• 제목/요약/키워드: Thermal-Comfort

검색결과 700건 처리시간 0.027초

전통온돌난방의 실내 온열환경 쾌적감 평가에 관한 연구 (A Study on the Indoor Thermal Comfort of the House with Ondol Heating System of Korean Traditional Housing)

  • 강상우;전지현;국찬
    • 한국주거학회논문집
    • /
    • 제18권4호
    • /
    • pp.1-7
    • /
    • 2007
  • The principle of Korean Traditional Housing was to be harmonized with the nature with shapes according to regional climate and materials easily available from the region. These environmentally friendly characteristics protected indoor environment from climate changes. The characteristics of Korean traditional housing to control indoor environment would be very useful for contemporary housing in that current issues, improving housing amenity and wellbeing, had basic goals same with what Korean Traditional Housing had. Though it could be found characteristics of indoor thermal environment heated by Ondol Heating System, analyses of evaluation made by occupants of the rooms were insufficient because most of the studies had been focused on the measurement of indoor thermal factors. Thus, with an evaluation of occupants for the indoor thermal comfort and an estimation of discomfort derived from the result of vertical temperature distribution, it was studied whether the agreeable indoor range of rooms, of which was Jeonju Hanok Living Experience Center, heated by Ondol Heating System corresponded to the agreeable indoor range presented in references.

기후변화 대응 건축물 기화냉각시스템 적용에 따른 외부 열환경 변화 연구 (Changes in the External Heat Environment of Building Evaporative Cooling Systems in Response to Climate Change)

  • 윤용한;권기욱
    • 한국환경과학회지
    • /
    • 제27권12호
    • /
    • pp.1261-1269
    • /
    • 2018
  • The purpose of this study was to investigate changes in the external thermal environment, following the application of evaporative cooling systems in buildings, in response to climate change. In order to verify changes in the external thermal environment, a T-test was performed on the microclimate, Thermal Comfort Index (TCI), and building surface temperature. Differences in microclimate, following the application of the evaporative cooling system in the building, were significant in terms of temperature and relative humidity. In particular, temperature decreased by more than 7% when the evaporative cooling system was applied. According to the results of the Thermal Comfort Index analysis, the Wet-Bulb Globe Temperature (WBGT) was below the limit of outdoor activities, indicating that outdoor activities were possible. The Universal Thermal Climate Index (UTCI) values were within the very strong heat stress range when the evaporative cooling system was not applied, When the system was applied, the UTCI values were within the strong heat stress range, indicating that they were lowered by one level. The building surface temperature decreased by ~10% or more when the evaporative cooling system was applied, compared to when it was not applied. Finally, the outside surface temperature of the building decreased by ~12% or more when the system was applied, compared to when it was not applied. We conclude that the energy saving effect of the building was significant.

UAV와 ENVI-met을 활용한 공간 유형별 열환경 특성 분석 (Analysis of Thermal Environment Characteristics by Spatial Type using UAV and ENVI-met)

  • 김성현;박경훈;이수아;송봉근
    • 한국지리정보학회지
    • /
    • 제25권1호
    • /
    • pp.28-43
    • /
    • 2022
  • 본 연구는 창원시 도시지역 내 공원을 대상으로 UAV 영상 기반 물리적 공간 유형을 분류하고, ENVI-met 열 쾌적성 결과와의 비교를 통해 물리적 공간 유형에 따른 열 쾌적성 특성을 분석하였다. 물리적 공간 유형은 UAV 기반 NDVI, SVF 특성에 따라 4개 유형으로 분류하였다. ENVI-met 열 쾌적성 결과는 수목 밀집지역의 TMRT가 그 외 지역보다 최대 30℃ 이상의 차이를 보였으며, 오후 시간대 중에서는 수목 밀집지역과 다른 지역의 TMRT 차이가 16시에 19.6℃로 가장 큰 것으로 나타났다. UAV 기반 물리적 공간 유형과 시간대별 열 쾌적성 특성 분석결과 NDVI가 높고, SVF가 높은 공간 유형에 대해 UAV 활용 시 시간대별 열 쾌적성 변화 패턴과 유사한 경향을 보이는 것을 확인하였으나, 수목 및 인공 구조물 등이 밀집된 지역에 대해서는 상대적으로 UAV 기반 물리적 환경 유형과 상관관계가 낮은 것으로 나타났다. 결론적으로 개활지 및 식생으로 이루어진 공간 유형에 대해 UAV 영상 기반 열 쾌적성 분포 파악 가능성을 확인하였으며, 수목 인접지역이 개활지보다 열적으로 쾌적한 것으로 도출되었다. 따라서, 도시계획 단계에서 개활 공간은 잔디 및 수목 등 자연피복재질을 고려하여 조성할 필요가 있으며, 인공피복재질 활용 시 수목, 건물과의 인접성 등을 고려한 공간계획이 이루어져야 할 것으로 판단된다. 향후 지상LiDAR 및 현장 측정 기반 UAV 영상 보정을 통해 신속·정확한 도시기후 현상 규명 및 열 쾌적성을 고려한 도시계획 수립이 가능할 것으로 판단된다.

안면 피부온도를 활용한 PMV 지표 기반 쾌적환경 조성의 타당성 연구 (The Validation Study of Shaping Comfortable Environments Based on the PMV Index Using Facial Skin Temperature)

  • 김보성;민윤기;신에스더;김진호
    • 감성과학
    • /
    • 제16권3호
    • /
    • pp.311-318
    • /
    • 2013
  • 본 연구는 인간의 생리적 지표 중 하나인 안면 피부온도를 활용하여 PMV 지표 값에 기반하여 조성된 쾌적/불쾌 실내 환경을 적절하게 구분할 수 있는지 그 타당성을 살펴보고자 하였다. 이를 위해 쾌적 실내 환경에 해당되는 PMV 지표 값을 기준으로 물리적 환경을 쾌적 실내 환경과 불쾌한 실내 환경으로 각각 구분하고, 구분된 환경내에서 재실자의 안면 피부온도를 측정하였다. 그 결과, PMV 지표 값으로 구분된 쾌적 실내 환경과 불쾌한 실내 환경에서의 재실자의 안면 피부온도가 서로 차이를 보이는 것으로 나타났다. 이는 안면 피부온도가 PMV 지표에 기반한 쾌적한 실내 환경 조성에 있어 활용될 수 있음을 시사한다. 그러나 쾌적한 실내 환경에 비해 불쾌한 실내 환경에서 안면 피부온도가 낮게 나타나는 결과를 통해 오히려 PMV 지표 값에 기반을 두고 조성되는 쾌적/불쾌환경이 타당하지 않을 수 있음도 시사한다.

  • PDF

청바지의 소재별 쾌적감에 관한 연구 (Comport Sensation of Blue Jeans depending on Fiber Contents)

  • 홍문경;이미식;권계화;전정애
    • 한국의류학회지
    • /
    • 제25권2호
    • /
    • pp.237-248
    • /
    • 2001
  • The purpose of this study was to compare the comfort sensation depending on four different kinds of denim blue jeans: cotton, cotton/tencel, tencel, cotton/pp. The objective and subjective experiments were conducted to measure the comfort of blue jeans. To investigate the objective comfort, physical properties related to thermal insulation, moisture properties and hand were measured. For subjective comfort measurement, 5 healthy female college students were taken as subjects. The outcomes of the experiments are as follows: The higher the air permeability and bulk density of the denim, the lower the thermal insulation, the thicker the denim, the higher the thermal insulation. Tencel blending denim showed the higher bulk density, the lower air contents, and consequently the lower thermal insulation than the other denims. Tencel showed the highest moisture regain, and cotton/tencel blend showed the highest water vapor permeability. Tencel denim had relatively better flexibility, shape stability and elastic recovery than the other denims. The total hand values of the denims by KES-FB system were not significantly different. Cotton and cotton/pp denims raised the subjects body temperature after excercise more than tencel or cotton/tencel denims. Average skin temperature was found to have a correlation with micro climate temperature and micro climate humidity. The correlation coefficients were 0.749 and 0.767, respectively. However, average skin temperatures were not significantly different among the materials. Pulse rate was found to be the highest when wearing cotton/pp and the lowest in case of cotton/tencel denim. The energy was consumed in order of cotton>cotton/pp>tencel>cotton/tencel. There was no significant difference in preference before excercise, but, after the excercise, the order of preference changed as the following; cotton/tencel>tencel>cotton/pp>cotton.

  • PDF

신한옥의 쾌적성능 평가: 전남 화순 잠정햇살마을 한옥단지를 대상으로 (Evaluation of Comfort Performance for Modernized Hanok: Targeting Hanok Residence at the Jamjeong-Haetsal Village in Hwasun, Jeonnam Province)

  • 최승주;이미향;김재향;한승훈
    • 토지주택연구
    • /
    • 제12권2호
    • /
    • pp.99-108
    • /
    • 2021
  • 이 연구의 목적은 한옥 거주환경의 쾌적성능에 대한 정량적 자료를 제시하고 개선 요인을 도출하는 데 있다. 먼저 정책적 성공사례로서 현대(신(新))한옥의 하나인 전남 화순군 잠정햇살마을 한옥단지를 대상으로 건구온도, 복사온도, 상대습도, 풍속 등 열쾌적성 평가의 영향 요소를 측정했다. 이어 도출 데이터를 적용하여 PMV(Predicted Mean Vote)를 산출하는 열환경 시험을 수행했으며, 사용자 대사율과 의복량을 변수로 설정하여 L.C.PMV(Life-Cycle PMV)와 N.PMV(Normal PMV)의 두 가지 유형으로 구분하여 평가를 진행했다. 그 결과, 여름 및 겨울철 시점을 전후하여 한옥 공간의 PMV 증감 동향이 뚜렷했으며, 특히 대서 및 대한 시점의 PMV는 쾌적구간을 완전히 벗어난다는 시험 결과를 확인했다. 아울러 겨울철 PMV의 변화 속도가 여름철보다 더 빠른 것으로 나타났다. 이러한 결과를 통해 신한옥의 쾌적성능 증진을 위해 단열성 개선이 우선 요인임이 도출되었으며, 설계 및 시공 단계에서 연계 검토가 요구된다.

가온가습호흡회로 적용이 전신마취 환자의 체온, 전율, 온도 편안감에 미치는 효과 (Effects of the Heated-Humidified Breathing Circuit Applied on the Body Temperature, Shivering, and Thermal Comfort of General Anesthesia Patients)

  • 손원미;박정숙
    • 동서간호학연구지
    • /
    • 제26권2호
    • /
    • pp.149-156
    • /
    • 2020
  • Purpose: The purpose of this study was to identify the effects of the heated-humidified breathing circuit applied on the body temperature, shivering, and thermal comfort of general anesthesia patients. Methods: The participants were patients who received general anesthesia at University Hospital K located in City B, with 25 patients in the experimental group and 25 patients in the control group. The period of this study was from Mar 19 to Apr 26, 2019. The experimental equipment included a heated-humidified breathing circuit, which connects the intubation tube with the anesthesia machine for mechanical ventilation after airway intubation in general anesthesia patients. Results: The body temperature, shivering, and thermal comfort after surgery were significantly different between the two groups (p<.001). However, the body temperature during surgery was slightly different between the experimental group and the control group. Conclusion: A heated-humidified breathing circuit may be actively used in a warming method to prevent the hypothermia of general anesthesia patients.

590인승 Ro-Pax형(型) 연안여객선의 선실 내 봄철 온열환경 측정평가 (A Measurement and Evaluation of Indoor Thermal Conditions in Spring of a Coastal Passenger Ship - 590-Passenger Ro-Pax Type)

  • 황광일;신동걸;김은수;도요한;최윤석;최정열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1170-1177
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions in the spring of a korean coastal passenger ship which is 590-passenger Ro-Pax type built at 1997. Especially this study has focussed on the relations between the diffuser open ratio, which can be controlled by 12 steps, and the comfort. Followings are the results of this study. (1) The supply air volume to cabins are maximum 4.3 and 2 times more than design quantity when the diffusers in cabins are open 100% and 50%, respectively. (2) Regardless of diffuser open ratio, the supply air maintains constantly high temperature and below 10% of relative humidity through the experimental days. (3) All the cabins are not satisfied with the ASHRAE comfort criterion at the condition of 100% and 50% of diffuser open ratio, because of high temperature and low relative humidity. (4) At a low diffuser open ratio, number of cabins which satisfy the ASHRAE comfort criterion are increased. (5) Humidifying and dehumidifying, and hvac control system of each cabin must be reviewed and studied at the view of passengers to service more comfort environments.

쾌적제어를 위한 수면 초기 실내온도 변동이 인체 생리에 미치는 영향 (The Effect of Indoor Temperature Change on Human Physiology for Comfort Control during Sleep Early Stage)

  • 신효준;김동규;정석권;금종수;김형철
    • 동력기계공학회지
    • /
    • 제11권3호
    • /
    • pp.29-34
    • /
    • 2007
  • Existent researches about indoor thermal environment have been focused on to seek human's comfort in daytime. Also researches about thermal comfort during the sleeping time that is important for resting and recharging to modern people have been seldom existed. At present, as global warming phenomenon is being continued, most people are going through inconvenience by sultriness during the sleeping hours in sweltering summer night. Therefore we need another control method of an air conditioner to keep human's thermal comfort. Ambient temperature is a common factor of the environment, but analysis of its effect on human body physiology is still unknown. The effect of ambient temperature on human sleep has been increasingly studied in the last decade. This research investigated about optimal indoor temperature to maintain proper skin temperature and comfortable sleep when indoor air is cooled by an air conditioner in sweltering summer night.

  • PDF

방열핀이 난방용 패널의 열적거동 및 성능에 미치는 영향 (The Effects of Heat Diffusion Fin on the Thermal Behavior and Performance of Radiant Heatomg Panel)

  • 이태원
    • 대한기계학회논문집
    • /
    • 제18권9호
    • /
    • pp.2486-2493
    • /
    • 1994
  • Transient heat transfer characteristics in th radiant heating panel with heat diffusion fin were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with advance of time, were obtained for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various design conditions, such as pipe pitch, area ratio and thermal conductivity of optimal design of the new heating panels with heat diffusion fin. It was concluded that the efficient area ratio of heat diffusion fin is about 0.5, and the greater the thermal conductivity of fin is, the better the performance of panel is.