• Title/Summary/Keyword: Thermal extraction efficiency

Search Result 49, Processing Time 0.03 seconds

The Study on Prediction of Hot Water Extraction in a Thermal Energy Storage System (축열시스템의 온수이용 예측에 관한 연구)

  • Cho, W.;Pak, E.T.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 1998
  • In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load for demand. Lately, practical use of thermal energy storage system and attention to essential use of energy have been increased. From this point of view, especially, a study about the energy extraction process from a storage tank is necessary. So in this study, useful rate of hot water and hot water extraction efficiency was analysed respect to dynamic and geometric parameters dominating the hot water extraction process.

  • PDF

Reduced-Scale Experiments of the Partial Smoke Extraction System in Tunnel Fires (풀화재를 이용한 터널화재 부분배연 모델실험)

  • Lee, Eui-Ju;Yoo, Yong-Ho
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.58-64
    • /
    • 2006
  • Smoke extraction in tunnel fire is investigated experimently with thermal model. The object is a immersed tunnel, of which the partial extraction system exists between the tubes. The model tunnel is measured 12 m long, 0.5 m wide and 0.35 m high. The fire is simulated to pool fire and the size corresponds to full scale fire of 5 MW based on Froude modeling. The performance of partial extraction system is determined under two ventilations, natural and longitudinal ones. The results show that compared with longitudinal ventilation, the smoke extraction efficiency of natural ventilation is increased about 30% because of smoke stratification in tunnel. Also the efficiency is identical to the iso-thermal model. The results will be help for activation of the ventilation system in emergency such as in the event of tunnel fires.

Optimization Study on the Performance Analysis of Organic Rankine Cycle for Characteristics of Low Temperature Heat Sources (저온열원의 특성에 따른 ORC 성능해석 최적화 연구)

  • Eom, Hong-Sun;Yoon, Cheon-Seog;Kim, Young-Min;Shin, Dong-Gil;Kim, Chang-Gi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-60
    • /
    • 2012
  • Optimization procedures of performance analysis for ORC(Organic Rankine Cycle) system are established to the characteristics of low temperature heat sources such as open-type and closed-type. Effective heat recovery and heat extraction related to maximum power of the cycle as well as heat quality and thermal efficiency must be considered in the case of the open-type low temperature heat source. On the other hand, in the case of the closed-type low temperature heat source, only thermal efficiency is important due to constant heat input. In this study, thermal efficiency and exergy efficiency representing a level of close to Carnot cycle are studied, as useful index for the optimization of the ORC system. To validate the results of cycle analysis, those are compared with appropriate experimental data of ORC system as a thermal efficiency point of view.

Foreground Extraction in Thermal Videos Based on Selective Histogram Bins (선택적 히스토그램 빈 기반 열화상 영상 전경 추출)

  • Yu, Gwang-Hyun;Zaheer, Muhammd Zaigham;Kim, Jin-Young;Sin, Do-Seong
    • Journal of Digital Contents Society
    • /
    • v.19 no.4
    • /
    • pp.757-770
    • /
    • 2018
  • Foreground extraction is the most significant step in thermal imaging based surveillance systems. This step needs to be efficient in terms of time and memory consumption in order for the system to provide real time results but usually this efficiency reciprocates with the accurateness of the ROI detection. In this study, novel selective histogram bins based two background & foreground separation approaches for thermal videos processing have been proposed which exploit the temporal-consistency property of the thermal images in a given environment and can save over 80% memory than their simplest counterpart temporal median filtering.

Thermally Stratified Hot Water Extraction (태양열 온수 저장조의 성층 온수 추출에 관한 연구)

  • Pak, Ee-Tong;Jeong, Un-Chul;Sung, Sang-Woo
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.34-40
    • /
    • 1991
  • Thermal stratification enhancement for the higher extraction efficiency of hot water storage tank was experimentally studied with transparent fiber glass cylindical tank($350{\ell}$, D=516mm, H=1680mm). Height to diameter ratio (H/D =1,2,3), flow rate(Q= 8,10,12LPM), inlet-outlet temperature differences(${\Delta}T=20,25,30^{\circ}C$), and geometry of inlet-outlet port were the parameters. In particular, three kind of distributors were used for geometry of inlet-outlet port. As a result, it was possible to get extraction efficiency of 95% by using the distributor having variable diameter but keeping a constant diameter of perforation. So it is recommendable to design the distributor so that the main pipe decrease in diameter toward the dead end.

  • PDF

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

Light extraction efficiency enhancement on organic light-emitting device by microlens array attachment: a systematic approach

  • Hsu, Sheng-Chih;Chen, Kuan-Yu;Lin, Hoang-Yan;Lee, Jiun-Haw;Lin, Chung-Yu;Wei, Mao-Kuo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1819-1824
    • /
    • 2006
  • A microlens arrays formed by thermal reflow method is attached to an OLED device and the light extraction efficiency which includes luminance and power information is determined by adjusting the area ratio and the height ratio.

  • PDF

Extraction Method of Carotenoios from Rhodotorula glutinis (Rhodotorula glutinis로 부터 Carotenoios의 추출방법)

  • 김의용;박평규
    • KSBB Journal
    • /
    • v.17 no.1
    • /
    • pp.44-48
    • /
    • 2002
  • An efficient method of extraction for carotenoids in Rhodotorula glutinis KCTC 7989 was developed. Major carotenoids produced were identified as torularhodin of 61.7%, $\beta$-carotene of 28.8%, and torulene of 9.5%. HCI treatment, as a pretreatment on cell, was necessary to carry out together with thermal treatment unlike DMSO pretreatment. The choice of solvent had an important effect on the composition of carotenoids extracted: benzene and chloroform were effective for the extraction of torularhodin, especially. However, diethyl ether was most effective for the extraction of total carotenoids. Freeze dried type cells showed high efficiency value for the extraction of carotenoids, in compared with dried and wet type cells.

Electrochemically polyaniline-coated microextraction needle for phthalates in water

  • Hwang, Yura;Lee, Yelin;Ahn, Soyoung;Bae, Sunyoung
    • Analytical Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.76-85
    • /
    • 2020
  • A stainless-steel needle (Hamilton 90022, 22 gauge, 718-㎛ o.d., 413-㎛ i.d., 51-mm length, bevel tip) with an electrochemically coated polyaniline layer having a microbore tunnel was newly prepared as a device for headspace in-needle microextraction. For designing the needle, the polyaniline layer length was optimized, and to evaluate the extraction efficiency for polycyclic aromatic hydrocarbons, numerous cyclic voltammetry scans were conducted. In addition, the optimization of the analytical conditions (including the adsorption and desorption parameters) and the validation of the analytical method were conducted. The optimized adsorption and desorption conditions were 40 ℃ for 30 min and 230 ℃ for 60 s, respectively. Finally, in this study, a polyaniline layer was electrochemically deposited on the in-needle surface, and it exhibited good thermal stability. The needle with the polyaniline layer was repeatedly used more than 200 times during this study. This method has some advantages in terms of the extraction time, extraction efficiency, and analysis cost.