• 제목/요약/키워드: Thermal discharge

검색결과 631건 처리시간 0.032초

A Study on Synthetic Failure-finding Method for Electrical and Thermal Degradation of Polymer Insulator by Surface Discharge

  • Lee, Kang-Won;Jang, Dong-Uk;Park, Cheol-Hyun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권3호
    • /
    • pp.143-146
    • /
    • 2007
  • Polymer insulators are used widely in variable fields for high voltage insulation and separating people from high voltage charging parts for safety and also supporting overhead power line in electric railway. But it may be broken down by tracking path resulting from continuous surface discharge. This paper has investigated synthetically both the characteristics of electrical aging using precision CT(current transformer) and the thermal aging using thermography method. Electrical aging was analyzed for time-frequency region and thermal aging was illustrated by image processing method. This synthetic method may be an appropriate one to evaluate the surface degradation of polymer insulator.

저온 플라즈마와 첨가제를 이용한 NOx 제거실험 및 수치해석 (The Study of NOx Removal Experiment and Numerical Analysis Modeling using Chemical Addition with Non-thermal Plasma)

  • 채재우;문승일;김관영;김상우;박용광;이창민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.720-725
    • /
    • 2000
  • To remove harmful gases from combustion exhaust gases. fundamental study on NOx removal using pulse corona discharge has been performed through experiments and simulations. The energy consumption should be decreased in order to apply non-thermal plasma technology to industry process. This work summarized the effects of $H_2O$ and Hydrocarbon additive in NOx removal efficiency. The Radical program is used to simulate high voltage discharge and the process of NOx removal. At last, experimental results were compared with simulation results to verify the reliability of this program.

  • PDF

변압기 열열화 모의 고장어 대한 유중가스 분포연구 (A study on gas dissolved distribution in oil for simulated transformer thermal faults)

  • 선종호;이상화;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1800-1802
    • /
    • 2003
  • This paper describes a study on gas dissolved distribution in oil for simulated transformer thermal faults. Experimental chamber was setup for simulation of transformer thermal faults or discharge in oil with or without insulation paper. The experimental results showed that dissolved gases in oil excluding the paper did not evolved upto $150^{\circ}C$. Hereafter the planned gas dissolved analysis will be continuously carried out for transformer fault conditions with or without insulation paper related to water absorption, arc and partial discharge.

  • PDF

태안화력발전소 주변 암반조간대에 서식하는 대형저서동물의 종조성 및 군집구조에 미치는 온배수의 영향 (Thermal Discharge Effects on the Species Composition and Community Structure of Macrobenthos in Rocky Intertidal Zone Around the Taean Thermoelectric Power Plant, Korea)

  • 정윤환;김형준;박흥식
    • Ocean and Polar Research
    • /
    • 제40권2호
    • /
    • pp.59-67
    • /
    • 2018
  • This study was conducted to understand the distribution and changes of macrobenthos on rocky intertidal areas around Taean thermoelectric power plant, Also, the purpose of this study was to produce a base-line data on the changes in water temperature due to the operation of the power plant and to understand its thermal impact on the macrobenthic community on intertidal rocky bottoms. A field survey was seasonally conducted at 3 rocky intertidal sites around the Taean thermal power plant. There was no seasonal difference in the community parameters such as number of species, mean density, biomass and species diversity during the study period. The major dominant species were Chthamalus challenger, Littorina brevicula, Crassostrea gigas. In comparison with previous study, thermal discharge in the study area did not significantly affect the distribution of dominant species. The structure of the macrobenthic community revealed that there were showed 3 different faunal groups depending on the difference in the mean density of major dominant species. The result of SIMPER analyses to determine which species were the main contributors to the differences between each community, C. challenger, Lottia spp. And Mytilus galloprovincialis, etc., revealed that there was showed a significant difference between each group. The abundance of M. galloprovincialis, showed a significant difference between faunal groups.

환경영향평가와 사후환경조사의 비교에 관한 연구 - 태안화력발전소 사례분석 - (The Study on the Improvement of Environmental Assessment Method through Analysis of Environmental Investigation Results of Taean Thermal Power Plant)

  • 전상기;이성철
    • 환경영향평가
    • /
    • 제9권1호
    • /
    • pp.61-74
    • /
    • 2000
  • This study compares the results of environmental impact assessment with the results of post-environmental investigation, using the case of Taean thermal power plant construction. The atmospheric and water qualities were not greatly changed before and after the construction of the power plant. However, the site of the highest concentration predicted by the atmospheric quality modeling in environmental impact assessment was different from that after operation of 4 power plants. There was also a difference in the diffusion range of thermal discharge water between the measured result(1km) and the predicted value(1.5km) with the model. Thus, environmental impact evaluation should be based on long-term (more than a year) environmental monitoring data. For the modeling of atmospheric quality and numerical thermal discharge water diffusion, appropriate models for each plant should be selected and the numerical modeling should be accompanied by computer simulation, wind tunnel test, etc. Moreover, environmental evaluation should focus more on the degree of impact on surroundings than the prediction of changes in surroundings caused by operation of plants.

  • PDF

Development of a Plasma Training Lab kart: System Setup and Numerical Simulation

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제26권6호
    • /
    • pp.195-200
    • /
    • 2017
  • A mobile lab kart for plasma training is developed with a high vacuum pumping system, vacuum gauges and a glass discharge tube powered by a high voltage transformer connected to a household 60 Hz line. A numerical model is developed by using a commercial multiphysics software package, CFD-ACE+ to analyze the experimental data. Simulations for argon and nitrogen were carried out to provide fundamental discharge characteristics. Variations of the kart configuration were demonstrated: a glass tube with three electric probes, optical emission spectrometer attachment and infra red thermal imaging system to give more detailed analysis of the discharge characteristics.

AHU 토출온도에 따른 일반 공조시스템의 에너지 소비량 및 실내 온열환경 분석 (Energy Consumption and Thermal Comfort Assessment of Conventional Forced-air System According to AHU Discharge Air Temperature)

  • 김민지;연상훈;이광호
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.51-57
    • /
    • 2018
  • Recently, global warming has been a serious issue on the worldwide, and the importance of energy conservation is increasing. In most buildings, energy consumption increases due to cooling, heating, and ventilation. Because of these issues, researches have been carried out to reduce building energy. However, in most conventional forced-air system, the guidelines for the Air Handling Unit (AHU) discharge air temperature are not fully established. The purpose of this study is to assess the impact of AHU discharge air temperature, which is one of the important control variables, on the overall energy consumption and thermal comfort characteristics by modeling conventional forced-air system using EnergyPlus. In addition, recommendations for energy reduction in conventional AHU is provided.

Plasma Propagation Speed and Electron Temperature of Atmospheric Pressure Non-Thermal Ar Plasma Jet

  • 한국희;김동준;김현철;김윤중;김중길;이원영;나야나;조광섭
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.512-513
    • /
    • 2013
  • Space and time resolved discharge images from an atmospheric pressure non-thermal Ar plasma jet have been observed by a ICCD camera to investigate the electron temperatures. Plasma jet device consisting of a syringe electrode inserted into a glass tube has been introduced. A high voltage is applied to the syringe electrode. The syringe needle has an outer diameter of 1.8 mm, an inner diameter of 1.3 mm, and a total length of 39.0 mm. The needle is inserted into a glass tube of outer diameter 2.4 mm and inner diameter 2.0 mm, and a total length of 80.0 mm. The Ar plasma propagation speed on the cathode has been shown to be about 2.1 km/s at input discharge voltage of 3.6 kV, discharge current of 19.9 mA and driving frequency of about 45 kHz. Particularly, the electron temperature in plasma jet were found to be about 1.8 eV at input discharge voltage of 3.6 kV and driving frequency of 45 kHz, respectively.

  • PDF

정전기 방전에 의해 제조된 흑연박리 그래핀 첨가 폴리이미드 막의 열전도 향상 (Thermal Conductivity Enhancement of Polyimide Film Induced from Exfoliated Graphene Prepared by Electrostatic Discharge Method)

  • 임채훈;김경훈;안동해;이영석
    • 공업화학
    • /
    • 제32권2호
    • /
    • pp.143-148
    • /
    • 2021
  • 본 연구에서는 폴리이미드(polyimide; PI) 막(film)의 열전도도를 향상시켜 그 응용성을 확대하고자, 정전기 방전법을 이용하여 흑연봉으로부터 그래핀을 제조하고 제조된 그래핀을 첨가하여 폴리아믹산(polyamic acid; PAA) 전구체로부터 200 ㎛두께의 폴리이미드 기반 열전도 막을 제조하였다. 정전기 방전 기법으로 생산된 그래핀은 라만, XPS, TEM 등을 이용하여 물성을 평가하였다. 제조된 그래핀은 라만 스펙트럼 분석 결과 ID/IG 값이 0.138이며, XPS 분석 결과 C/O 비율이 24.91로 구조적, 표면화학적으로 우수한 물성을 나타내었다. 또한, 흑연 박리 그래핀의 첨가량에 따라 폴리이미드 막의 열전도도는 지수함수적으로 증가하였으며, 그래핀 함량을 40% 초과 시에는 폴리이미드 막을 제조할 수 없었다. 그래핀을 폴리아믹산 중량 대비40 wt% 첨가하여 제조된 폴리이미드 막의 열원반(hot disk) 열전도도는 51 W/mK를 나타내었으며, 순수한 폴리이미드 막의 열전도도(1.9 W/mK)보다 크게 향상되었다. 이 결과는 정전기 방전기법으로 제조된 박리 그래핀의 우수한 물성에 기인한 것으로 판단된다.

와이어 방전가공에서 전류파형이 양극침식에 미치는 영향 (Influence of Current Waveform on Anode Erosion in Wire Electric Discharge Machining)

  • 조성산;오진혁
    • 한국정밀공학회지
    • /
    • 제18권7호
    • /
    • pp.127-133
    • /
    • 2001
  • The effects of triangular and rectangular discharge current waveforms on anode erosion in wire electric discharge machining is investigated based on heat transfer analysis of half-space subject to time and space-dependent heat flux. The thermal load on the anode is simulated by a hear flux that is calculated from time-dependent discharge channel radius and energy. Evolution of the melting front during discharge, the molten volume at the experimental result for qualitative verification of the analysis. It is demonstrated that the triangular current waveform is more efficient in eroding the anode than the rectangular one.

  • PDF