References
- Zimmermann M, Mehl A, Mormann WH, Reich S. Intraoral scanning systems - a current overview. Int J Comput Dent 2015;18:101-29.
- Yuzbasioglu E, Kurt H, Turunc R, Bilir H. Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 2014;14:10. https://doi.org/10.1186/1472-6831-14-10
- Joda T, Lenherr P, Dedem P, Kovaltschuk I, Bragger U, Zitzmann NU. Time efficiency, difficulty, and operator's preference comparing digital and conventional implant impressions: a randomized controlled trial. Clin Oral Implants Res 2016 Sep 5.
- Chochlidakis KM, Papaspyridakos P, Geminiani A, Chen CJ, Feng IJ, Ercoli C. Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis. J Prosthet Dent 2016;116:184-90. https://doi.org/10.1016/j.prosdent.2015.12.017
- Ender A, Attin T, Mehl A. In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions. J Prosthet Dent 2016;115:313-20. https://doi.org/10.1016/j.prosdent.2015.09.011
- Guth JF, Runkel C, Beuer F, Stimmelmayr M, Edelhoff D, Keul C. Accuracy of five intraoral scanners compared to indirect digitalization. Clin Oral Investig 2016 Jul 12.
- Boeddinghaus M, Breloer ES, Rehmann P, Wostmann B. Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 2015;19:2027-34. https://doi.org/10.1007/s00784-015-1430-7
- Hamalian TA, Nasr E, Chidiac JJ. Impression materials in fixed prosthodontics: influence of choice on clinical procedure. J Prosthodont 2011;20:153-60. https://doi.org/10.1111/j.1532-849X.2010.00673.x
- Wadhwani CP, Johnson GH, Lepe X, Raigrodski AJ. Accuracy of newly formulated fast-setting elastomeric impression materials. J Prosthet Dent 2005;93:530-9. https://doi.org/10.1016/j.prosdent.2005.03.007
- Eames WB, Sieweke JC, Wallace SW, Rogers LB. Elastomeric impression materials: effect of bulk on accuracy. J Prosthet Dent 1979;41:304-7. https://doi.org/10.1016/0022-3913(79)90013-1
- Mansfield MA, Wilson HJ. Elastomeric impression materials. A method of measuring dimensional stability. Br Dent J 1975;139:267-72. https://doi.org/10.1038/sj.bdj.4803587
- Schnell R, Phillips RW. Dimensional stability of rubber base impressions and certain other factors affecting accuracy. J Am Dent Assoc 1958;57:39-48. https://doi.org/10.14219/jada.archive.1958.0248
- Boulton JL, Gage JP, Vincent PF, Basford KE. A laboratory study of dimensional changes for three elastomeric impression materials using custom and stock trays. Aust Dent J 1996;41:398-404. https://doi.org/10.1111/j.1834-7819.1996.tb06026.x
- Van Noort R. Impression Materials. In: Van Noort R. Introduction to dental materials. London: Mosny Elsevier; 2007, p. 186-208.
- Shillingburg HT Jr, Hatch RA, Keenan MP, Hemphill MW. Impression materials and techniques used for cast restorations in eight states. J Am Dent Assoc 1980;100:696-9. https://doi.org/10.14219/jada.archive.1980.0228
- Clark DM, Oyen OJ, Feil P. The use of specific dental schooltaught restorative techniques by practicing clinicians. J Dent Educ 2001;65:760-5.
- Chee WW, Donovan TE. Polyvinyl siloxane impression materials: a review of properties and techniques. J Prosthet Dent 1992;68:728-32. https://doi.org/10.1016/0022-3913(92)90192-D
- Chugh A, Arora A, Singh VP. Accuracy of different puttywash impression techniques with various spacer thickness. Int J Clin Pediatr Dent 2012;5:33-8. https://doi.org/10.5005/jp-journals-10005-1131
- Nissan J, Laufer BZ, Brosh T, Assif D. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent 2000;83:161-5. https://doi.org/10.1016/S0022-3913(00)80007-4
- Shiozawa M, Takahashi H, Finger WJ, Iwasaki N. Effects of the space for wash materials on sulcus depth reproduction with addition-curing silicone using two-step putty-wash technique. Dent Mater J 2013;32:150-5. https://doi.org/10.4012/dmj.2012-228
- Manoj SS, Cherian KP, Chitre V, Aras M. A comparative evaluation of the linear dimensional accuracy of four impression techniques using polyether impression material. J Indian Prosthodont Soc 2013;13:428-38. https://doi.org/10.1007/s13191-013-0255-9
- Terry DA, Tric O, Blatz M, Burgess JO. The custom impression tray: fabrication and utilization. Dent Today 2010;29:132, 134-5.
- Singh K, Sahoo S, Prasad KD, Goel M, Singh A. Effect of different impression techniques on the dimensional accuracy of impressions using various elastomeric impression materials: an in vitro study. J Contemp Dent Pract 2012;13:98-106.
- Saunders WP, Sharkey SW, Smith GM, Taylor WG. Effect of impression tray design and impression technique upon the accuracy of stone casts produced from a putty-wash polyvinyl siloxane impression material. J Dent 1991;19:283-9. https://doi.org/10.1016/0300-5712(91)90072-7
- Nissan J, Rosner O, Bukhari MA, Ghelfan O, Pilo R. Effect of various putty-wash impression techniques on marginal fit of cast crowns. Int J Periodontics Restorative Dent 2013;33:e37-42. https://doi.org/10.11607/prd.0713
- Dugal R, Railkar B, Musani S. Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study. J Int Oral Health 2013;5:85-94.
- Kumar V, Aeran H. Evaluation of effect of tray space on the accuracy of condensation silicone, addition silicone and polyether impression materials: an in vitro study. J Indian Prosthodont Soc 2012;12:154-60. https://doi.org/10.1007/s13191-012-0124-y
- Nissan J, Gross M, Shifman A, Assif D. Effect of wash bulk on the accuracy of polyvinyl siloxane putty-wash impressions. J Oral Rehabil 2002;29:357-61. https://doi.org/10.1046/j.1365-2842.2002.00820.x
- Rathee S, Eswaran B, Eswaran M, Prabhu R, Geetha K, Krishna G, Jagadeshwari. A comparison of dimensional accuracy of addition silicone of different consistencies with two different spacer designs - In-vitro study. J Clin Diagn Res 2014;8:ZC38-41.
- Stober T, Johnson GH, Schmitter M. Accuracy of the newly formulated vinyl siloxanether elastomeric impression material. J Prosthet Dent 2010;103:228-39. https://doi.org/10.1016/S0022-3913(10)60035-2
- Donovan TE, Chee WW. A review of contemporary impression materials and techniques. Dent Clin North Am 2004;48:vi-vii, 445-70.
- Luthardt RG, Walter MH, Weber A, Koch R, Rudolph H. Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial. Int J Prosthodont 2008;21:322-7.
- Bomberg TJ, Hatch RA, Hoffman W Jr. Impression material thickness in stock and custom trays. J Prosthet Dent 1985;54:170-2. https://doi.org/10.1016/0022-3913(85)90278-1
- Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J. Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 2010;38:553-9. https://doi.org/10.1016/j.jdent.2010.03.015
Cited by
- Final Retention of Recemented Dental Casting Luted with Different Resin Cements vol.32, pp.1, 2017, https://doi.org/10.30699/jidai.32.1.2.1