• 제목/요약/키워드: Third harmonic current

검색결과 55건 처리시간 0.026초

Single stage PFC flyback 컨버터의 전해커패시터용량저감기법 (The Method of Reducing the Output Electrolytic Capacitance in Single Stage PFC flyback Converter)

  • 김진구;박종연
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.81-88
    • /
    • 2015
  • LED has been great attentions in lighting industry because of its long life-time, high efficiency, excellent light output characteristics. However, the life-time of the LED driving system is decreased because of the electrolytic capacitor which is used in the power conversion system for driving LED lighting. Therefore the capacitance reduction methods have been studied to replace an electrolytic capacitor with film or tantalum capacitor. This paper presents the Single stage PFC flyback converter with the simplified third harmonic current injection circuit to reduce output capacitance and the proposed system is theoretically analyzed and verified through the experiment.

K 밴드 FET 주파수 3체배기 설계 (The Design of FET Frequency Tripler for K Band)

  • 배성호;전영훈;윤상원
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.322-325
    • /
    • 2003
  • A 7/21GHz frequency tripler, using a commercially available packaged pHEMT, was designed and fabricated on 15mil RO3003 substrate. Frequency conversion is realized using the third harmonic current of an class B amplifier with rejection feedback at fundamental with optimum load conductance at the third harmonic. The fabricated frequency tripler has achieved a conversion loss of 0.7dB for an input power of 0dBm at 21GHz. The experimental results show good agreement with the harmonic balance simulation.

  • PDF

누설전류측정에 의한 피뢰기 열화진단기술에 있어 전원고조파의 영향 (Influence of System Voltage Harmonics on Arrester Deterioration Diagnostic Techniques by Leakage Current Measurement)

  • 길경석;한주섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2002
  • This paper describes an influence of system voltage harmonics on arrester deterioration diagnostic techniques based on leakage current measurement because the resistive current is composed of two components caused by nonlinear characteristics of arrester and by system voltage harmonics. Resistive leakage currents of arresters, which can be evaluated by the third harmonic component of total leakage currents, increase with its deterioration progress. In this paper, we developed a PSpice model for ZnO arrester to simulate the harmonics' effect described above. In simulation, pure sinusoidal voltage and the $3^{rd}$ harmonic voltage are applied to the model, and the leakage current changes are compared. The simulation results showed that the magnitudes of resistive leakage current depend not only on the phase of system voltage harmonics but also on the magnitude of it.

  • PDF

Transmission-Line Transformer와 Harmonic Filter를 이용한 13.56 MHz 고효율 전류 모드 D급 전력증폭기 설계 (Design of High-Efficiency Current Mode Class-D Power Amplifier Using a Transmission-Line Transformer and Harmonic Filter at 13.56 MHz)

  • 서민철;정인오;이휘섭;양영구
    • 한국전자파학회논문지
    • /
    • 제23권5호
    • /
    • pp.624-631
    • /
    • 2012
  • 본 논문은 Guanella의 1:1 transmission-line transformer와 harmonic filtering 방식을 이용한 13.56 MHz 고효율 전류 모드 D급(CMCD) 전력증폭기를 제안한다. 출력 정합 네트워크에 기존의 D급 전력증폭기의 부하 네트워크를 변형하여 harmonic filtering 방식을 포함시킴으로써 낮은 2차와 3차 고조파 특성을 얻었다. 제작된 CMCD 전력증폭기는 13.56 MHz의 CW 입력 신호를 사용하여 측정하였을 때, 13.4 dB의 전력 이득을 가지며, 44.4 dBm의 출력에서 84.6 %의 높은 PAE 특성을 나타내었다. 같은 출력에서 2차 3차 고조파는 각각 -50.3 dBc와 -46.4 dBc를 나타냈다.

제3 고조파 전류성분의 영향을 고려한 5상 농형 유도전동기의 벡터제어 시스템 (A Vector Control System for Five-Phase Squirrel-Cage Induction Motor Considering Effects of 3rd Current Harmonics Component)

  • 김민회;김남훈
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.206-213
    • /
    • 2012
  • This paper propose a improved speed control system for five-phase squirrel-cage induction motor(IM) considering effects of 3rd. harmonic current components with field oriented control(FOC) A five-phase IM drives present unique characteristics due to the additional degrees of freedom and also drives possess many others advantage compared with the traditional three-phase motor drive system, such as reducing a amplitude of torque pulsation at low frequency and increasing the reliability. In order to maximize the torque per ampere, the proposed motor has concentrated windings. The produced back-electromotive force is almost trapezoidal, and the motor is supplied with the combined sinusoidal plus third harmonic of currents. There is necessary to controlled 3rd harmonic current. For presenting the superior performance of the proposed the speed control system, experimental results are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[KW] induction motor.

Harmonic Winding Factors and MMF Analysis for Five-phase Fractional-slot Concentrated Winding PMSM

  • Kang, Huilin;Zhou, Libing;Wang, Jin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.20-26
    • /
    • 2014
  • To enhance torque density by harmonic current injection, optimal slot/pole combinations for five-phase permanent magnet synchronous motors (PMSM) with fractional-slot concentrated windings (FSCW) are chosen. The synchronous and the third harmonic winding factors are calculated for a series of slot/pole combinations. Two five-phase PMSM, with general FSCW (GFSCW) and modular stator FSCW (MFSCW), are analyzed and compared in detail, including the stator structures, star of slots diagrams, and MMF harmonic analysis based on the winding function theory. The analytical results are verified by finite element method, the torque characteristics and phase back-EMF are also taken into considerations. Results show that the MFSCW PMSM can produce higher average torque, while characterized by more MMF harmonic contents and larger ripple torque.

제3 고조파 전류성분 주입에 의한 5상 농형 유도전동기의 속도제어 특성 (A Speed Control Characteristics for Five-Phase Squirrel-Cage Induction Motor Injecting 3rd Current Harmonics Component)

  • 김민회;김남훈
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.279-288
    • /
    • 2013
  • This paper proposes a improved speed control system for five-phase squirrel-cage induction motor(IM) injecting 3rd. current harmonic components with field oriented control (FOC) A five-phase IM drives present unique characteristics due to the additional degrees of freedom and also drives possess many others advantage compared with the traditional three-phase motor drive system, such as reducing a amplitude of torque pulsation at low frequency and increasing the reliability. In order to maximize the torque per ampere, the proposed motor has concentrated windings. The produced back-electromotive force is almost trapezoidal, and the motor is supplied with the combined sinusoidal plus third harmonic of currents. There is necessary to controlled 3rd harmonic current in order to high response characteristics. For presenting the superior performance of the proposed the speed control system, experimental results are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[kW] induction motor.

Series Active Power Filters to Compensate Harmonics and Reactive Power with the Direct Compensating Voltage Extraction Method in Three-Phase Four-Wire Systems

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.691-699
    • /
    • 2009
  • This paper presents the analysis of series active power filter for reactive power compensation, load balancing, harmonic elimination, and neutral current eradication in three-phase four-wire power systems. Generally, the three-phase four-wire system is widely employed in distributing electric energy to several office building and manufacturing plants. In such systems, the third harmonic and its 3rd harmonics are termed as triple and zero sequence components that do not cancel each other in the system neutral. Consequently, the triple harmonics add together creating a primary source of excessive neutral current. Regarding this concern, this paper presents a new control algorithm for a series hybrid active system, whereas the control approach it adopts directly influence its compensation characteristics. Hence, the advantage of this control algorithm is the direct extraction of compensation voltage reference without phase transformations and multiplying harmonic current value by gain and the required rating of the series active filter is much smaller than that of a conventional shunt active power filter. In order to show the effectiveness of the proposed control algorithm, experiments have been carried out.

Plasmon Assisted Deep-ultraviolet Pulse Generation from Amorphous Silicon Dioxide in Nano-aperture

  • Lee, Hyunsu;Ahn, Heesang;Kim, Kyujung;Kim, Seungchul
    • Current Optics and Photonics
    • /
    • 제2권4호
    • /
    • pp.361-367
    • /
    • 2018
  • Ultrafast deep-ultraviolet (DUV) pulse generation from the subwavelength aperture of a plasmonic waveguide was investigated. The plasmonic nanofocusing of near-infrared (NIR) pulses was exploited to enhance DUV photoemission of surface third harmonic generation (STHG) at the amorphous $SiO_2$ dielectric. The generated DUV pulses which are successfully made from a nano-aperture using 10 fs NIR pulses have a spectral bandwidth of 13 nm at a carrier wavelength of 266 nm. This method is applicable for tip-based ultrafast UV laser spectroscopy of nanostructures or biomolecules

고조파가 누전차단기에 미치는 영향 (Effect of Harmonics on Residual Current Protective Devices)

  • 전정채;이상익;유재근
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.84-89
    • /
    • 2006
  • 고조파에 의한 누전차단기 동작이 계속적으로 보고되어 왔으나 누전차단기 동작을 설명할 수 있는 자료가 없는 실정이다. 본 논문에서는 누전차단기에 대한 고조파 영향을 규명하기 위해 누전차단기 오동작 현황에 대한 조사 및 누전차단기 원인불명 동작이 자주 발생하는 건물에서 고조파를 측정 및 분석하였다. 또한 왜곡된 파형을 발생시킬 수 있는 고조파 합성장치를 이용하여 누전차단기 동작 특성을 시험하였다. 시험결과 3차 고조파가 기본파에 합성되었을 때 가장 작은 값의 누설전류에 누전 차단기가 동작되었고 기본파에 더해진 고조파 차수가 증가할 수 록 누전차단기 동작전류는 증가하였다.