• Title/Summary/Keyword: Thermal low-pressure

검색결과 599건 처리시간 0.028초

원전 안전 3등급 고밀도 폴리에틸렌 매설 배관 맞대기 열 융착부의 굽힘 피로특성 평가 (Investigation of Bending Fatigue Behaviors of Thermal Butt Fusion in Safety Class III High-Density Polyethylene Buried Piping in Nuclear Power Plants)

  • 김종성;이영주;오영진
    • 한국압력기기공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.40-44
    • /
    • 2015
  • The fatigue behavior of thermal butt fusion in safety class III high-density polyethylene (HDPE) buried piping for nuclear power plants was investigated using load-controlled bending fatigue on four-point bend test specimens. Based on the results, the presence of thermal butt fusion beads was confirmed to reduce the fatigue lifetime in the low- and medium-cycle fatigue regions while having a negligible effect in the high-cycle fatigue regions.

열-나노임프린트 리소그래피 공정에서의 폴리머 유동에 대한 해석적 접근 (Analytical Approach of Polymer Flow in Thermal Nanoimprint Lithography)

  • 김국원;김남웅
    • 한국공작기계학회논문집
    • /
    • 제17권3호
    • /
    • pp.20-26
    • /
    • 2008
  • Nanoimprint lithography(NIL) is becoming next generation lithography of significant interest due to its low cost and a potential patterning resolution of 10nm or less. Success of the NIL relies on the adequate conditions of pressure, temperature and time. To have the adequate conditions for NIL, one has to understand the polymer flowing behavior during the imprinting process. In this paper, an analytical approach of polymer flow in thermal NIL was performed based on the squeeze flow with partial slip boundary conditions. Velocity profiles and pressure distributions of the polymer flow were obtained and imprinting forces and residual thickness were predicted with the consideration of the slip velocity between the polymer and the mold/substrate. The results show that the consideration of the slip is very important for investigating the polymer flow in Thermal NIL.

Effect of a Magnetic Field on Thermal Conductivity of Partially Ionized Gases

  • Yun, Hong-Sik
    • 천문학회지
    • /
    • 제9권1호
    • /
    • pp.1-6
    • /
    • 1976
  • The translational and reactive parts of thermal conductivity of a partially ionized solar magneto-plasma gas have been calculated based on Yun and Wyller's formulation (1972) along with Devoto's theory(1968). The computed results are presented as functions of temperature and pressure for given magnetic field strengths. The results of the calculations show that for most photospheric conditions the magnetic field does not play any important role in characterizing thermal properties of the ionized gas. However, when the gas pressure is low(e.g., P<10 dynes/$cm^2)$) the field becomes extremely effective even if its strength is quite small (e.g., B<0.1 gauss). The reactive part of the thermal transport is found to be very important when the gas is undertaking active ionization.

  • PDF

석탄의 열적 특성과 석탄 내부의 승온 특성과의 상관관계 연구 (Study on the Correlation between Thermal Characteristics and Heat Accumulation in the Coal Pile)

  • 이현동;김재관
    • 한국연소학회지
    • /
    • 제15권4호
    • /
    • pp.58-64
    • /
    • 2010
  • Spontaneous ignition tests of five different coals with non-iso-thermal and iso-thermal test method based on the standard test procedure of NF T20-036 were carried. These five coals included the 2 low rank coals and 3 bituminous coals. Test results showed that the ignition temperatures of all coals at the iso-thermal conditions were higher than that of non-isothermal condition, and those of low rank SM and BR coal in both nonisothermal and isothermal conditions were lower than bituminous AN and CN coals. The chemical species of coals such as oxygen and hematite also plays an important role in enhancing the ignition rate that the ignition temperature of SM coal was lowered. The heat accumulation tendency of five coals inside outdoor stack pile was monitored with emphasis on the change in the temperature of the coal depth in stack pile. In case of low rank BR coal, its temperature inside coal stack pile due to the rate of high heat accumulation and oxidation was $59^{\circ}C$ compared to $51^{\circ}C$ for other SW bituminous coal. And the heat accumulation rate inside coal stack piles was increased with increased the Cp value which it was defined as the specific heat of coal at constant pressure, whereas other factors such as thermal diffusivity and conductivity of coal relatively had less effect on heat accumulation.

Improvement in Characteristics of Thin Film Transistors by High Pressure Steam Annealing

  • Nagasawa, Y.;Yamamoto, N.;Chishina, H.;Ogawa, H.;Kawasaki, Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.333-336
    • /
    • 2006
  • High Pressure Annealing System was developed to improve the characteristics of low-temperature poly-silicon thin film transistors.. (TFTs). The high-pressure steam annealing was applied to the poly-silicon film made by rapid thermal annealing method. The carrier lifetime was investigated by Microwave detection of the Photo-Conductive Decay and the increase of carrier lifetime which indicates the reduction of the defect was observed by high-pressure steam annealing of 1MPa 600C 1hour.

  • PDF

단열 진공유리의 제작 및 열전달계수 측정에 관한 실험적 연구 (Experimental Study on Manufacturing of Insulation Vacuum Glazing and Measurement of the Thermal Conductance)

  • 이보화;윤일섭;곽호상;송태호
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.772-779
    • /
    • 2006
  • Window is a critical component in the design of energy-efficient buildings. To minimize the heat loss, insulation performance of the glazing has to be improved. Manufacturing of vacuum glazing has been motivated by the possibility of making windows of very good thermal insulation properties for such applications. It is made by maintaining vacuum in the gap between two glass panes. Pillars are placed between them to withstand the atmospheric pressure. Edge covers are applied to reduce conduction through the edge. Accurate measurements have been made of the radiative heat transfer, the pillar conduction and the gas conduction using a guarded hot plate apparatus. Vacuum glazing is found to have low thermal conductance roughly below $1W/m^2K$. Among the heat transfer modes of residual gas conduction, conduction through support pillar and the radiative heat transfer between the glass panes, the last one is the most dominant to the overall thermal conductance. Vacuum glazing using very low emittance AI-coated glass has an overall thermal conductance of about $0.7W/m^2K$.

가속노화 시험을 통한 진공단열패널(VIP)의 장기성능 평가 연구 (The Study of Long-Term Performance Evaluation of Vacuum Insulation Panel(VIP) with Accelerated Aging Test)

  • 김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제37권4호
    • /
    • pp.35-47
    • /
    • 2017
  • Energy efficiency solutions are being pursued as a sustainable approach to reducing energy consumption and related gas emissions across various sectors of the economy. Vacuum Insulation Panel (VIP) is an energy efficient advanced insulation system that facilitates slim but high-performance insulation, based on a porous core material evacuated and encapsulated in a barrier envelope. Although VIP has been applied in buildings for over a decade, it wasn't until recently that efforts have been initiated to propose and adopt a global standard on characterization and testing of VIP. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time; more so in building applications. In this paper, the aging of commercially available VIP was investigated experimentally; thermal conductivity was tested in accordance with ISO 8302 standard (guarded hot box method) and long-term durability was estimated based on a non-linear pressure-humidity dependent equation based on study of IEA/ECBCS Annex 39, with the aim of assessing durability of VIP for use in buildings. The center-of-panel thermal conductivity after 25 years based on initial 90% fractile with a confidence level of 90 % for the thermal conductivity (${\lambda}90/90$) ranged from 0.00726-0.00814 (W/m K) for silica core VIP. Significant differences between manufacturer-provided data and measurements of thermal conductivity and internal pressure were observed.

HVOF 열용사 프로세스에서의 연소특성에 관한 수학적 모델링(I): 연소생성물의 화학조성 및 단열화염온도 (Mathematical Modeling of Combustion Characteristics in HVOF Thermal Spray Processes(I): Chemical Composition of Combustion Products and Adiabatic Flame Temperature)

  • 양영명;김호연
    • 한국연소학회지
    • /
    • 제3권1호
    • /
    • pp.21-29
    • /
    • 1998
  • Mathematical modeling of combustion characteristics in HVOF thermal spray processes was carried out on the basis of equilibrium chemistry. The main objective of this work was the development of a computation code which allows to determine chemical composition of combustion products, adiabatic flame temperature, thermodynamic and transport properties. The free energy minimization method was employed with the descent Newton-Raphson technique for numerical solution of systems of nonlinear thermochemical equations. Adiabatic flame temperature was calculated by using a Newton#s iterative method incorporating the computation module of chemical composition. The performance of this code was verified by comparing computational results with data obtained by ChemKin code and in the literature. Comparisons between the calculated and measured flame temperatures showed a deviation less than 2%. It was observed that adiabatic flame temperature augments with increase in combustion pressure; the influence was significant in the region of low pressure but becomes weaker and weaker with increase in pressure. Relationships of adiabatic flame temperature, dissociation ratio and combustion pressure were also analyzed.

  • PDF

Multi Zone Modeling을 이용한 온도 성층화의 효과를 갖는 예혼합압축자기착화엔진의 압력상승률 저감에 대한 모사 (Effect of Thermal Stratification for Reducing Pressure Rise Rate in HCCI Combustion Based on Multi-zone Modeling)

  • 권오석;임옥택
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.32-39
    • /
    • 2009
  • The HCCI engine is a next generation engine, with high efficiency and low emissions. The engine may be an alternative to SI and DI engines; however, HCCI's operating range is limited by an excessive rate of pressure rise during combustion and the resulting engine knock in high-load. The purpose of this study was to gain a understanding of the effect of only initial temperature and thermal stratification for reducing the pressure-rise rate in HCCI combustion. And we confirmed characteristics of combustion, knocking and emissions. The engine was fueled with Di-Methyl Ether. The computations were conducted using both a single-zone model and a multi-zone model by CHEMKIN and modified SENKIN.

감압 플라즈마를 이용한 Escherichia coli 살균 (Low-Pressure Plasma Inactivation of Escherichia coli)

  • 목철균;송동명
    • 산업식품공학
    • /
    • 제14권3호
    • /
    • pp.202-207
    • /
    • 2010
  • 저온에서 미생물을 사멸시킬 수 있는 비열살균기술로 감압 플라즈마를 활용하고자 생성기체별 감압 플라즈마 특성을 비교하고 Escherichia coli 살균효과를 조사하였다. 1 Torr이하로 감압시킨 상태에서 공기, 산소, 질소를 350 mL/min으로 공급하며 플라즈마를 발생시킨 결과 아크발생 없이 균일한 플라즈마가 생성되었다. 감압 플라즈마에 의한 온도 상승은 5분 처리 시 ${10^{\circ}C}$ 내외, 10분 처리 시 ${25^{\circ}C}$ 미만이었으며, 기체 종류별로는 공기, 산소, 질소 순으로 상승도가 낮았다. 감압 플라즈마 5분간 처리로 E. coli는 5 log 이상 감소하였으며, 이후 감소율이 둔화되어 10분간 처리 후 6-7 log 정도의 감소를 보였다. 감압 플라즈마에 의한 E. coli 살균패턴은 살균속도가 높은 초기와 낮은 후기로 구분되는 2단계 1차 반응으로 확인되었으며, 초기 살균속도상수($k_{1}$)는 공기, 산소, 질소 순으로 감소하였다. 감압 공기플라즈마 살균의 작은 D값 또한 식품 표면의 오염도를 낮추기 위한 비열살균기술로서의 가능성을 제시하였다.