• 제목/요약/키워드: Thermal load

검색결과 1,833건 처리시간 0.034초

지하대수층을 이용한 축열시스템의 설계 (I) : 등온해석 (Design of an Aquifer Thermal Energy Storage System (I) : Isothermal Analysis)

  • 송영길;이관수;이태희;김양현
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.102-110
    • /
    • 1993
  • An isothermal analysis was conducted to develop the design tool of an aquifer thermal energy storage system. Taejeon aquifer was chosen for the analysis, and the variation of FRE(Fluid Recovery Efficiency) with respect to the aquifer natural velocity and thermal load were investigated. The analysis results were compared with those of ATESSS(Aquifer Thermal Energy Storage System Simulator) and agreed within 2% of discrepancy. It is recommended, based on the result of this study, that the system may be suitable for a large volume of hot or chill thermal energy storage system, such as for district heating or cooling.

  • PDF

Conceptual design of cryomodules for RAON

  • Kim, Y.;Lee, M.K.;Kim, W.K.;Jang, H.M.;Choi, C.J.;Jo, Y.W.;Kim, H.J.;Jeon, D.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제16권3호
    • /
    • pp.15-20
    • /
    • 2014
  • The heavy ion accelerator that will be built in Daejeon, Korea utilizes superconducting cavities operating in 2 K. The cavities are QWR (quarter wave resonator), HWR (half wave resonator), SSR1 (sing spoke resonator1) and SSR2. The main role of the cryomodule is supplying thermal insulation for cryogenic operation of the cavities and maintaining cavities' alignment. Thermal and structural consideration such as thermal load by heat leak and heat generation, cryogenic fluid management, thermal contraction, and so on. This paper describes detailed design considerations and current results have being done including thermal load estimation, cryogenic flow piping, pressure relief system, and so on.

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

Experiments on the Thermal Stratification in the Branch of NPP

  • Kim Sang Nyung;Hwang Seon Hong;Yoon Ki Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1206-1215
    • /
    • 2005
  • The thermal stratification phenomena, frequently occurring in the component of nuclear power plant system such as pressurizer surge line, steam generator inlet nozzle, safety injection system (SIS), and chemical and volume control system (CVCS), can cause through-wall cracks, thermal fatigue, unexpected piping displacement and dislocation, and pipe support damage. The phenomenon is one of the unaccounted load in the design stage. However, the load have been found to be serious as nuclear power plant operation experience accumulates. In particular, the thermal stratification by the turbulent penetration or valve leak in the SIS and SCS pipe line can lead these safety systems to failure by the thermal fatigue. Therefore in this study an 1/10 scaledowned experimental rig had been designed and installed. And a series of experimental works had been executed to measure the temperature distribution (thermal stratification) in these systems by the turbulent penetration, valve leak, and heat transfer through valve. The results provide very valuable informations such as turbulent penetration depth, the possibility of thermal stratification by the heat transfer through valve, etc. Also the results are expected to be useful to understand the thermal stratification in these systems, establish the thermal strati­fication criteria and validate the calculation results by CFD Codes such as Fluent, Phenix, CFX.

Effect of thermal laser pulse in transversely isotropic Magneto-thermoelastic solid due to Time-Harmonic sources

  • Lata, Parveen;Kaur, Iqbal;Singh, Kulvinder
    • Coupled systems mechanics
    • /
    • 제9권4호
    • /
    • pp.343-358
    • /
    • 2020
  • The present research deals with the time-harmonic deformation in transversely isotropic magneto thermoelastic solid with two temperature (2T), rotation due to inclined load and laser pulse. Generalized theory of thermoelasticity has been formulated for this mathematical model. The entire thermo-elastic medium is rotating with uniform angular velocity and subjected to thermally insulated and isothermal boundaries. The inclined load is supposed to be a linear combination of a normal load and a tangential load. The Fourier transform techniques have been used to find the solution to the problem. The displacement components, stress components, and conductive temperature distribution with the horizontal distance are computed in the transformed domain and further calculated in the physical domain using numerical inversion techniques. The effect of angle of inclination of normal and tangential load for Green Lindsay Model and time-harmonic source for Lord Shulman model is depicted graphically on the resulting quantities.

열충격에 의한 열차폐 코팅재의 기계적 거동 변화 (Changes in the Mechanical Behavior of Thermal Barrier Coatings Caused by Thermal Shock)

  • 장빈;이기성;김태우;김철
    • 한국재료학회지
    • /
    • 제27권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This study investigates changes in the mechanical behaviors, especially hardness and indentation load-displacement curves, of thermal barrier coatings (TBCs) brought about by thermal shock. The TBCs on the Nickel-based bondcoat/superalloy was prepared with diameters of 25.4 mm and $600{\mu}m$ thickness. The results of thermal shock cycling test from $1100^{\circ}C$ of the highest temperature indicate that the thermal shock do not influence on the mechanical behavior, but a continuous decrease in porosity and increase in hardness were observed after 1200 thermal shock cycles; these changes are believed to be due to sintering of thermal barrier coating materials. The results that no degradation in the indentation load-displacement curves indicate that the coating shows good thermal shock resistance up to 1200 cycles at $1100^{\circ}C$ in air.

인공위성 열지향오차 해석 (Thermal Pointing Error Analysis of Satellite)

  • 김선원;김진희;이장준;황도순
    • 한국위성정보통신학회논문지
    • /
    • 제2권1호
    • /
    • pp.21-26
    • /
    • 2007
  • 탑재된 광학카메라 또는 영상레이더를 이용하여 지구관측 임무를 수행하는 저궤도 지구관측위성은 지상으로부터 수 백 km 고도의 궤도상에서 극심한 열하중을 받게 된다. 이로 인하여 구조체의 열변형이 발생하게 되고 결과적으로 구조체에 장착된 탑재체가 지상의 원하는 지점을 관측하지 못하는 문제점이 발생하게 된다. 이러한 열변형에 의한 탑재체의 지향방향의 변화를 열지향오차라고 한다. 열지향오차 해석은 열해석, 온도값 변환 및 구조해석의 세 단계로 수행된다. 본 논문에서는 열지향오차 해석을 통하여 위성의 임무수행 가능성을 기술하는것을 목적으로 하였다.

  • PDF

금속패널지붕의 열교 방지를 위한 열교차단장치 개발 및 적용효과 분석 (Study of Thermal Bridge Breaker to Prevent the Thermal Bridge Effect on Metal Panel Roofs)

  • 김선호;정채봉;이충식;김종민;김병철
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.32-37
    • /
    • 2021
  • To realize a zero-energy building, a technology that minimizes the energy loss due to thermal bridges by preventing their formation is emerging as an important design factor. In this study, we develop a thermal bridge breaker to prevent thermal bridging in a metal panel roof and attempt to analyze the effects of its application. To this end, we fabricated a thermal bridge breaker and analyzed it in terms of its strength and heat-transfer characteristics, in addition to conducting a load simulation. The thermal bridge prevention effect of the developed thermal bridge breaker improved the insulation performance of the metal panel roof, and the results of a cooling/heating peak load simulation performed by applying the heat transmission resistance test results to a building proved the existence of this effect.

집단에너지 열연계운전 분석을 위한 시뮬레이터 개발 (Development of a simulation program for the analysis of a thermal networking operation in District Heating)

  • 임용훈;박화춘;정모
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.825-832
    • /
    • 2008
  • A simulation program is developed for analysing thermal networking process between the District heating and the CES(Community Energy Supply) systems. The effects of thermal networking on the District heating facilities previously being operated are implemented using mathematical correlations in terms of the fuel consumption and energy load such as heating and electricity. The operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features of the newly developed program in simulation of thermal networking process in district heating is described in terms of the reliability and the easiness for operating it etc.

  • PDF

응답계수(應答係數)를 이용(利用)한 건물벽에서의 열부하(熱負荷) 계산(計算) (Thermal Load Calculations on Stud-Frame Walls by Response Coefficient Method)

  • 황영규;박이동
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.357-368
    • /
    • 1988
  • An application of thermal response coefficient method for obtaining thermal load on stud-frame walls in a typical house is presented. A set of stud-frame walls is two-dimensional heat conduction transients with composite structure. The ambient temperature on the right-hand face of the stud-frame walls is a typical day-cycle input and the room temperature on the left-hand face is a constant input. The desired output is thermal load at the left-hand face. The time-dependent ambient temperature is approximated by a continuous, piecewise-linear function each having one hour interval. The conduction problem is spatially discretized as 8 computer modelings by finite elements to obtain thermal response coefficients. The discretization and round-off errors can be neglected in the range of adequate number of nodes. A 60-node discretization is recommended as the optimum model among 8 computer modelings. Several sets of response coefficients of the stud-frame walls are generated by which the rate of heat transfer through the walls or some temperature in the walls can be calculated for different input histories.

  • PDF