Browse > Article

A STUDY ON THE BOND STRENGTH OF RELINE RESIN TO PRESSURE INJECTION TYPE THERMOPLASTIC DENTURE BASE RESIN  

Moon Tae-Sung (Department of Prosthodontics, College of Dentistry, Pusan National University)
Jeong Chang-Mo (Department of Prosthodontics, College of Dentistry, Pusan National University)
Jeon Young-Chan (Department of Prosthodontics, College of Dentistry, Pusan National University)
Lim Jang-Seop (Department of Prosthodontics, College of Dentistry, Pusan National University)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.40, no.1, 2002 , pp. 42-52 More about this Journal
Abstract
The purpose of this study was to evaluate the bond strength of reline resin to pressure injection type thermoplastic denture base resin. The denture base resins used in this study were $Hi-polycarbonate^{(R)}$(High Dental Co., Japan), Acetal $dental^{(R)}$(Pressingdental s.r.1., Repubblica di San Marine) of thermoplastic resin and Acron $MC^{(R)}$(GC Dental Industrial Co., Japan) of heat cured resin. The reline resins used were Lucitone $199^{(R)}$(Dentsply international Inc., USA), Tokuso $rebase^{(R)}$(Tokuyama Corp., Japan), and $Lightdon-U^{(R)}$(Dreve-Dentamid-Gmbh, Germany). The reline resins are representative of heat-cured, self-cured, and light-cured resin respectively Bond strength was examined by use of a three-point transverse flexural strength test. The results were as follows 1. The bond strength of Lucitone 199 to Acron MC was the highest. 2. The bond strengths of Lucitone 199 and Tokuso rebase to Hi-polycarbonate resulted in a value of approximately one half that of Lucitone 199 to Acron MC and there were no significant differences between these and the bond strength of Tokuso rebase to Acron MC(p<0.05) 3. The bond strengths of reline resins to Acetal dental were lower than those of reline resins to Hi-polycarbonate. 4. For all base resins Lightdon-U showed lower bond strength than the other reline resins.
Keywords
Thermoplastic resin; Polycarbonate; Polyacetal resin; Denture reline;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Anderson GC, Schulte JK, Arnold TG. Dimensional stability of injection and conventional processing of. denture base acrylic resin. J Prosthet Dent 1988:60:394-8
2 Clancy JM, Boyer DB. Comparative bond strengths of light-cured, heat-cured, and autopolymerizing denture resins to denture teeth. J Prosthet Dent 1989:61:457-62
3 Arena CA, Evans DB, Hilton TJ. A comparison of bond strengths among chairside hard reline materials. J Prosthet Dent 1993:70:126-31
4 정재헌. 총의치학. 청해사; 1995. p491-9
5 Garfunkel E. Evaluation of dimensional changes in complete dentures processed by injection-pressing and the pack-press technique. J Prosthet Dent 1983:50:757-61
6 Kimura H. A study on the dental injection molding system with cartridge (part 1)-polycarbonate denture base-. J. Osaka Univ. Dent. Sch. 1980;20:51-61
7 Fitton JS., Davies EH, Jowlett JA, Pearson GJ. The physical properties of a polyacetal denture resin. C Mater 1994;17:125-9   DOI   ScienceOn
8 Ortman HR, Ortman LF. Denture refitting with today's concepts and materials. Dent Clin North Am 1975:19: 269-90
9 김경남, 김교환, 김형일 등. 치과재료학. 군자출판사: 1995. p 141-89
10 Strohaver RA. Comparison of changes in vertical dimension between compression and injection molded complete dentures. J Prosthet Dent 1989;62:716-8   DOI   ScienceOn
11 Cucci AL, Vergani CE, Giampaolo ET, Maria C. da Silveira Ferreira Afonso. Water sorption. solubility, and bond strength of two autopolymerizing acrylic resins and one heat-polymerizing acrylic resin. J Prosthet Dent 1998:80:434-8
12 Winkler S. Denture base resins. Dent Clin North Am 1984:28:287-97
13 De Clerck JP. Microwave polymerization of acrylic resins used in dental prostheses. J Prosthet Dent 1987:57:650-8
14 김상길 공저. 재료과학과 공학. 희중당;1987. p416-8
15 Wifelet FA, Duncanson MG, Stratton RJ. Comparison of bond strengths of polymethyl methacrylate and alpha cyanoacrylate. J Prosthet Dent 1982:47:603-5
16 Ogle RE, Sorensen SE, Lewis EA. Anew visible light-cured resin system applied to removable prosthodontics. J Prosthet Dent 1986:56:497-506
17 Ruyter IE. Svendsen SA. Flexural properties of denture base polymers. J Prosthet Dent 1980:43:95-104
18 Beyli MS, von Fraunhofer JA. Repair of fractured acrylic resin. J Prosthet Dent 1980;44:497-503   DOI   PUBMED
19 Razavi R, KhanZ, von Fraunhofer JA. The bond strength of a visible light-cured reline resin to acrylic resin denture base material. J Prosthet Dent 1990:63:485-7
20 Craig RG : Restorative dental materials. 8th Ed., C.V Mosby Co.: 1989. p509-59
21 Smith DC. Recent developments and prospects in dental polymers. J Prosthet Dent 1962;12:1066-78   DOI
22 Buyukyilmaz S. Ruyter IE. The effects of polymerization temperature on the acrylic resin denture base-tooth bond. lnt J Prosthodont 1997;10: 49-54
23 Arima T, Nikawa H, Hamada T, Harsini. Composition and effect of denture base resin surface primers for reline acrylic resins. J Prosthet Dent 1996:75:457-62
24 Dar-oder NS, Harrison A, Abu-hammad O. An evaluation of self-cured and visible lightcured denture base materials when used as a denture base repair material. J Oral Rehabili 1997: 24: 755-60
25 Zarb GA, Bolender CL, Carsson GE. Boucher's prosthodontic treatment for edentulous patients. 11Ed C.V Mosby Co.: 1997. p390-9
26 Takayama T, Setcos JC. Resin denture base : Review of accuracy and methods of polymerization. lnt J Prosthodont 1989: 2:555-62
27 Nogueira SS, Ogle RE, Davis EL. Comparison of accuracy between compression-and injection-molded complete dentures. J Prosthet Dent 1999:82:291-300
28 Turner JW, Radford DR, Sherriff M. Flecural properties and surface finishing of acetal resin denture clasps. J Prosth 1999;8: 188-95   DOI   ScienceOn
29 Andreopoulos AG, Polyzois GL, Demetriou PP. Reparis with visible light-curing denture base materials. Quintessence lnt 1991 ;22:703-706
30 Khan Z, von Fraunhofer ZA, Razavi R. The staining characteristics, transverse strength, and microhardness of a visible light-cured denture base material. J Prosthet Dent 1987:57:384-6
31 O' Brien WE. Dental materials: properties and selection. Quintessence Publishing Co.: 1989. p157-76
32 Phillips RW : Skinner science of dental materials. 8th Ed., W.B Saunders Co.: 1982. p161-216
33 Cucci AL, Rached RN, Giampaolo ET, Vergani CE. Tensile bond strengths of hard chairside reline resins as influenced by water storage. J Oral Rehabil 1999;26:631-4   DOI
34 Demetriou PP, Polyzois GL, Andreopoulos AG. Reinforced cyanoacrylates as repair materials. J Mater Sci Letter 1988;7:13   DOI
35 이종률, 김경남 역. 精選 치과재료학. 한국퀸테센스출판사; 1995. p100-40
36 Huggett R, Zissis A, Harrison A, Amanda Dennis. Dimensional accuracy and stability of acrylic resin denture bases. J Prosthet Dent 1992:68: 634-40
37 Geerts GA, Jooste CH. A comparison of the bond strengths of microwave- and waterbath-cured denture material. J Prosthet Dent 1990:70:406-9