• 제목/요약/키워드: Thermoplastic Resin

검색결과 114건 처리시간 0.022초

Color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for non metal clasp denture

  • Jang, Dae-Eun;Lee, Ji-Young;Jang, Hyun-Seon;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.278-287
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the color stability, water sorption and cytotoxicity of thermoplastic acrylic resin for the non-metal clasp dentures to those of thermoplastic polyamide and conventional heat-polymerized denture base resins. MATERIALS AND METHODS. Three types of denture base resin, which are conventional heat-polymerized acrylic resin (Paladent 20), thermoplastic polyamide resin (Bio Tone), thermoplastic acrylic resin (Acrytone) were used as materials for this study. One hundred five specimens were fabricated. For the color stability test, specimens were immersed in the coffee and green tee for 1 and 8 weeks. Color change was measured by spectrometer. Water sorption was tested after 1 and 8 weeks immersion in the water. For the test of cytotoxicity, cell viability assay was measured and cell attachment was analyzed by FE-SEM. RESULTS. All types of denture base resin showed color changes after 1 and 8 weeks immersion. However, there was no significant difference between denture base resins. All specimens showed significant color changes in the coffee than green tee. In water sorption test, thermoplastic acrylic resin showed lower values than conventional heat-polymerized acrylic resin and thermoplastic polyamide resin. Three types of denture base showed low cytotoxicity in cell viability assay. Thermoplastic acrylic resin showed the similar cell attachment but more stable attachment than conventional heat-polymerized acrylic resin. CONCLUSION. Thermoplastic acrylic resin for the non-metal clasp denture showed acceptable color stability, water sorption and cytotoxicity. To verify the long stability in the mouth, additional in vitro studies are needed.

TiO2, Carbonblack 및 POE로 보강된 열가소성 PETG 복합재료의 특성 (Characterization of PETG Thermoplastic Composites Enhanced TiO2, Carbon Black, and POE)

  • 유성훈;이종혁;심지현
    • 한국염색가공학회지
    • /
    • 제31권4호
    • /
    • pp.354-362
    • /
    • 2019
  • In order to apply thermoplastic composites using PETG resin to various industrial fields such as bicycle frames and industrial parts, it is necessary to verify the impact resistance, durability and mechanical properties of the manufactured composite materials. To improve the mechanical properties, durability and impact resistance of PETG resin, an amorphous resin, in this study, compound and injection molding process were carried out using various additives such as TiO2, carbon black, polyolefin elastomer, and PETG amorphous resin. The thermal and mechanical properties of the thermoplastic composites, and the Charpy impact strength. The analysis was performed to evaluate the characteristics according to the types of additives. DSC and DMA analyzes were performed for thermal properties, and tensile strength, flexural strength, and tensile strength change rate were measured using a universal testing machine to evaluate mechanical properties. Charpy impact strength test was conducted to analyze the impact characteristics, and the fracture section was analyzed after the impact strength test. In the case of POE material-added thermoplastic composites, thermal and mechanical properties tend to decrease, but workability and impact resistance tend to be superior to those of PETG materials.

Influence of Surface Free Energy of Carbon Black/Thermoplastic Resin Composites on PTC Characteristics

  • Park, Soo-Jin;Kim, Hyun-Chel;Lee, Jae-Rock
    • Carbon letters
    • /
    • 제1권1호
    • /
    • pp.1-5
    • /
    • 2000
  • The effect of surface free energy on the positive temperature coefficient (PTC) of carbon black/thermoplastic resin composites was investigated. The thermoplastic resins such as EVA, LDPE, LLDPE and HDPE were used with the addition of 30 wt.% of the carbon black. The surface free energy of the composites was studied in the context of two-liquid contact angle measurements, i.e., deionized water and diiodomethane. It was observed that the resistivity on PTC composites Was greatly increased near the crystalline melting temperature, due to the thermal expansion of polymeric matrix. From the experimental results, it was proposed that the decrease of surface free energy induced by interactions between carbon black surfaces and polymer chains is an important factor to the fabrication of a PTC composite made of carbon black and polymeric matrix.

  • PDF

구개인두부전증 환자에서 열가소성레진을 이용해 연구개거상장치를 제작한 증례 (Fabrication of palatal lift prosthesis using thermoplastic resin for a patient with velopharyngeal insufficiency)

  • 정현정;김지환;이상휘;박영범
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.286-290
    • /
    • 2016
  • 최근에 열가소성 레진 클라스프를 이용한 가철성 장치의 사용이 빈번해졌다. 통상적으로 사용하는 아크릴릭 레진과 비교했을 때 열가소성 레진은 낮은 굴곡 강도와 탄성률을 가지고 있다. 그러므로 열가소성 레진으로 제작된 가철성 장치는 파절의 위험이 낮아 의치상이 얇고 가볍게 만들어져 환자들이 편하게 사용할 수 있다. 또한 장치가 치아 언더컷에 수동적으로 장착될 수 있어 지대치의 삭제가 최소이거나 거의 없다. 이 증례에서는 경도의 구개인두부전을 가진 44세 여환은 polyester 계열 열가소성 레진으로 제작된 구개거상장치로 치료를 받았다. 환자가 결손치가 없고 보존적인 치료를 원하기 때문에 열가소성 레진을 이용한 가철성 장치가 상대적으로 만족스러운 치료 결과를 보였다.

가압주사식 열가소성 의치상 레진과 이장 레진 간의 결합강도에 관한 연구 (A STUDY ON THE BOND STRENGTH OF RELINE RESIN TO PRESSURE INJECTION TYPE THERMOPLASTIC DENTURE BASE RESIN)

  • 문태성;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제40권1호
    • /
    • pp.42-52
    • /
    • 2002
  • The purpose of this study was to evaluate the bond strength of reline resin to pressure injection type thermoplastic denture base resin. The denture base resins used in this study were $Hi-polycarbonate^{(R)}$(High Dental Co., Japan), Acetal $dental^{(R)}$(Pressingdental s.r.1., Repubblica di San Marine) of thermoplastic resin and Acron $MC^{(R)}$(GC Dental Industrial Co., Japan) of heat cured resin. The reline resins used were Lucitone $199^{(R)}$(Dentsply international Inc., USA), Tokuso $rebase^{(R)}$(Tokuyama Corp., Japan), and $Lightdon-U^{(R)}$(Dreve-Dentamid-Gmbh, Germany). The reline resins are representative of heat-cured, self-cured, and light-cured resin respectively Bond strength was examined by use of a three-point transverse flexural strength test. The results were as follows 1. The bond strength of Lucitone 199 to Acron MC was the highest. 2. The bond strengths of Lucitone 199 and Tokuso rebase to Hi-polycarbonate resulted in a value of approximately one half that of Lucitone 199 to Acron MC and there were no significant differences between these and the bond strength of Tokuso rebase to Acron MC(p<0.05) 3. The bond strengths of reline resins to Acetal dental were lower than those of reline resins to Hi-polycarbonate. 4. For all base resins Lightdon-U showed lower bond strength than the other reline resins.

A new type of clear orthodontic retainer incorporating multi-layer hybrid materials

  • Ahn, Hyo-Won;Kim, Kyung A;Kim, Seong-Hun
    • 대한치과교정학회지
    • /
    • 제45권5호
    • /
    • pp.268-272
    • /
    • 2015
  • Clear thermoplastic retainers have been widely used in daily orthodontics; however, they have inherent limitations associated with thermoplastic polymer materials such as dimensional instability, low strength, and poor wear resistance. To solve these problems, we developed a new type of clear orthodontic retainer that incorporates multi-layer hybrid materials. It consists of three layers; an outer polyethylenterephthalate glycol modified (PETG) hard-type polymer, a middle thermoplastic polyurethane (TPU) soft-type polymer, and an inner reinforced resin core. The resin core improves wear resistance and mechanical strength, which prevent unwanted distortion of the bucco-palatal wall of the retainer. The TPU layer absorbs impact and the PETG layer has good formability, optical qualities, fatigue resistance, and dimensional stability, which contributes to increased support from the mandibular dentition, and helps maintain the archform. This new type of vacuum-formed retainer showed improved mechanical strength and rate of water absorption.

Physical properties and color stability of injection-molded thermoplastic denture base resins

  • Song, So-Yeon;Kim, Kyoung-Soo;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.32-40
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS. In this study, six commercially available products (VA; Valplast, LC; Lucitone, ST; Smiltone, ES; Estheshot-Bright, AC; Acrytone, WE; Weldenz) were selected from four types of thermoplastic denture base materials (Polyamide, Polyester, Acrylic resin and Polypropylene). The flexural properties and shore D hardness have been investigated and water sorption and solubility, and color stability have evaluated. RESULTS. For the flexural modulus value, ES showed the highest value and WE showed significantly lower value than all other groups (P<.05). Most of experimental groups showed weak color stability beyond the clinically acceptable range. CONCLUSION. Within the limits of this study, thermoplastic denture base resin did not show sufficient modulus to function as a denture base. In addition, all resins showed discoloration with clinical significance, and especially polyamides showed the lowest color stability.

다양한 레진 의치상의 적합도와 기계적 특성 (Adaptation accuracy and mechanical properties of various denture base resins: a review)

  • 이정환;이청재;이해형
    • 대한치과의사협회지
    • /
    • 제57권12호
    • /
    • pp.747-756
    • /
    • 2019
  • This paper reviews the adaptation accuracy and mechanical properties of currently used denture processing systems with base resin materials and introduces the latest research on the development of antimicrobial denture base resins. Poly(methyl methacrylate) has been successfully used as a dental denture base resin material by the compress-molding method and heat polymerization for a long time, but recently, new processing techniques, injection molding-methods or fluid-resin technique are also used for fabricating denture base. However, studies indicated that there was no difference between the injectionmolding and the conventional compression-molding method in terms of adaption accuracy of denture base. The fluid-resin fabrication and one injection-molding systems exhibited better adaptation accuracy than the other processing methods. Resin denture bases in the oral cavity may undergo midline fractures due to flexural fatigue from repeated masticatory loading. For those patients, impact resistant denture base resins are recommended to prevent denture fracture during service. Thermoplastic denture base resins can be helpful for patients suffering from allergic reaction to resin monomers with a soft-fit, however, thermoplastic resins with low stiffness can irritate gum tissues and accelerate abnormal alveolar ridge resorption. Moreover, due to low chemical durability in oral cavity, those should be used for a limited period of time.

  • PDF

고무 치공구와 필름 함침공정을 이용한 열가소성 장섬유 복합재료 성형공정 연구 (Thermoplastic Film Infusion Process for Long Fiber Reinforced Composites Using Rubber Expandable Tools)

  • 김동욱;안영선;이영관;김성우;남재도
    • 폴리머
    • /
    • 제25권1호
    • /
    • pp.122-132
    • /
    • 2001
  • 본 연구에서는 온도의 상승에 의하여 팽창하는 열팽창 기능을 가지고 있으면서 부피의 감소에 의하여 발생하는 압력의 손실을 상쇄시킬 수 있는 고무 치공구를 열가소성 고분자의 필름 함침공정에 적용하였다. 일반적인 압축성형공정에서는 온도의 상승에 의하여 수지가 용융되고 이에 수지가 함침됨에 따라 압력이 감소하지만, 고무 치공구를 사용한 경우에는 수지의 함침을 보상한 고무 치공구가 팽창하여 감소된 압력을 보상하기 때문에 급격한 압력의 강하를 억제할 수 있었다. 이렇게 수지의 함침에 따른 고무 치공구의 부피 팽창 그리고 이에 따른 수지 함침속도의 변화를 고려하여 고무 치공구를 이용한 필름 함침공정 모델을 제안하였다. 또한 고무 치공구를 사용하지 않는 일반적인 압축공정에 있어서 수지의 함침에 따른 섬유층 탄성력의 변화를 실험적으로 측정하여 단계적인 압축공정에 있어서 수지의 함침속도를 예측할 수 있는 모델을 제안하였다.

  • PDF

LFT-D 시스템을 이용한 탄소 장섬유 열가소성 복합재의 제조 및 인장특성 분석 (Fabrication and Characterization of Carbon Long-Fiber Thermoplastic Composites using the LFT-D System)

  • 신유정;정한규;박시우;박동욱;박열;정진우
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.25-30
    • /
    • 2017
  • Carbon-fiber-reinforced plastic (CFRP) composite materials have been widely used in various industrial fields because the design variables can be adjusted according to the application of the required structure. Thermosetting and thermoplastic resins are used as the base materials of CFRP composites for the lightweight construction of automotive components. Thermoplastics have several advantages such as no curing and recyclability compared to thermosetting resin. In this study, CFRP composites were made using the Long-Fiber Thermoplastic-Direct (LFT-D) process. The LFT-D process includes an in-line production system that directly impregnates a thermoplastic resin, extrudes the composite material, and molds it. This process increases the strength and decreases the molding time. The tensile strength characteristics on the mechanical properties of CFRP were analyzed according to the parameters of LFT-D based on thermoplastics. To analyze the properties of CFRP, the specimens were prepared based on the tensile test standard ASTM 3039 of composite materials.