DOI QR코드

DOI QR Code

A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick

이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구

  • Kim, Yong-Ki (Green Building Division, Korea Institute of Construction Technology) ;
  • Lee, Tae-Won (Green Building Division, Korea Institute of Construction Technology)
  • 김용기 (한국건설기술연구원 그린빌딩연구실) ;
  • 이태원 (한국건설기술연구원 그린빌딩연구실)
  • Received : 2011.11.08
  • Published : 2012.02.10

Abstract

Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.

Keywords

References

  1. Lee, T. W., Kim, Y. K., Park, S. J., and Han, T. S., 2005, A Study on the Optimization of Heating System with Double-Layered Under- Floor Heating Panel, Report of KICT(No. 2005- 010), pp. 23-30.
  2. Lee, B. D., Lee, S. J., Kim, K. S., Oh, S. H., Kim, I. H., Nam, W. D., and Lee, D. W., 2009, A Study on Comparison of Capacity between Wet․Dry Floor Heating Systems, Proceedings of the SAREK 2009 winter annual conference, pp. 133-138.
  3. Ahn, S. J., Lee, S. H., Kim, J. S., and Kim, J. H., 2007, A Study on Performance of Energysaving Ondol Panel using Pulsating Heat Pipe, Proceedings of the SAREK 2007 summer annual conference, pp. 998-1003.
  4. Lee, T. W., Kim, Y. K., and Han, T. S., 2009, A Performance Test of Radiant Heating System Using Heat Pipes with the Double Wick, Report of KICT(No. 2009-050), pp. 35-65.
  5. Han, T. S., Kim, Y. K., Lee, T. W., Jun, S. J., and Moon, W. K., 2009, A Study on the Heating Characteristics of Radiant Floor Panel with Heat Pipes for Heating, Proceedings of the SAREK 2009 winter annual conference, pp. 127- 132.