Energy Consumption and Thermal Comfort Assessment of Conventional Forced-air System According to AHU Discharge Air Temperature

AHU 토출온도에 따른 일반 공조시스템의 에너지 소비량 및 실내 온열환경 분석

  • Kim, Min Ji (Graduate School, Hanbat National University) ;
  • Yeon, Sang Hun (Graduate School, Hanbat National University) ;
  • Lee, Kwang Ho (Department of Architectural Engineering, Hanbat National University)
  • 김민지 (국립한밭대학교 대학원 건축공학과) ;
  • 연상훈 (국립한밭대학교 대학원 건축공학과) ;
  • 이광호 (국립한밭대학교 건축공학과)
  • Received : 2017.09.22
  • Accepted : 2017.11.28
  • Published : 2018.02.10

Abstract

Recently, global warming has been a serious issue on the worldwide, and the importance of energy conservation is increasing. In most buildings, energy consumption increases due to cooling, heating, and ventilation. Because of these issues, researches have been carried out to reduce building energy. However, in most conventional forced-air system, the guidelines for the Air Handling Unit (AHU) discharge air temperature are not fully established. The purpose of this study is to assess the impact of AHU discharge air temperature, which is one of the important control variables, on the overall energy consumption and thermal comfort characteristics by modeling conventional forced-air system using EnergyPlus. In addition, recommendations for energy reduction in conventional AHU is provided.

Keywords

References

  1. Im, H. J., Jung, S, K., and Won, D. H., 2013, An Analysis of the Impact of Global Warming on Residential Energy Consumption : Focused on the Case of Electricity Consumption, Korean Energy Economic Review, Vol. 12, No. 2, pp. 33-58
  2. Korea Energy Economics Institute, 2014, Energy Consumption Survey.
  3. Yu, S. W. and Cho, Y. H., 2011, A Study on Reset of Minimum Airflow of VAV Terminal Boxes for Improving Energy Efficiency in the Office Building, Journal of Korea Institute of Architectural Sustainable Environment and Building System, Vol. 5, No. 4, pp. 273-279.
  4. Cho, Y. H. and Ahn, D. J., 2011, A Study in the Improving Energy Efficiency through Retro-Commissioning, Journal of The Architectural Institute of Korea Planning & Design, Vol. 27, No. 9, pp. 301-308.
  5. The U. S. Department of Energy, 2016, EnergyPlus Input Output Reference, The Encyclopedic Reference to EnergyPlus Input and Output.
  6. Jang, H. I., Kwak, H. J., and Suh, S. J., 2012, Comparison on the Indoor Thermal Environment and Energy Consumption of VAV System by PMV Control, Proceeding of The Society of Air-conditioning and Refrigerating Engineers of Korea 2012 Winter Conference, pp. 101-104.