1 |
Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11(5):491-501
PUBMED
|
2 |
Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol 1997;23(3):104-11
PUBMED
|
3 |
Meredith N, Book K, Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8(3):226-33
DOI
ScienceOn
|
4 |
Buchs AU, Levine L, Moy P. Preliminary report of immediately loaded Altiva Natural Tooth Replacement dental implants. Clin Implant Dent Relat Res 2001;3(2):97-106
DOI
ScienceOn
|
5 |
De Boever JA, McCall WD Jr, Holden S, Ash MM Jr. Functional occlusal forces: an inves-tigation by telemetry J Prosthet Dent. 1978:40(3):326-33
DOI
ScienceOn
|
6 |
Wolfinger GJ, Balshi TJ, Rangert B. Immediate functional loading of Branemark system implants in edentulous mandibles: Clinical report of the results of developmental and simplified protocols. Int J Oral Maxillofac Implants 2003;18:250-57
|
7 |
Glauser R, Sennerby L, Meredith N, Ree A, Lundgren A, Gottlow J, Hammerle CH. Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clin Oral Implants Res 2004;15(4):428-34
DOI
ScienceOn
|
8 |
Levine R, Rose L, Salama H. Immediate loading of root-form implants: Two case reports 3 years after loading. Int J Periodontics Restorative Dent 1998;18(4):333-43
PUBMED
|
9 |
Watanabe Y, Takai S, Arai Y, Yoshino N, Hirasawa Y. Prediction of mechanical properties of healing fractures using acoustic emission. J Orthop Res 2001;19(4):548-53
DOI
ScienceOn
|
10 |
Gapski R, Wang H, Mascarenhas P, Lang NP. Critical review of immediate implant loading. Clin Oral Impl Res 2003;14:515-27
DOI
ScienceOn
|
11 |
Nkenke E, Lehner B, Weinzierl K, Thams U, Neugebauer J, Steveling H et al. Bone contact, growth, and density around immediately loaded implants in the mandible of mini pigs. Clin Oral Inpl Res 2003;14:312-21
DOI
ScienceOn
|
12 |
Sennerby L, Thomsen P, Ericson LE. A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone. Int J Oral Maxillofac Implants 1992;7(1):62-71
|
13 |
Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res 1998;43(2):192-203
DOI
ScienceOn
|
14 |
Friberg B, Sennerby L, Linden B, Grondahl K. Lekholm U. Stability measurements of onestage Branemark implants during healing in mandibles. A clinical resonance frequency analysis study. Int J Oral Maxillofac Surg 1999;28(4):266-72
DOI
PUBMED
ScienceOn
|
15 |
Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999:28(4):297-303
DOI
PUBMED
ScienceOn
|
16 |
Bischof M, Nedir R, Szmukler-Moncler S, Bernard JP, Samson J. Implant stability measurement of delayed and immediately loaded implants during healing. Clin Oral Implants Res 2004;15(5):529-39
DOI
ScienceOn
|
17 |
Lekholm U, Zarb GA. Patient selection and preparation. In: Branemark PI, Zarb GA, Albrektsson T., eds. Tissue-integrated prostheses: Osseointegration in clinical dentistry. Chicago: Quintessence;1985:199-209
|
18 |
Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implanttissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7(3):261-7
DOI
ScienceOn
|
19 |
Friberg B, Sennerby L, Roos J, Johansson P. Strid CG, Lekholm U. Evaluation of bone density using cutting resistance measurements and microradiography: an in vitro study in pig ribs. Clin Oral Implants Res 1995;6(3):164-71
DOI
ScienceOn
|
20 |
Shahlaie M, Gantes B, Schulz E,Riggs M, Crigger M. Bone density assessmentof dental implant sites: 1. Quantitative computed tomography. Int J Oral Maxillofac Implants 2003;18:224-231
|
21 |
Rho JY, Hobatho MC, Ashman RB. Relations of mechanical properties to density and CT numbers in human bone. Med Eng Phys 1995;17(5):347-55
DOI
ScienceOn
|
22 |
Meredith N, Shagaldi F, Alleyne D, Sennerby L, Cawley P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 1997;8(3):234-43
DOI
ScienceOn
|
23 |
Olsson M, Urde G, Anderson JB, Sennerby L. Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: Results after lyear of loading, case series, Clin Implant Dent Relat Res 2003;5 Sup pl 1:81-5
DOI
ScienceOn
|
24 |
Niimi A, Ozeki K, Ueda M, Nakayama B. A comparative study of removal torque of endosseous implants in the fibula, iliac crest and scapula of cadavers: preliminary report. Clin Oral Implants Res 1997;8(4):286-9
DOI
ScienceOn
|
25 |
Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP. Samson J. Predicting osseoin-tegration by means of implant primary stability. Clio Oral Implants Res 2004;15(5):520-8
DOI
ScienceOn
|
26 |
Nikellis I, Levi A, Nicolopoulos C. Immediate loading of 190 endosseous dental implants: a prospective observational study of 40 patient treatments with up to 2-year data. lnt J Oral Maxillofac Implants 2004;19(1):116-23
|