than what is indicated in the existing literature, the 2D-DSA.

Measurement of Turbulent Intensity Distributions of a Cylinder Wake

  • Doh, Deog Hee;Cho, Gyeong Rae;Moon, Kyeong Rok;Cho, Yong Beom
    • 한국가시화정보학회지
    • /
    • 제11권1호
    • /
    • pp.41-47
    • /
    • 2013
  • Turbulence properties of a cylinder wake (d=10 mm) have been investigated with a new volume PTV algorithm. The measurement system consists of two-high-cameras(1 $k{\times}1$ k), a Nd-Yag laser and a host computer. A fitness function representing three-dimensional coherency has been adopted to sort out spurious vectors. A hybrid fitness function representing the relations between the fitness and the three-dimensional shortest distances constructed by the two collinears of the two cameras has been also adopted. The constructed algorithm has been employed for the measurements of the cylinder wakes. The Reynolds numbers tested in this paper are 360, 540, 720, 900, 1080 and 1260. More than 10,000 instantaneous 3D vectors have been obtained by the constructed system. The volumetric distributions of the turbulence intensities (for u', v', w') indicate that clearly different patterns for all Reynolds numbers and imply that a regular pattern (like a similarity rule) for the turbulent properties exists.

3차원 흉부 CT에서 추체 골 전이 병변에 대한 반자동 검출 기법 및 분류 시스템 개발 (Development of a Semi-Automated Detection Method and a Classification System for Bone Metastatic Lesions in Vertebral Body on 3D Chest CT)

  • 김영재;이승현;최자영;선혜영;김광기
    • 한국통신학회논문지
    • /
    • 제38C권10호
    • /
    • pp.887-895
    • /
    • 2013
  • 골 전이 암은 여러 장기에 생긴 암이 질병이 경과함에 따라 뼈로 옮아가는 것으로서, 암 환자에게서 주로 발생하는 합병증 중 하나이다. 골 전이는 골 용해성 전이와 골 형성성 전이로 구분되며, CT에서 골 전이의 진단은 임상적으로 매우 유용할 수 있으나, 많은 판독건수로 인하여 중요한 병변이 간과되는 경우가 많고, 이를 통해 골 전이 암을 조기에 진단하지 못하는 경우가 발생할 수 있다. 이에 본 논문에서는 흉부 CT의 단층 영상들을 3차원 볼륨 데이터로 구성하여 3차원 영상처리 알고리즘을 적용하여 골 전이 병변을 검출하고 3차원 가시화를 수행하였으며, 총 10개 데이터에 대해 민감도를 측정한 결과, 골 형성성 병변이 평균 94.1%, 골 용해성 병변이 평균 90.0%의 값을 나타내어 골 전이 진단에서의 활용에 대한 높은 가능성과 잠재적인 유용성을 확인할 수 있었다.

스테레오 카메라를 이용한 3차원 정보의 가시화 (Visualization of The Three Dimensional Information Using Stereo Camera)

  • 이남호;박순용;이승민
    • 전자공학회논문지SC
    • /
    • 제47권4호
    • /
    • pp.15-20
    • /
    • 2010
  • 스테레오 카메라에 의해 취득된 대상물체의 좌, 우 영상을 이용하여 3차원 형상 정보를 추출하여 가시화 하는 기법 및 주시 각 제어 알고리즘을 적용하여 입체감 있는 영상으로 출력하는 기술에 관한 연구이다. 효율적인 3차원 형상 정보 추출을 위해, 카메라 렌즈의 왜곡 보정 및 에너지 함수를 적용한 정합을 실시하였다. 특히, 다 방향 시차영상에 정합선 최적화 기법을 적용하여 정합 방향에 따른 다방향성 방법과 신뢰확장 방법의 약점을 보완하였다. 정합된 관심영역에 대한 3차원 형상정보를 VRML(virtual reality modeling language)을 사용하여 나타내었고, 주시각 제어를 통하여 입체감 있는 영상을 출력하였다. 이는 관측자에게 보다 향상된 3차원 정보를 제공할 수 있을 것이다.

3D Visualization Technique for Occluded Objects in Integral Imaging Using Modified Smart Pixel Mapping

  • Lee, Min-Chul;Han, Jaeseung;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • 제15권4호
    • /
    • pp.256-261
    • /
    • 2017
  • In this paper, we propose a modified smart pixel mapping (SPM) to visualize occluded three-dimensional (3D) objects in real image fields. In integral imaging, orthoscopic real 3D images cannot be displayed because of lenslets and the converging light field from elemental images. Thus, pseudoscopic-to-orthoscopic conversion which rotates each elemental image by 180 degree, has been proposed so that the orthoscopic virtual 3D image can be displayed. However, the orthoscopic real 3D image cannot be displayed. Hence, a conventional SPM that recaptures elemental images for the orthoscopic real 3D image using virtual pinhole array has been reported. However, it has a critical limitation in that the number of pixels for each elemental image is equal to the number of elemental images. Therefore, in this paper, we propose a modified SPM that can solve this critical limitation in a conventional SPM and can also visualize the occluded objects efficiently.