• Title/Summary/Keyword: Three dimensional body

Search Result 852, Processing Time 0.031 seconds

Feasibility Study of Gait Recognition Using Points in Three-Dimensional Space

  • Kim, Minsung;Kim, Mingon;Park, Sumin;Kwon, Junghoon;Park, Jaeheung
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.124-132
    • /
    • 2013
  • This study investigated the feasibility of gait recognition using points on the body in three-dimensional (3D) space based on comparisons of four different feature vectors. To obtain the point trajectories on the body in 3D, gait motion data were captured from 10 participants using a 3D motion capture system, and four shoes with different heel heights were used to study the effects of heel height on gait recognition. Finally, the recognition rates were compared using four methods and different heel heights.

Development of Three Dimensional Scanner for Anthropometric Measurement (인체측정용 3차원 스캐너 제작)

  • Kim, Min-Hyo;Nam, Yun-Ja
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.77-88
    • /
    • 2001
  • A three dimensional body scanner for anthropomentric measurement has been developed. In this study, the slit laser beam projection method followed by digital image processing was used to provide accurate spatial data with the typical optical triangulation method to overcome the many difficulties in traditional in accurate and time-consuming tactic measurement method using rulers and gauges. Compared with other commercialized scanners. this system can obtain a relatively wide range of data at a much lower cost by the specially designed scanning process such as the simultaneous acquisition of vertical and horizontal body cross-section profiles.

  • PDF

An improved Rankine source panel method for three dimensional water wave problems

  • Feng, Aichun;You, Yunxiang;Cai, Huayang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.70-81
    • /
    • 2019
  • An improved three dimensional Rankine source method is developed to solve numerically water wave problems in time domain. The free surface and body surface are both represented by continuous panels rather than a discretization by isolated points. The integral of Rankine source 1/r on free surface panel is calculated analytically instead of numerical approximation. Due to the exact algorithm of Rankine source integral applied on the free surface and body surface, a space increment free surface source distribution method is developed and much smaller amount of source panels are required to cover the fluid domain surface than other numerical approximation methods. The proposed method shows a higher accuracy and efficiency compared to other numerical methods for various water wave problems.

Coordination Pattern of Upper Limb of Sweep Shot Movement in Ice Hockey (아이스하키 스위프 샷(Sweep shot) 동작의 상지의 협응 형태)

  • Choi, Ji-Young;Lee, Eui-Lin
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.169-179
    • /
    • 2007
  • The purpose of this study was to investigate the relations between the segments of the body and to qualitatively analyze coordination pattern of joints and segments during Sweep Shot movement in Ice Hockey, by utilizing coordination variables was angle vs. angle plots. By the utilization the three dimensional anatomical angle cinematography, the angles of individual joint and segment according to sweep shot in ice hockey. The subjects of this study were five professional ice hockey players. The reflective makers were attached on anatomical boundary line of body. For the movement analysis three dimensional cinematographical method(APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 6.1 graphical programming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and ice hockey stick were defined. The three dimensional anatomical angular displacement and coordination pattern of trunk and Upper limb(shoulder-elbow, elbow-wrist linked system) showed important role of sweep shot in ice hockey. As the result of this paper, for the successful movement of sweep shot in ice hockey, it is most important role of coordination pattern of trunk-shoulder, shoulder-elbow and elbow-wrist. specially turnk movememt as a proximal segment. Coordination pattern of Upper Limb(upperarm-forearm-hand) of Sweep Shot movement in Ice Hockey that utilizes coordination variables seems to be one of useful research direction to understand basic control mechanisms of Ice hockey sweep shooting linked system skill. this study result showed flexion-extension, adduction-abduction and internal-external rotation of trunk are important role of power and shooting direction coordination pattern of upper Limb of Sweep Shot movement in Ice Hockey.

Free Surface Oscillation in Sloshing Problem Predicted with ALE Method

  • Ushijima Satoru
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.11-22
    • /
    • 1999
  • A numerical prediction method has been proposed to predict non-linear free surface oscillation in a three-dimensional container. The fluid motions are numerically predicted with Navier-Stokes equations discretized in a Lagrangian scheme with sufficient numerical accuracy. The profile of a free surface is precisely represented with three-dimensional body-fitted coordinates (BFC), which are regenerated in each computational step on the basis of the arbitrary Lagrangian-Eulerian (ALE) formulation. In order to confirm the reliability of the computational method, it was firstly applied to three-dimensional flows within complicated-shaped rigid boundaries, such as curved pipes and ducts. Than it was applied to benchmark computations related to free surface oscillations. Following these basic verifications, non-linear sloshings in a cylindrical tank and transitions from sloshing to swirling motions were numerically predicted. Throughout these computations, the applicability of the present computational method has been confirmed and some of the predicted free surface motions were visualized as sequential images and animations to understand their dynamic futures.

  • PDF

Nasoethmoid orbital fracture reconstruction using a three-dimensional printing-based craniofacial plate

  • Hyun Ki, Hong;Do Gon, Kim;Dong Hun, Choi;Anna, Seo;Ho Yun, Chung
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.6
    • /
    • pp.278-281
    • /
    • 2022
  • The face is one of the most important parts of the body. Untreated facial fractures can result in deformities that can be harmful to patients. Three-dimensional (3D) printing is a rapidly evolving technology that has recently been widely applied in the medical field as it can potentially improve patient treatment. Although 3D printing technology is mostly used for craniofacial surgery, some studies have proved that it can be used to treat nasoethmoid orbital fractures. In this study, a patient-customized plate was constructed using a 3D printer and applied in a simulated surgery for the treatment of nasoethmoid orbital fracture.

Using a Body Scanner in Assessing Perceptions of Attractiveness: Cross-Regional Study

  • Aghekyan, Marine;Kim, Dong-Eun;Lichty, Margaret
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.6
    • /
    • pp.799-808
    • /
    • 2013
  • Previous research reported that body size measured as Body Mass Index (BMI) and body shape measured as waist-hip-ratio (WHR) are two essential factors that form the perceptions of body attractiveness. However, the debate on the importance of BMI versus WHR is ongoing. In addition, scholarly articles, that focus on the role of geographic and cultural variability on perceptions of attractiveness, report inconsistent results. Some suggested that according to globalization and the rise of mass media, geographic variability of perceptions of attractiveness have been altered, while others believed that it remains. This study cross-regionally investigates the role of body size and body shape on the perceptions of female attractiveness. Samples were composed of 107 female college students in Alabama and 107 female college students in California. Participants viewed 27 three-dimensional body scan images of women in three body shapes (pear, hourglass, and rectangle) and three body sizes (underweight, normal weight, and overweight) and rated their perceptions of attractiveness. Images were shown to students in a random order with an overhead projector and Microsoft Office PowerPoint software. A three-way mixed-ANOVA was conducted to analyze the data. The results of the study showed that some regional differences exist between the two sample groups. However, regardless of the regional difference, hourglass shapes were perceived to be the most attractive shape and underweight sizes were perceived to be the most attractive size for both samples.

The Three Dimensional Analysis of the Upper Body's Segments of the Elderly during Walking (보행 시 노인의 상체 움직임에 대한 3차원적 분석)

  • Kim, Hee-Su;Yoon, Hee-Joong;Ryu, Ji-Seon;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.1-15
    • /
    • 2004
  • The purpose of this study was to investigate the kinematic variables of the upper part of the body for 8 elderly men during walking. For this study, kinematic data were collected using a six-camera (240Hz) Qualisys ProReflex system. The room coordinate system was right-handed and fixed in space, with righted orthogonal segment coordinate systems defined for the head, trunk, and pelvis. Based on a rigid body model, reflective marker triads were attached on the 3 segments. Three-dimensional Cartesian coordinates for each marker were determined at the time of recording using a nonlinear transformation(NLT) technique with ProReflex software (Qualisys, Inc.). Coordinate data were low-pass filtered using a fourth-order Butterworth with cutoff frequency of 6Hz. Three-dimensional angles of the head, trunk, and pelvis segment were determined using a Cardan method. On the basis of each segment angle, angle-angle plot used to estimated the movement coordinations between segments. The conclusions were as follows; (1) During the support phase of walking, the elderly people generally kept their, head the flexional and abductional posture. Particularly, the elderly displayed little internal/external rotation. (2) The elderly people showed extensional and external rotation postures in the trunk movement. Particularly, It showed the change from adduction into abduction at the heel contact event of the stance phase. (3) The elderly people showed almost same pelvis movement from the flexion into extension, from the abduction into adduction, and from internal rotation into external rotation at the mid stance and toe off of the stance phase.

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.