• 제목/요약/키워드: Three parallel operation

검색결과 140건 처리시간 0.027초

System Construction Method of Parallel Operation System constructed with Three Electric Power Converters

  • Ishikura, Keisuke;Inaba, Hiromi;Kishine, Keiji;Nakai, Mitsuki;Ito, Takuma
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.451-457
    • /
    • 2014
  • Parallel operation systems have an advantage in that they can be constructed quickly and inexpensively by combining existing electric power converters. However, in this case, there is a peculiar problem in that a cross current flows between the electric power converters. To design a control system more simply and commonalize the core of combination reactors, we reviewed a system construction method for parallel operation systems constructed with three electric power converters.

병렬 연결된 다수 대 계통연계형 인버터를 위한 단독운전 방지 기법 (The Anti-islanding Scheme for a Number of Grid-connected Inverters Under Parallel Operation)

  • 김동균;조상윤;이영권;최익;최주엽
    • 한국태양에너지학회 논문집
    • /
    • 제37권3호
    • /
    • pp.13-22
    • /
    • 2017
  • Anti-islanding scheme of grid-connected inverter is a key function of standards compliance, since unintentional islanding results in safety hazards, reliability, and many other issues. Therefore, many anti-islanding schemes have been researched, however, most of them have problems, which deteriorate performance of islanding detection under parallel-operation. Therefore, this paper proves the reason of problems and proposes a new anti-islanding scheme that has precise islanding detection under parallel-operation in single-phase and three-phase system. Finally, both simulation and experimental result validate the proposed scheme.

Time Complexity Measurement on CUDA-based GPU Parallel Architecture of Morphology Operation

  • Izmantoko, Yonny S.;Choi, Heung-Kook
    • 한국멀티미디어학회논문지
    • /
    • 제16권4호
    • /
    • pp.444-452
    • /
    • 2013
  • Operation time of a function or procedure is a thing that always needs to be optimized. Parallelizing the operation is the general method to reduce the operation time of the function. One of the most powerful parallelizing methods is using GPU. In image processing field, one of the most commonly used operations is morphology operation. Three types of morphology operations kernel, na$\ddot{i}$ve, global and shared, are presented in this paper. All kernels are made using CUDA and work parallel on GPU. Four morphology operations (erosion, dilation, opening, and closing) using square structuring element are tested on MRI images with different size to measure the speedup of the GPU implementation over CPU implementation. The results show that the speedup of dilation is similar for all kernels. However, on erosion, opening, and closing, shared kernel works faster than other kernels.

대전력 3상 유도전동기의 고정자권선을 이용한 전압원 인버터의 병렬운전 (Parallel Operation of Voltage Source Inverters by Using Stator Windings of High Power Three-Phase Induction Motors)

  • 김인동;노의철;전성즙
    • 한국정보통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.815-820
    • /
    • 2004
  • 본 논문에서는 고압 대전력 3상 유도전동기의 고정자 권선을 이용한 전압원 인버터의 병렬운전 방식을 제안한다. 현재 사용되고 있는 대부분의 4극 이상 대전력 유도전동기는 각 상의 권선이 외부에서 접근이 가능하도록 외부단자가 설치되어 있으며, 이들 외부 단자를 이용하여 복수대의 전압원 인버터를 병렬운전 하여 대전력 유도전동기를 구동할 수 있다. 이와 같이 고압 대전력 유도전동기를 복수 개의 전압원 인버터를 병렬 운전하여 구동할 경우, 특정 인버터의 고장발생 시 비록 구동 토오크는 감소될지라도, 나머지 인버터로 시스템을 계속 구동할 수 있어 시스템의 고장대처능력을 향상시킬 수 있다. 또한 병렬 운전되고 있는 각 인버터의 스위칭 동작에 대해 서로 위상차를 갖게 함으로서, 등가 스위칭 주파수를 증가시켜 출력 토오크 리플 감소와 입력 전류 리플 감소, DC Link 커패시터의 크기 감소와 같은 좋은 특성을 얻을 수 있다. 또한 각 인버터로의 전력의 분산에 의해 시스템에서 발생하는 EMI영향을 감소시킬 수 있다. 본 논문에서는 제안한 방식을 컴퓨터 시뮬레이션을 통해 특성을 증명하였다.

PMSG를 이용한 풍력 발전 시스템의 3병렬 운전과 계통 연계 기술 (Three-Parallel System Operation and Grid-Connection Technique for High-Power Wind Turbines using a PMSG)

  • 이상혁;정해광;이교범;최세완;최우진
    • 전력전자학회논문지
    • /
    • 제15권4호
    • /
    • pp.296-308
    • /
    • 2010
  • 본 논문은 영구자석형 동기발전기를 이용한 풍력발전 시스템의 3병렬 운전과 계통연계 기술을 제안한다. 영구자석형 풍력발전 시스템에서 back-to-back 컨버터는 발전기와 계통에 직접 연결되므로 시스템 정격에 준하는 전력 반도체 소자와 필터가 요구된다. 본 논문은 시스템의 전력변환부를 3병렬로 연결하고 병렬 운전에 의해 발생할 수 있는 순환 전류는 적절한 내부 인덕터 선정으로 해결한다. 낮은 스위칭 주파수로 운전되는 대용량 풍력발전 시스템의 THD 규정을 만족시키기 위해 최적 설계된 LCL필터를 사용하고 LCL필터에 의해 발생할 수 있는 공진 문제는 전력이론을 통한 능동 댐핑 기법을 통하여 추가적인 손실 없이 보상한다. 또한 계통 왜곡 및 불평형 시 발생할 수 있는 전력 품질의 문제는 추가적인 보상 알고리즘을 적용하여 향상시킨다. 시뮬레이션 및 실험을 통하여 병렬 운전 시스템과 알고리즘의 타당성을 검증한다.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

철도차량용 PWM 컨버터방식 비교 (The Comparison of PWM Converter's Topology in Electric Train)

  • 이현원;김남해
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.97-100
    • /
    • 1999
  • AC to DC single phase PWM converter for traction application requires rated high power and voltage. Therefor, series or parallel operation converters are necessary with considering the limitation of the power device specification. This paper compares the characteristic between two parallel operation of conventional PWM converter and Single phase three level converter about comparison of power circuit, cooling system control method and harmonic current by computer simulation.

  • PDF

H.264/AVC 복호기를 위한 고성능 연산처리 인트라 예측기 설계 (A Design of High Performance Operation Intra Predictor for H.264/AVC Decoder)

  • 김선철;류광기
    • 한국정보통신학회논문지
    • /
    • 제16권11호
    • /
    • pp.2503-2510
    • /
    • 2012
  • 본 논문에서는 H.264/AVC 복호기를 위한 고성능 연산처리 인트라 예측기를 제안한다. 기존의 인트라 예측기는 $4{\times}4$블록에 적용되는 17개의 예측모드를 효율적으로 연산하기 위해 공통 연산기를 사용하였다. 하지만 기존의 공통 연산기는 한 픽셀에 적용되는 연산 수식을 분석하여 설계되었기 때문에, 16개 픽셀의 $4{\times}4$ 블록을 연산하기 위해 4개의 공통 연산기를 사용하며 4 사이클을 소요한다. 본 논문에서는 병렬 연산을 위한 T3(Three Type Transform) 연산기를 제안한다. 제안하는 T3 연산기는 17개의 인트라 예측 모드를 3가지 형태로 나누어, $4{\times}4$ 블록의 16개 픽셀에 적용되는 연산 수식을 한 사이클에 처리한다. 제안하는 인트라 예측기와 기존의 인트라 예측기의 예측 수행 사이클을 각 모드 별로 비교한 결과, 제안하는 인트라 예측기가 평균 58.95%의 향상된 결과를 얻었다.

배터리 충전을 위한 소형풍력 발전 시스템의 병렬 운전방안에 관한 연구 (A Study on the Parallel Operation Strategy of Small Wind Turbine System for Battery Charging)

  • 손영득;구현근;김장목
    • 전력전자학회논문지
    • /
    • 제19권6호
    • /
    • pp.549-556
    • /
    • 2014
  • This study proposes a parallel operation strategy for small wind turbine systems. A small wind turbine system consists of blade, permanent magnet synchronous generator, three-phase diode rectifier, DC/DC buck converter, and the battery load. This configuration has reliability, simple control algorithm, high efficiency, and low cost. In spite of these advantages, the system stops when unexpected failures occur. Possible failures can be divided into mechanical and electrical parts. The proposed strategy focuses on the failure of electrical parts, which is verified by numerical analysis through equivalent circuit and acquired general formula of small wind power generation systems. Simulation and experimental results prove its efficiency and usefulness.

승압형 DC-DC 컨버터의 설계 및 병렬운전에 관한 연구 (A Study on the Design of Step Up DC-DC Converter and Parallel Operation)

  • 서광덕;홍찬욱;설승기;박민호
    • 대한전기학회논문지
    • /
    • 제41권6호
    • /
    • pp.579-587
    • /
    • 1992
  • This paper is to study on the step-up DC-DC converter for power system which yields output characteristics of low voltage and high current, such as fuel cell generation system. DC-AC-DC scheme is suggested for high ratio of voltage conversion. Three phase MOSFET-SPWM inverter is adopted for intermediate AC conversion and inverter output frequency is chosen at 400[Hz] in order to reduce the size of magnetic circuit and DC filter. Since control strategy which combines voltage controller with current controller in parallel is used, good output performance is obtained both in steady state and in transient state like load variation, not only in single unit operation but also in parallel operation.