• 제목/요약/키워드: Thermal-Comfort

검색결과 700건 처리시간 0.024초

신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발 (Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks)

  • 김형중;두석배;신중린;박종배
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권10호
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.

평균피부온도 분석을 통한 수면시 쾌적 실내 온도조건에 관한 연구 (Study on Comfortable Room Temperature using Mean Skin Temperature analysis in Sleeping)

  • 김동규;정용현
    • 수산해양교육연구
    • /
    • 제19권2호
    • /
    • pp.161-167
    • /
    • 2007
  • It is necessary to control the room temperature for comfortable and deep sleep during a tropical night. We need to investigate thermal transport and parameter between human and environment for comfortable sleep. Therefore this study is performed to evaluate the comfortable room temperature based on the change of skin temperature under variations in thermal conditions and several reports. Five female subjects of 20~22 years with similar sleeping pattern were participated for the experiment. The subjects arrived in chamber at 9 pm and adapted to thermal circumstances during 2 hours. The sensors was sticked in body for skin temperatures. If subjects fall asleep in chamber, lights off and then sleep during 8 hours.As results, indoor temperature range for comfort sleep was $23.9{\sim}28.4^{\circ}C$ based on comfort mean skin temperature. But considering transition of time, minimum indoor temperature was $21.6^{\circ}C$, $22.9^{\circ}C$, $24.1^{\circ}C$, $23.9^{\circ}C$ and maximum indoor temperature was $28.2^{\circ}C$, $30.1^{\circ}C$.

이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구 (A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick)

  • 김용기;이태원
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.183-189
    • /
    • 2012
  • Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.

The study of the calculation of energy consumption load for heating and cooling in building using the Laplace Transform solution

  • Han, Kyu-Il
    • 수산해양기술연구
    • /
    • 제50권3호
    • /
    • pp.292-300
    • /
    • 2014
  • The Laplace Transform solution is used as a mathematical model to analyse the thermal performance of the building constructed using different wall materials. The solution obtained from Laplace Transform is an analytical solution of an one dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures. The main purpose of the study is showing the detail of obtaining solution process of the Laplace Transform. This study is conducted using weather data from two different locations in Korea: Seoul, Busan for both winter and summer conditions. A comparison is made for the cases of an on-off controller and a proportional controller. The weather data are processed to yield hourly average monthly values. Energy consumption load is well calculated from the solution. The result shows that there is an effect of mass on the thermal performance of heavily constructed house in mild weather conditions such as Busan. Building using proportional control experience a higher comfort level in a comparison of building using on-off control.

실내수영장의 열, 기류 및 습도환경에 관한 연구 (A Study of Thermal, Air-flow and Humidity Conditions in an Indoor Swimming Pool)

  • 강석윤;이태구;문종선;이재헌
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.683-689
    • /
    • 2003
  • The thermal comfort of an indoor swimming pool is different from that of general indoor space because of the characteristics of large space and the wear conditions of swimmers. Dew condensation by humid air not only makes mold on the floor, wall and roof but also decreases the durability of buildings by penetrating into their structures. In this study, the characteristics of the flow field, the temperature field and the humidity distribution in an indoor swimming pool have been examined by the numerical method to estimate the level of thermal comfort and the generation rate of dew condensation. The results showed that the dew condensation regions were spread widely at the eastern parts of the swimming pool due to the insufficient air flow rate with low velocity and temperature. To prevent the generation of dew condensation in a region, a sufficient warm air flow rate should be supplied to make an air mixing. The values of PMV at horizontal plane of 1.5 m height have the range of -1.0∼1.2, which means the suitable level for swimmers.

여름철 내열성 증진을 위한 정량적 착의훈련의 효과 (제1보) -20대 여성의 적정착의 온도 설정: 의복내 온도를 중심으로- (A Study on Quantitative Wear Training for the Improvement of Heat Tolerance in Summer (Part I) -20's Females' Optimal Wearing: Focus on Inside Clothing Temperatures in Pre-summer-)

  • 이효현;최정화
    • 한국의류학회지
    • /
    • 제36권3호
    • /
    • pp.259-268
    • /
    • 2012
  • This study suggests quantitative guidelines for inside clothing temperatures to improve the heat tolerance of 20's females in summer. First, the inside clothing temperatures ($T_{cl}$) of each subject was measured in daily use. The subjects were asked to record subjective thermal sensations, clothing items worn, clothing weight, and activities during an experiment designed to determine the comfort zone of $T_{cl}$. In a thermally neutral state, the comfort zone of $T_{cl}$ was decided on a mean value $T_{cl}{\pm}1{\sigma}$. Second, the subjects were asked to wear clothing that would enable them to feel 'slightly warm but still comfortable'. The rest of the processes were the same as previous steps that were designed to understand the way and degree of clothing control. The comfort zone of $T_{cl}$ was decided in the same manner as the previous step. The two comfort zones were combined and named the combined comfort zone of the definitive comfort zone. The results were as follows: 1. Thermally comfortable $T_{cl}$, Hcl were $34.0{\pm}1.1^{\circ}C$, $40{\pm}9%%RH$ and the thermally comfortable ambient climate was $25.0{\pm}1.6^{\circ}C$, $53{\pm}7%$RH. 2. When subjects were asked to wear 'slightly warm but still comfortable', there were difference in thermally comfortable $T_{cl}$, clothing weight and clothing layer by subject. 3. In this study, the optimal $T_{cl}$ was decided on the mid-point of the definitive comfort zone of $T_{cl}$.

보건의료시설의 실내 예상 평균 온열감(PMV), 이산화탄소 농도, 소음도, 조도의 통합실내쾌적도(IEQh)를 통한 연간 실내 쾌적도 평가 (Evaluation of Annual Indoor Environment Quality in Hospitals using Various Comfort-related Factors)

  • 이보람;이대엽;반현경;이세원;김규상;이기영
    • 한국환경보건학회지
    • /
    • 제43권3호
    • /
    • pp.214-222
    • /
    • 2017
  • Objectives: A hospital is a complex building that serves many different purposes. The indoor environment in a hospital plays a major role in patient well-being and the work efficiency of the hospital staff. This study was conducted to evaluate overall comfort in two major hospitals over the course of one year. Methods: Various indoor environmental conditions were measured in two general hospitals for one year (April 2014 to April 2015). Monitoring alternated between the hospitals at one month per respective monitoring session. The indoor air temperature, relative humidity (RH), mean radiant temperature and air velocity were measured in order to calculate the predicted mean vote (PMV). Carbon dioxide concentration, noise level and illumination level were concurrently measured and applied to the overall IEQ acceptance model for the hospitals (IEQh). Results: The IEQh at the two general hospitals was different at five spaces within a building. The IEQh for summer and winter were significantly different. Real-time IEQh demonstrated that indoor comfort was affected by the hospital's operating hours due to operation of the HVAC system. The percentage of indoor comfort in the hospitals was higher using PMV than IEQh. Conclusion: IEQh in the hospitals was different at locations with different purposes. Indoor comfort assessment using IEQh was stricter than with PMV. Additional research is needed in order to optimize the IEQh model.

老人福祉施設의 冬.夏節期 室內 溫熱環境 測定 및 溫熱感 評價 (An Study on the Evaluation of Thermal Indoor Environment and Thermal Sensations during Winter and Summer in Elderly Welfare Facilities)

  • 곽호;류우동;황광일;홍원화
    • 한국주거학회논문집
    • /
    • 제14권1호
    • /
    • pp.19-27
    • /
    • 2003
  • This study aims to survey the living spaces of the welfare facilities for the aged to get the objective relationships between the physical thermal environment and the users' subjective responses. The surveys were made twice in winter and once in summer during 2001 and 2002. An ambient temperature, relative humidity, air velocity, globe temperature were measured as physical elements of thermal environment and the ASHRAE Psychophysical Voting Scale were used as an evaluation index for subjective responses. As the results, the aged respond thermally comfortable, in spite of the differences among important factors such as thermal sensations, humidity sensations and air velocity sensations. Also the physical thermal environmental elements and the subjective responses indices exceed thermal comfort range calculated by PMV(Predicted Mean Vote) and PPD(Predicted Percentage Dissatisfied). It shows that the insulation of walls of the facilities is not enough for heating and cooling seasons, and the indoor environmental control is necessary.

여름철 해변지역의 인간 열환경지수 및 열쾌적성 - 제주특별자치도 제주시 구좌읍 월정리 해변 - (Human Thermal Sensation and Comfort of Beach Areas in Summer - Woljeong-ri Beach, Gujwa-eup, Jeju-si, Jeju Special Self-Governing Province -)

  • 박수국;신지환;조상만;현철지;강훈
    • 한국조경학회지
    • /
    • 제44권4호
    • /
    • pp.100-108
    • /
    • 2016
  • 최근에 관광기후지수가 생리등가온도(PET)와 범용열기후지수(UTCI)와 같은 완전한 인간 에너지 균형 모델들을 포함함으로써 발전되어 오고 있다. 이 연구는 해변에서의 조경계획 및 설계를 위해, 2015년 봄과 여름에 대한민국 제주특별자치도 월정리해변에서 인간 열환경지수 및 열쾌적성을 조사하였다. 미기후 측정과 국제표준화기구 10551을 바탕으로 만들어진 설문조사를 동시에 실시하였으며, 성인 869명이 참가하였다. 그 결과, 생리적인 요소만 고려된 '열환경 지각'과 '열환경 선호도'가 선형 회귀 분석에서 생리등가온도와 92.8과 87.6%의 높은 결정계수를 나타내었다. 그러나, 생리적 요소와 심리적 요소 둘 다 고려된 '열환경 평가', '열환경 수용도'와 '열환경 부담도'에서는 60.0, 21.1, 46.4%로 낮은 결정계수를 보였다. 그렇지만, 생리등가온도와의 상관성 분석에서는 모두 0.01 레벨에서 유의성이 있는 것으로 나타났다. 인간 열환경 지수를 나타내는 '열환경 지각'에서 덥지도 춥지도 않는 '중간'의 생리등가온도의 범위는 $25{\sim}27^{\circ}C$로 나타났으나, 미국의 냉온난방협회 표준 55에서 추천한 20% 이하의 불만족성 범위는 없었다. 다만, '열환경 평가'와 '열환경 부담도'에서 $21{\sim}32^{\circ}C$$17{\sim}37^{\circ}C$의 생리등가온도 범위들이 그 추천범위에 속하는 것으로 나타났다. 그러므로, $21{\sim}32^{\circ}C$의 생리등가온도를 해변지역의 조경계획 및 디자인뿐만 아니라 관광 및 레크리에이션 계획을 위한 인간 열쾌적성 범위로 적용될 수 있을 것이다. 해변에서의 열 스트레스 레벨들은 한국의 내륙들보다 $2{\sim}5^{\circ}C$ 높게 나타났으며, 대만과 나이지리아와 같은 열대지역과 유사한 높은 결과들을 보였고, 서 중유럽과 이스라엘의 텔아비브보다 높은 것으로 나타났다.

도시주택의 여름철 온열환경에 관한 측정실험 연구 (A Study on the Summer Thermal Environment in Korean Urban Residences)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제27권1호
    • /
    • pp.71-83
    • /
    • 1989
  • This is a basic study designed to discover the most comfortable thermal environment for Korean residences. The purpose of the research is to observe and measure the summer thermal environment in Korean urban detached single family houses and apartments by utilising proposed evaluation standards and methods. The technique used involves the measurement of environmental elements, such as indoor temperature, relative humidity and radiant temperature both in detached single family houses and apartments. Also, in order to understand the resident's thermal comfort response. ASHRAE' thermal sensation 9th level, indoor temperature 5th level, and thermal discomfort 4th level in the psycho-physical voting scale (1972) was used. In conclusion, among Korean urban residences, detached single family houses provided a more stable thermal environment than apartments, as shown by physical psychological evaluations. The possible reason for such stability in detached single family houses may be the usage of reinforced concrete structures which maintain consistent temperatures.

  • PDF