• Title/Summary/Keyword: Thickness ratio effect

Search Result 1,080, Processing Time 0.035 seconds

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

Effect of Biopsy Technique on the Survival Rate of Malignant Melanoma Patients

  • Yamashita, Yutaro;Hashimoto, Ichiro;Abe, Yoshiro;Seike, Takuya;Okawa, Katsumasa;Senzaki, Yuichi;Murao, Kazutoshi;Kubo, Yoshiaki;Nakanishi, Hideki
    • Archives of Plastic Surgery
    • /
    • v.41 no.2
    • /
    • pp.122-125
    • /
    • 2014
  • Background Cutaneous malignant melanoma has a poor prognosis. The detrimental effect of incisional biopsies on the outcome of malignant melanoma has been debated. The aim of this study was to determine the effect of the presence and type of biopsy on the prognosis of malignant melanoma. Methods The medical records of 109 malignant melanoma patients treated at Tokushima University Hospital from 1983 to 2007 were reviewed. After excluding 28 cases with stage 0 disease or incomplete data, 81 cases were analyzed in detail with respect to patient sex, age, tumor site, clinical stage at diagnosis, presence of ulceration or lymph node metastasis, and prognosis. The five-year survival and five-year disease-free survival rates of patients who underwent incisional or excisional biopsies were compared with those who did not undergo a biopsy. Results The male-to-female ratio was 1:1.19. The mean age was 61.3 years (range, 19-93 years). The most common site was a lower extremity, and the most common clinical stage was stage II. No significant differences in clinicopathological features, five-year survival rates, and five-year disease-free survival rates were observed among the three groups. Conclusions The presence and type of biopsy neither affected the metastatic rate nor the prognosis of malignant melanoma. The use of incisional biopsies is not encouraged because tumor thickness cannot be measured accurately. However, they may be helpful for confirming the diagnosis if an excisional biopsy cannot be performed.

Corrosion Fatigue Cracking Propagation Characteristics and its Protection for the AL-Alloys of Shipbuilding (선박용 알루미늄 합금재의 부식피로균열 진전특성과 그 억제에 관한 연구)

  • Lim, Uh-Joh;Kim, Soo-Byung;Lee, Jin-Yel
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.25 no.2
    • /
    • pp.87-104
    • /
    • 1989
  • Recently, with the tendency of more lightening, high-strength and high-speed in the marine industries such as marine structures, ships and chemical plants, the use of the aluminium Alloy is rapidly enlarge and there occurs much interest in the study of corrosion fatigue crack characteristics. In this paper, the initiation of surface crack and the propagation characteristics on the base metal and weld zone of 5086-H116 Aluminium Alloy Plate which is one of the Al-Mg serious alloy(A5000serious) used most when building the special vessels, were investigated by the plane bending corrosion fatigue under the environments of marine, air and applying cathodic protection. The effects of various specific resistances on the initiation, propagation behavior of corrosion fatigue crack and corrosion fatigue life in the base metal and heat affected zone were examined and its corrosion sensitivity was quantitatively obtained. The effects of corrosion on the crack depth in relation to the uniform surface crack length were also investigated. Also, the structural, mechanical and electro-chemical characteristics of the metal at the weld zone were inspected to verify the reasons of crack propagation behavior in the corrosion fatigue fracture. In addition, the effect of cathodic protection in the fracture surface of weld zone was examined fractographically by Scanning Electron Microscope(S.E.M.). The main results obtained are as follows; (1) The initial corrosion fatigue crack sensitibity under specific resistance of 25Ω.cm% show 2.22 in the base metal and 19.6 in the HEZ, and the sensitivity decreases as specific resistance increases (2) By removing reinforcement of weldment, the initiation and propagation of corrosion crack in the HAZ are delayed, and corrosion fatigue life increases. (3) As specific resistance decreases, the sensitivity difference of corrosion fatigue life in the base metal and HAZ is more susceptible than that of intial corrosion fatigue crack. (4) Experimental constant, m(Paris' rule) in the marine environment is in the range of about 3.69 to 4.26, and as specific resistance increases, thje magnitude of experimental constant, also increases and the effect by corrosion decreases. (5) Comparing surface crack length with crack depth, the crack depth toward the thickness of specimen in air is more deeply propagated than that in corrosion environment. (6) The propagation particulars of corrosion fatigue crack for HAZ under initial stress intensity factor range of $\Delta$k sub(li) =27.2kgf.mm super(-3/2) and stress ratio of R=0 shows the retardative phenomenon of crack propagation by the plastic deformation at crack tip. (7) Number of stress cycles to corrosion fatigue crack initiation of the base metal and the welding heat affected zone are delayed by the cathodic protection under the natural sea water. The cathodic protection effect for corrosion fatigue crack initiation is eminent when the protection potential is -1100 mV(SCE). (8) When the protection potential E=-1100 mV(SCE), the corrosion fatigue crack propagation of welding heat affected zone is more rapid than that of the case without protection, because of the microfissure caused by welding heat cycle.

  • PDF

Effect of Acoustic Emission During a Fatigue Test with Defect for Type II Gas Cylinder (피로시험시 발생하는 음향방출신호를 이용한 Type II Gas Cylinder의 손상평가)

  • Jee, Hyun-Sup;Lee, Jong-O;Ju, No-Hoe;So, Cheal-Ho;Lee, Jong-Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • This research seeks to evaluate damage on type II gas cylinder by an acoustic emission test when executing 20000 cycles fatigue test and thereafter burst test. Used gas cylinders in the experimental are three types as follows; one is sound cylinder, others are cylinders which contain longitudinal and transverse artificial defect. The size of artificial defect is a depth of 3 mm, width of 3 mm and length of 50 mm. In the case of the cylinder which artificial defect, unlike the expectation that it will burst in low pressure, the burst pressure of the cylinder did not differ much according to whether or not there were defects. However, when there was longitudinal defect, the location of burst was near the location of defect. This leads to the effect in which the thickness of the composite material becomes thinner according to the length of the longitudinal defect and this is judged to have an effect on the location of initiation and growth of crack in the liner. Also, for the acoustic emission signal, when there is longitudinal defect, the ratio of an event occurring at defect position among overall hits is more than 50 %, and the source location also accords very precisely with defect position.

Lodging Related Traits of Rice Plants as Affected by ′KIM -112′ Application (KIM-112 처리가 벼 도복관련형질에 미치는 영향)

  • Choi, Chung-Don;Kim, Soon-Chul;Lee, Soo-Kwan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.3
    • /
    • pp.218-223
    • /
    • 1990
  • This experiment was carried out to obtain basic information on the lodging characteristics and yield components of rice plants by new anti-lodging reagent 'KIM-112' (3%, Wp) application at 30 days before heading (DBH) to 5 DBH under two dosage levels (lg 2g, a. i. /10a) at the Yeongnam Crop Experiment Station in 1989. Culm length was shortened by 10-17% at 1g, a. i. /10a and by 16-23% at 2g of KIM -112 applications. The shortening effect of internode was different by dosages and application times: 2g treatment was greater effect than 19 and early application resulted in shortening of lower internode while this was upper internode at the late application. There were positive correlation between culm length and lodging index, the 1st and the 4th internode lengths had on important effect to lodging index. Thickness of culm wall, culm diameter and weight of basal part of culm were not affected by KIM-112 application. However anti-lodging characters improved by increasing the breaking weight and by decreasing the moment. Lodging index was related to breaking weight, moment and weight of panicle. Heading date by KIM-112 application was delayed one to four days and number of grains per panicle was decreased by shortened panicle length as compared with untreated control, but yield capacity was high a little because of improvement ripening ratio by no lodging.

  • PDF

Fabrication and Characteristics of Zinc Oxide- and Gallium doped Zinc Oxide thin film transistor using Radio Frequency Magnetron sputtering at Room Temperature (Zinc Oxide와 갈륨이 도핑 된 Zinc Oxide를 이용하여 Radio Frequency Magnetron Sputtering 방법에 의해 상온에서 제작된 박막 트랜지스터의 특성 평가)

  • Jeon, Hoon-Ha;Verma, Ved Prakash;Noh, Kyoung-Seok;Kim, Do-Hyun;Choi, Won-Bong;Jeon, Min-Hyon
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.359-365
    • /
    • 2007
  • In this paper we present a bottom-gate type of zinc oxide (ZnO) and Gallium (Ga) doped zinc oxide (GZO) based thin film transistors (TFTs) through applying a radio frequency (RF) magnetron sputtering method at room temperature. The gate leakage current can be reduced up to several ph by applying $SiO_2$ thermally grown instead of using new gate oxide materials. The root mean square (RMS) values of the ZnO and GZO film surface were measured as 1.07 nm and 1.65 nm, respectively. Also, the transmittances of the ZnO and GZO film were more than 80% and 75%, respectively, and they were changed as their film thickness. The ZnO and GZO film had a wurtzite structure that was arranged well as a (002) orientation. The ZnO TFT had a threshold voltage of 2.5 V, a field effect mobility of $0.027\;cm^2/(V{\cdot}s)$, a on/off ratio of $10^4$, a gate voltage swing of 17 V/decade and it operated in a enhancement mode. In case of the GZO TFT, it operated in a depletion mode with a threshold voltage of -3.4 V, a field effect mobility of $0.023\;cm^2/(V{\cdot}s)$, a on/off ratio of $2{\times}10^4$ and a gate voltage swing of 3.3 V/decade. We successfully demonstrated that the TFTs with the enhancement and depletion mode type can be fabricated by using pure ZnO and 1wt% Ga-doped ZnO.

The Effects of Bogimakseong-bang(補氣膜性方) Treatment on cBSA-induced Membranous Nephropathy in Mouse Model (보기막성방(補氣膜性方)이 Cationized Bovine Serum Albumin투여로 유발된 Mouse의 Membranous Nephropathy에 미치는 영향)

  • Lee, Jung-Won;Cho, Chung-Sik;Kim, Cheol-Jung
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.1083-1099
    • /
    • 2008
  • Objective : We aimed to identify the effects of Bogimakseong-bang(BGMSB) treatment on cBSA-induced MN in a mouse model. Methods : We divided 20 mice into 4 groups. The normal group (NR) had no treatment. We used cBSA to induced MN to the other 3 groups. One group (CT) was treated with cBSA (7mg/kg i.p) only. The second (BG-250) was treated with cBSA (7mg/kg i.p) and BGMSB extract (250mg/kg, p.o). The third group (BG-500) was treated with cBSA(7mg/kg i.p) and BGMSB extract (500mg/kg, p.o). After cBSA and BGMSB extract treatment for 4 weeks, proteinuria, serum albumin, total cholesterol, serum creatinine, BUN, total nucleated spleen cell number and total infiltrated kidney cell number of all groups were measured. CD3e+/CD19+ and CD4+/CD8 cells ratio of peripheral blood, kidney and spleen of all groups were analyzed. $IL-1{\beta}$ and $TNF-{\alpha}$, IL-6, IgG, IgM, and $IFN-{\gamma}$ levels of all groups were gauged. Histological analysis of kidney tissue and immunohistochemical staining (CD4 CD8) of kidneys were observed. Results : Proteinuria significantly decreased and serum albumin increased in groups treated with cBSA and BGMSB extract compared with the control. Total cholesterol decreased but not significantly. CD3e+/CD19cells ratio of peripheral blood decreased. CD3e+/CD19+ and CD4+/CD8 cells percentage of kidney and spleen showed no significant change. Level of $IL-1{\beta}$, $TNF-{\alpha}$ and IL-6 significantly decreased. and $IFN-{\gamma}$ increased but has not significantly. Concentration of IgG and IgM significantly decreased compared with control. Thickness of GBM decreased on histological analysis of kidney. Deposition of CD4 and CD8 decreased on immunohistochemical staining of kidney. Conclusions : According to the above result, BGMSB had a significant effect for treating MN which is cBSA-induced.

  • PDF

A Study on the Compression Moldability for Continuous Fiber-Reinforced Polymeric Composites -Part II : Effect of Correlation Coefficient on Compression Moldability- (연속섬유강화 플라스틱 복합재료의 압축성형성에 관한 연구 -제II보 : 압축성형성에 미치는 상관계수의 영향-)

  • 오영준;김이곤
    • Composites Research
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 2000
  • During the compression molding process of the continuous fiber-reinforced polymeric composites, two main problems such as fiber-matrix separation and fiber orientation are produced by the difference of flow velocity. Molded parts are lead to be nonhomogeneous and anisotropic. As the mechanical property of the products are dependent on the separation and orientation, it is important to research the fiber mat structure and molding condition. If the fiber mat structure is changed by the increment of needling, the separation decreases and after compression molding the orientation is easily aligned. As it were, the compression moldability is good. But the defects as tears, thin thickness are produced in the products. Therefore, it is important to clarify the moldability in relation to the usage of products and the expenses of produce on the actual process. Therefore we must make the measurement methods that can define the moldability of products. In this research, the effects of the fiber mat structure(NP = 0, 5, 10, 25, 50 punches/$cm^2$) and the mold geometry($r_p$ = 1, 25, 50 mm) on the moldability of products were discussed. We investigated the case of one-dimensional flow in order to obtain the degree of nonhomogeneity and the fiber orientation function. In result, we could gain the correlation coefficient of the continuous fiber-reinforced polymeric composites. Also we experimented on the cup-type compression molding which was appeared the wrinkle on the flange part by the complex stress condition in order to gain the degree of nonhomogeneity and area ratio. In result, the moldability of products was expressed as the correlation coefficient and area ratio.

  • PDF

Bearing Capacity of Shallow Foundation on a Finite Layer of Sandy Ground Underlain by a Rigid Base (강성저면위 유한한 두께의 모래지반에 놓인 얕은기초의 지지력)

  • Jun, Sang-Hyun;Yoo, Nam-Jae;Yoo, Kun-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.6
    • /
    • pp.39-48
    • /
    • 2011
  • In this paper the method of estimating the bearing capacity of shallow foundation on a finite layer of sandy ground underlain by a rigid base was proposed by assessing results of the model test and the numerical analyses. For model experiments, the centrifuge tests under 1g and 20 g of gravitational levels were performed with sandy soils sampled from the field, changing the relative density of sandy soil and the ratio of thickness of sand layer (H) to the width of strip footing (B). As results of tests, bearing capacity tends to increase with the value of H/B while settlement for a given load intensity decreases. Bearing capacity also increases with relative density of the soil. In order to propose the method of estimating the bearing capacity of thin sandy layer underlain by a rigid base, values of bearing capacity factors from test results were compared with the values of modified bearing capacity factor by Mandel & Salencon (1972) considering the effect of H/B value on bearing capacity. The relation of bearing capacity factor ratio, normalizing friction angle of sandy soil, with the value of H/B was suggested so that this relation could be applied to design in the safe side. The results of numerical analyses obrained by changing the layout of footing, relative density of sandy soil and the value of H/B, were in good agreements with the suggested relation.

Enhancement of peri-implant bone formation via parathyroid hormone administration in a rat model at risk for medication-related osteonecrosis of the jaw

  • Park, Ji Young;Heo, Hyun A;Park, Suhyun;Pyo, Sung Woon
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.121-131
    • /
    • 2020
  • Purpose: Dental implant-associated medication-related osteonecrosis of the jaw has been frequently reported in patients administered bisphosphonates (BPs) to prevent osteoporosis. The aim of this study was to investigate the effect of intermittent administration of parathyroid hormone (PTH) on peri-implant bone in the maxillae of ovariectomized rats systemically administered BPs. Methods: Thirty 8-week-old female Sprague-Dawley rats were randomly divided into 3 groups. The OVX-ZP group included ovariectomized rats administered 60 ㎍/kg of zoledronate once a week for 6 weeks and 30 ㎍/kg PTH after implant installation. The OVX-Z group included ovariectomized rats administered 60 ㎍/kg of zoledronate once a week for 6 weeks and saline after implant installation, and the control group included rats that underwent a sham operation and were then administered saline. Rats were sacrificed 4 weeks after implant placement for histomorphometric and micro-computed tomography (CT) analyses. Results: The average bone area percentage was greater in the OVX-ZP group than in the OVX-Z group (53.4%±4.0% vs. 28.9%±9.5%, P=0.01). The bone-to-implant contact ratio was 50.8%±1.4% in the OVX-ZP group and 16.9%±2.4% in the OVX-Z group (P=0.012). The average bone volume ratio as shown on micro-CT was 31.3%±19.8% in the OVX-ZP group and 19.4%±9.3% in the OVX-Z group (P=0.045). The OVX-ZP and OVX-Z groups displayed similar trabecular thickness (0.06±0.004 mm vs. 0.06±0.002 mm) (P>0.05) and trabecular separation (0.21±0.02 mm vs. 0.29±0.13 mm) (P>0.05). However, the number of trabeculae in the OVX-ZP group was significantly higher than that in the OVX-Z group (4.3±1.33/㎣ vs. 2.2±0.19/㎣) (P=0.024). Conclusions: The present findings indicate that intermittently-administered PTH can promote peri-implant bone formation and suggest that PTH administration may aid in effective treatment for medication-related osteonecrosis of the jaw after dental implantation.