• 제목/요약/키워드: Thermal-Comfort

검색결과 700건 처리시간 0.022초

시뮬레이션을 통한 바닥복사냉방 시스템의 공급유량 및 냉수온도 제어에 관한 연구 (A Study on the Control of Water Flow and Water Temperature in the Radiant Cooling System through Simulations)

  • 김용이;윤혜림;여명석
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.532-540
    • /
    • 2001
  • The objectives of this study are to analyze the control variables according to condensation occurrence, to find the range in floor surface temperature and frequency of condensation, and to evaluate the control methods through simulations when the radiant heating system is used for cooling. Through the simulation analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The results show that the lowest floor surface temperature is around $23^{\circ}C$, the surface condensation can be prevented by controlling indoor humidity within 20g/kg(DA0, and that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

야외 운동복에서의 수분전달 (The Water Vapour Transfer on Outdoor Activities Clothing)

  • Oh, Ae-Gyeong
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.115-118
    • /
    • 2001
  • The water vapour permeability of clothing materials is a critical property for clothing systems that must maintain thermal equilibrium for the wearer. The evaporation of perspiration provides the means of cooling the human body. The perspiration should evaporate from the surface of the skin and pass as water vapour through the clothing, which must be permeable for comfort. The primary objectives in this study of the transfer through fabrics of water vapour are to measure this property in a quantitative manner appropriate to clothing systems and to provide an increased understanding of various types of fabric in water vapour transfer. (omitted)

  • PDF

유리 색에 따른 아트리움 실내공간의 채광분위기 평가 (A Study on The Evaluation of Interior Atmosphere in Atrium with Glass Colour)

  • 정유근;김찬수;김정태
    • KIEAE Journal
    • /
    • 제3권3호
    • /
    • pp.51-58
    • /
    • 2003
  • This Study aims to evaluate the interior atmospheres of atrium by glass colours. For the purpose, the 1/50 scale model of one-sided atrium was made and images of interior atmospheres were pictured under clear sky conditions. And then, questionnaire surveys were conducted on K university students in department architecture engineering. The survey results were analyzed by SPSS program. Frequency and correlation analysis were performed. As results, clear glass is chosen as the most preferred glass colour in any seasons. And, green and blue glasses are preferred in the order. And then, it is revealed that the main variables affecting satisfaction of interior atmospheres are a little changed by thermal senses of seasons. These variables are "bright", "neat", "warm", "comfort", "stable", "active", "static", "elegant" and "cool" through correlation analysis.

외기 전용 공조기의 동특성 시뮬레이션 (Dynamic Simulation of a Dedicated Outdoor Air-conditioning System)

  • 김정민;김영일;정광섭;박승태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.322-327
    • /
    • 2007
  • Dedicated outdoor air-conditioning(DOA) system that utilizes pre-cooling and desiccant dehumidification can be superior to conventional cooling and reheating system with respect to energy consumption and indoor thermal comfort. In this work, simulation has been conducted to study various factors that affect the performance of DOA. Dynamic simulation shows the transient variation of temperature and humidity as the on/off control logic is imposed. Exit humidity of process air and flow rate are varied to study the effect on exit temperature of process air, dehumidification quantity, required regeneration temperature and exit humidity of regeneration air. For an outdoor air condition of $28.5^{\circ}C$ temperature, 16 g/kg humidity ratio and 2000 cmh flow rate, the dehumidification efficiency is increased by 4.6% as the flow rate is doubled.

  • PDF

중앙냉방시스템의 준최적 설정점제어기법 구현에 관한 연구 (An Implementation for Near-Optimal Set Point Control for Central Cooling Systems)

  • 백승재;송재엽;안병천;주영덕;김진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.46-51
    • /
    • 2007
  • The near-optimal control algorithm for central cooling system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air temperature and chilled water temperature. This study has been done by using LapVIEW program with PID control in order to analyze the central cooling system energy saving.

  • PDF

중앙냉방시스템의 실시간 준최적제어 적용에 따른 실험적 연구 (Real Time Near Optimal Control Application Strategy of Central Cooling System)

  • 안병천;송재엽;주영덕;김진
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.470-477
    • /
    • 2008
  • The near-optimal control algorithm for central cooling system has been developed for minimizing energy consumption while maintaining the comfort of indoor thermal environment in terms of the environmental variables such as time varying indoor cooling load and outdoor temperatures. The optimal set-points of control parameters with near-optimal control are supply air and chilled water temperatures. The near optimal control algorithm has been implemented by using LabVIEW program in order to analyze energy performance for central cooling control system.

철도 전동차내의 실내공기질 평가 - 온도 및 습도를 중심으로 - (Evaluation of Indoor Air Quality in the Railroad Electric Rolling Stock - Focused on Temperature and Humidity -)

  • 박덕신;배상호;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 춘계학술대회 논문집
    • /
    • pp.610-615
    • /
    • 2003
  • Electric rolling stock is one of major public transportation because of an increase in population and heavy traffic problems. The passengers under the influenced of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system on passenger cars should be designed for the health and comfort of the passengers. One of the main aim is to create an acceptable thermal environment without draught problems. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in passenger cars is turbulent. Lateral temperature and humidity gradients in the electric rolling stock have been studied. And, the difference in the mean temperature and relative humidity measured at 0.7, 0.9, 1.2, 1.7 m above from the floor.

  • PDF

전동차 공조기 덕트 내의 유동특성에 관한 수치해석적 연구 (Numerical study on the flow characteristics in Air-conditioner duct of EMU)

  • 김승택;김성종;박근수;박형순
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.345-350
    • /
    • 2003
  • The inside of EMU is supplied with the cooling air from air-conditioner and the fresh air from exterior through the air-conditioner duct which is one of the air conditioning system. The shape of air-conditioner duct is a major factor in determining the air-conditioning efficiency, thermal comfort and energy efficiency. Therefore, this study is to understand the flow characteristics in the air-conditioner duct by three dimensional numerical simulation. The air-conditioner duct was calculated for the design volume flow rate, $2,726\;m^3/h/unit$. From the result of calculation and measurement, the velocity at diffuser outlet presented good agreement in general. [n this present study, the calculation was also performed for three volume flow rate(1,800, 2,200, 3,000 $m^3/h/unit$) and total pressure characteristic curve with volume flow rate was presented.

  • PDF

온돌을 이용한 바닥복사냉방의 제어성능에 관한 실험적 연구 (An Experimental Study on Control Performance of Radiant Floor Cooling Using Ondol)

  • 김용이;임재한;한여명;김광우
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1165-1173
    • /
    • 2001
  • The objectives of this study are to analyze the application of radiant floor cooling and to evaluate the control methods through experiments when the radiant heating system is used for cooling. Through the experiment analysis the control methods such as on/off control, variable flow control and outdoor reset with indoor temperature feedback control are evaluated and compared. The cooling curve (reset ratio) is found for radiant cooling, which shows tole relation between outside air temperature and supply water temperature. Comparison of cooling methods shows that outdoor reset with indoor temperature feedback control is more appropriate than on/off control and variable flow control with regard to prevention of the condensation and thermal comfort.

  • PDF

개별공조에 의한 CR에서의 Heat Gain과 재실자 온열성 연구 (Occupant's Thermal Comfort and Heat Gains in CR by PEM)

  • 김원태
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 추계학술대회 논문집
    • /
    • pp.13-18
    • /
    • 1999
  • 기존의 공조방식 및 본 연구에서 제안한 개별환경제어시스템(PEM)으로부터 열유체 유동 헤석용 PHOENICS 프로그램을 이용하여 3차원 시뮬레이션을 수행하여 재실자가 거주하고 있는 CR(컴퓨터실)에서의 Heat Gain과 재실자 온열성 특성을 감성공학적 측면에서 분석하였다. 본 연구로부터 바닥으로부터 공기를 유입하여 천정으로 유출하는 바닥취출공조방식이 실내 환경 개선에 유리하고 diffuser만을 통하여 공기가 유입되어 천정과 바닥으로 공기가 유출되는 PEM 방식은 열적 냉각 성능은 좋으나 PC와 재실자 주변에 강력한 재순환 유동이 발생되어 실내 환경의 쾌적성 측면에서는 불리하나 PEM과 TAM방식의 결합이 감성공학적 온열특성 분포로부터 CR실의 재실자 주변 온도 분포에 최적임을 알 수 있다.

  • PDF