• 제목/요약/키워드: Thickness Change

검색결과 2,306건 처리시간 0.03초

Comparison of the Thickness of the Neck Flexor Muscles of Subjects With and Without a Forward Head Posture on the Two Initial Head Positions During Cranio-Cervical Flexion Exercise

  • Jung, Sung-hoon;Kwon, Oh-yun;Choi, Kyu-hwan;Ha, Sung-min;Kim, Su-jung;Jeon, In-cheol;Hwang, Ui-jae
    • 한국전문물리치료학회지
    • /
    • 제22권4호
    • /
    • pp.44-50
    • /
    • 2015
  • This study compared the effects of the initial head position (i.e., a HHP versus a relaxed head position) of subjects with and without a FHP on the thickness of the deep and superficial neck flexor muscles during CCF. The study recruited 6 subjects with a FHP and 10 subjects without a FHP. The subjects performed CCF in two different head positions: a HHP, with the head aligned so that the forehead and chin formed a horizontal line, and a relaxed head position (RHP), with the head aligned in a self-selected comfortable position. During the CCF exercise, the thickness of the longus colli (LCo) and the thickness of the sternocleidomastoid (SCM) were recorded using ultrasonography. The thickness of each muscle was measured by Image J software. The statistical analysis was performed with a two-way mixed-model analysis of variance. The thickness of the SCM differed significantly (p<.05) between the subjects with and without FHP. According to a post $h^{\circ}C$ independent t-test, the change in thickness of the SCM increased significantly during CCF in the subjects with FHP while adopting a HHP compared to that in the subjects without FHP. The change in thickness of the SCM was not significantly different between the two positions in subjects without FHP, and there was no significant change in thickness of the LCo muscle during the CCF exercise according to the initial position in both subjects with and without FHP. The results suggest that CCF should be performed in RHP to minimize contraction of the SCM in subjects with a FHP.

Geant4 전산모사를 이용한 두개골 팬텀의 물질 두께 변동에 따른 양성자 브래그 피크의 위치 변화 (Change of Proton Bragg Peak by Variation of Material Thickness in Head Phantom using Geant4)

  • 김유미;천권수
    • 한국방사선학회논문지
    • /
    • 제15권4호
    • /
    • pp.401-408
    • /
    • 2021
  • 양성자 치료는 방사선치료 중 하나로 브래그 피크로 알려진 물리적 특성을 활용한 방법이다. 양성자 치료계획 수립 시 주로 전산화단층촬영(CT)의 인체 횡단면 영상이 사용되고 있다. CT는 사용되는 관전압에 따라 HU가 변하게 되며 이는 구조물의 경계, 두께 변화로 이어진다. 본 연구는 Geant4를 이용하여 복합 물질로 구성된 두개골 팬텀에서 두께 변화에 따른 뇌 영역의 브래그 곡선의 변화를 살펴보았다. 먼저, 단일 물질로 구성된 팬텀에서 매질의 종류와 양성자의 입사에너지에 따른 브래그 곡선을 측정하여 Geant4 계산결과의 신뢰성을 확보하였다. 두개골 팬텀의 각 두께를 변동하였을 때 뇌 영역에서 발생하는 피크의 위치변화를 측정하였다. 연부조직의 두께를 변화하였을 때 피크의 위치 변화는 나타나지 않았으며, 피부의 두께를 변화하였을 때 피크의 변화는 적었으며, 주로 뼈의 두께를 변화할 때 피크의 위치 변화가 나타났다. 또한 뼈를 단독으로 변화하였을 때와 뼈를 다른 조직과 함께 변화하였을 때 피크의 위치 변화량은 동일하였다. 뼈의 정확한 두께 측정이 방사선치료계획의 선량-깊이 분포 예측에 주요 인자 중 하나임을 확인하였다.

판재의 일축인장 소성불안정에 미치는 두께의 영향 (The Effects of Thickness on the Plastic Instability under Uniaxial Tension in Sheet Metal)

  • 한규택;강대민;구양;백남주
    • 한국정밀공학회지
    • /
    • 제6권2호
    • /
    • pp.58-64
    • /
    • 1989
  • Plastic instability in uniaxial tension of commercial purity Al has been studied with the emphasis of effects of thickness in cold worked specimens and recrystallized specimens. The thickness change gave rise to change in stress state and the amount of strain localization in specimen after diffuse necking. Therefore the thickness of speci- men could control modes of plastic instability. Regardless of recrystallized or cold worked state, the necking mode changed from diffuse necking to local necking, at about 1.5 .approx. 2 mm in thickness.

  • PDF

C5210-H(HP)와 NKT322-EH 소재의 협피치 커텍터에서 단조 가공에 의한 소재 폭 변화에 관한 연구 (A study on the change of material width by forging processing in fine pitch connector of C5210-H(HP) and NKT322-EH materials)

  • 신미경;이춘규
    • Design & Manufacturing
    • /
    • 제14권3호
    • /
    • pp.17-22
    • /
    • 2020
  • As devices such as smartphones, tablet PC, and wearable devices have been miniaturized, the connectors that go into the devices are also designed to be very small. The connector combines the plug and the receptacle to transfer electricity. As devices are miniaturized, the contact shape is formed by partially thinning the thickness of the raw material of the terminal in order to lower the coupling height of the plug and receptacle. The product used in this study is a receptacle terminal used for 0.4mm pitch board to board connector among fine pitch connectors. When the material thickness is reduced by forging the receptacle terminal, the width change of the pin is checked. To reduce the thickness of the material by forging, pre-notching is applied in the first step, forging in the second step, and notching in the third step. After forming the width dimension of the pin to 0.28 mm in the pre-notching process, in the forging process, the material thickness 0.08 mm and 0.02 mm (25%) were forged and the thickness was changed to 0.06 mm and the width change amount of the pin was measured. The facility produced 10,000 pieces at 400 SPM using a Yamada Dobby (MXM-40L) press, and thirty pins were measured and the average value was shown. After forging by using C5210-H (HP) and NKT322-EH, which are frequently used in connectors, analyze the amount of change in each material. The effect of punching oil on forging is investigated by appling FM-200M, which is highly viscous, and FL-212, fast drying oil. This study aims to minimize mold modification by predicting the amount of material change after forging.

치밀골 두께 변화에 따른 임플랜트 1차안정성과 즉시하중부담능 평가 (AN EVALUATION OF THE PRIMARY IMPLANT STABILITY AND THE IMMEDIATE LOAD-BEARING CAPACITY ACCORDING TO THE CHANGE OF CORTICAL BONE THICKNESS)

  • 이양진;박찬진;조리라
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.248-257
    • /
    • 2005
  • Statement of problem. Cortical bone plays an important role in the primary implant stability, which is essential to immediate/early loading. However, immediate load-bearing capacity and primary implant stability according to the change of the cortical bone thickness have not been reported. Purpose. The objectives of this study were (1) to measure the immediate load-bearing capacity of implant and primary implant stability according to the change of cortical bone thickness, and (2) to evaluate the correlation between them. Material and methods.48, screw-shaped implants (3.75 mm$\times$7 mm) were placed into bovine rib bone blocks with different upper cortical bone thickness (0-2.5 mm) and resonance frequency (RF) values were measured subsequently. After fastening of healing abutment. implants were subjected to a compressive load until tolerated micromotion threshold known for the osseointegration and load values at threshold were recorded. Thereafter, RF measurement after loading, CT taking and image analysis were performed serially to evaluate the cortical bone quality and quantity. Immediate load-bearing capacity and RF values were analyzed statistically with ANOVA and post-hoc method at 95% confidence level (P<0.05). Regression analysis and correlation test were also performed. Results. Existence and increase of cortical bone thickness increased the immediate load-bearing capacity and RF value (P<0.05) With the result of regression analysis, all parameter's of cortical bone thickness to immediate load-bearing capacity and resonance frequency showed significant positive values (P<0.0001). A significant high correlation was observed between the cortical bone thickness and immediate load-beating capacity (r=0.706, P<0.0001), between the cortical bone thickness and resonance frequency (r=0.753, P<0.0001) and between the immediate load-bearing capacity and resonance frequency (r=0.755, P<0.0001). Conclusion. In summary, cortical bone thickness change affected the immediate load-baring capacity and the RF value. Although RF analysis (RFA) is based on the measurement of implant/bone interfacial stiffness, when the implant is inserted stably, RFA is also considered to reflect implant/bone interfacial strength of immediately after placement from high correlation with the immediate load-baring capacity. RFA and measuring the cortical bone thickness with X-ray before and during surgery could be an effective diagnosis tool for the success of immediate loading of implant.

연속압연기에서 OFF GAUGE 저감을 위한 DYNAMIC SET-UP 제어기술 (DYNAMIC SET-UP CONTROL OF TANDEM COLD MILL)

  • 노호섭;최병조;조뇌하;이재훈;김익준;진철제;박기영
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.126-131
    • /
    • 1999
  • In order to reduce the length of off-gauge at FGC(Flying gauge change) point, We adopted dynamic set up in No. 4 cold rolling mill. The conventional set-up of FGC(Flying gauge change) was calculated on the basis of preset values in the process control computer, so the difference between actual strip thickness and preset thickness cause long off-gauge. The dynamic SET-UP control was calculated on the basis of actual strip thickness of FGC(Flying gauge change) point from X-ray gauge of mill entry and No.i stand. We applied dynamic SET-UP control in September last year. Compare to the previous result, the length of off-gauge is reduced by about 36%.

  • PDF

PdHx 박막의 두께 변화에 의한 전기비저항의 온도 의존성 변화 (Temperature Dependence Change of Electrical Resistivity on PdHx Films due to Film Thickness Change)

  • 조영신
    • 한국수소및신에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.17-22
    • /
    • 1995
  • Thermally evaporated Pd films on substrate were hydrogenated upto 1 bar of hydrogen gas at room temperature. Temperature dependence hange of electrical resistivity on Pd films is examined in the thickness range between $60{\AA}$ and $990{\AA}$. Resistivity of Pd is fitted well with Bloch-$Gr{\ddot{u}}neisen$ formula. Debye temperatures of Pd films are about 254 K, which are 20 K lower than that of bulk Pd. Debye temperature is not sensitive to film thickness change. Temperature of substrate during evaporation changes temperature dependence of resistivity of films much. Optical phonon contribution increases with decreasing temperature of PdHx.

  • PDF

MoS2 두께 변화에 따른 MoS2/p-Si 광센서 특성 연구 (MoS2 Thickness-Modulated MoS2/p-Si Photodetector)

  • 김홍식;김준동
    • Current Photovoltaic Research
    • /
    • 제5권4호
    • /
    • pp.145-149
    • /
    • 2017
  • Transition metal dichalcogenides (TMDs) have attracted much attention because of their excellent optical and electrical properties, which are the applications of next generation photoelectric devices. In this study, $MoS_2$, which is a representative material of TMDs, was formed by magnetic sputtering method and surface changes and optical characteristics were changed with thickness variation. In addition, by implementing the photodetector of $MoS_2/p-Si$ structure, it was confirmed that the change of the electrical properties rather than the change of the optical properties according to the thickness change of $MoS_2$ affects the photoresponse ratio of the photodetector. This result can be used to fabricate effective photoelectric devices using $MoS_2$.

안정화 운동과 근력운동이 비특이성 요통환자의 통증, 관절가동범위, 근력, 근 두께에 미치는 영향 (The Effect of Stabilization Exercise and Strength Exercise on Pain, ROM, Strength, Muscle Thickness of Non-Specific Low Back Patients)

  • 정찬주;양회송;유영대;노현준;장윤형;문경애;이윤경;임창우;조실금
    • 대한통합의학회지
    • /
    • 제2권1호
    • /
    • pp.35-49
    • /
    • 2014
  • Purpose : The purpose of this study was to find the effects of the lumbar stabilization exercise and strength exercise on pain, ROM, strength, muscle thickness of low back pain(LBP) patients. Method : The subjects were consisted of twelve patients who had nonspecific LBP. All subjects randomly assigned to lumbar stabilization exercise group(N=6) and strength exercise group(N=6). We measured muscular strength, ROM by using Tergumed-extension, rotation and muscle thickness by using ultrasonography and pain score by using Visual analog scale(VAS). The lumbar stabilization exercise group received TOGU exercise, strength exercise group received Tergumed exercise. The data analyzed by repeated measure of Independent t-test, paired t-test, reliability test. Result : The results were as follows. The result which measured of the change of pain score was a significant decrease. The result which measured of the change of ROM and strength was a significant increase. The result which measured of the change of the Internal abdominal oblique, External abdominal oblique on muscle thickness was a significant increase. Stabilization exercise group and Strength exercise group showed the significant difference in muscle thickness on Transversus abdominis, Multifidus. Stabilization exercise group was more increased in muscle thickness. Conclusion : Therefore, we suggest that stabilization exercise is effective for non-specific low back pain.

Study on Thickness of Porous Silicon Layer According to the Various Anodization Times

  • 장승현
    • 통합자연과학논문집
    • /
    • 제3권4호
    • /
    • pp.206-209
    • /
    • 2010
  • As the etching time is varied, the change of thickness of the porous silicon layers was successfully investigated. The thickness of the PSi layer as a function of anodization time for a p-type substrate that is etched at a constant current density of 50 $mA/cm^2$ in a 35% hydrofluoric acid solution shows a linear relationship between the etching time and the thickness of the PSi layer.