• Title/Summary/Keyword: Thermal and pollution performance

Search Result 66, Processing Time 0.022 seconds

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio (난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토)

  • SEO, JUNSUN;KIM, YOUNG-JIC;PARK, JUNKYU;LEE, CHANG-EON
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.6
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

Effect of Waste Heat Recovery Condensing Boiler with Condensed Water Recirculation Function (응축수 순환이 폐열회수 응축형 보일러 성능에 미치는 영향)

  • Keum, Kuk Bin;Kim, Sooik;Yu, Byeong-Hun;Lee, Chang Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.201-204
    • /
    • 2015
  • Recently, energy excessive consumption and environmental pollution are the social issued. The most efficient way to solve both energy excessive consumption and environmental pollution is existing combustion system improved. This study was part of the assume and commercial used existing waste heat recovery condensing boiler to low emission performance for exhaust gas recirculation(EGR) and thermal efficiency rise by applying the condensed water recirculation(CWR) conducted. The researchers applied the EGR and CWR develop a new concept for the condensed water recirculation waste heat recovery condensing boiler. Waste heat recovery condensing boiler applied to the condensed water recirculation thermal efficiency of the same conditions was increased by about 4.8~5.5% and pollution emission also decreased.

  • PDF

An Analysis Study for Thermal Design of ISG (Integrated Starter & Generator) for Hybrid Electric Vehicle (하이브리드 차량용 ISG(Integrated Starter Generator)의 방열 설계를 위한 해석적 연구)

  • Kim, Dae Geon;Kim, Sung Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.120-127
    • /
    • 2013
  • Hybrid electric vehicles have applied electric parts for saving fuel consumption and reducing levels of environmental pollution. Electrification of automobiles is indispensable for entering into global market because of enhanced environment restriction. ISG (Integrated Starter & Generator) system is one of main electric parts and can improve fuel efficiency more than other components by using Idle Stop & Go function and regenerative braking system. However, if ISG motor and inverter work under the continuously high load condition, it will make them the decrease of performance and durability. So the ISG motor and inverter need to properly design the cooling system of them. In this study, we suggested the enhancement points by modifying the thermal design of ISG motor and then confirmed the improvement of the cooling performance.

Development of High Efficiency Solar Power Generation with Two-axis Tracking Control (양축 추적제어에 의한 고효율 태양열 발전시스템의 개발)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1721-1726
    • /
    • 2011
  • Recently, interest in renewable energy is increased due to exhaustion of fossil fuel and environmental pollution all over the world, therefore the solar power generation using solar energy is many researched. The solar power generation is required solar tracking control and high concentration solar thermal collector because generation performance is depended on concentrator efficiency. This paper proposes high efficiency solar power generation with two-axis tracking control using dish-type solar thermal collector that has excellent thermal collector performance and tracking algorithm that can be accurately tracked solar position. This paper proves validity through analysis with accuracy of tracking algorithm and generating efficiency.

Utilizability of Shell Powder as Wall Coatings for Thin Textured Finishes (건축용 벽 바름재로서 패각분말의 활용성 연구)

  • Jeon, Ji-Hyeon;Kook, Chan
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.33-40
    • /
    • 2007
  • 0.4 Million tons of shell powder have been disused as waste in KOREA and caused severe environmental pollution though shell powder can be utilized in real life for many ways. It is impending problem to recycle shell powder as it requires high expense for burying and temporary outside heap and causes severe environmental pollution being a main factor of ocean waste. To suggest the basic data for development of eco-friendly and high-function Wall Coatings Thin Textured Finishes, a wall coating sample was applied to indoor walls of a mock-up and temperature and humidity were measured to assess the thermal performance of it, and a survey of preference for the color sense and feel of the materials with a movie of specimens. The results of the study are following; 1) High insulation performance is shown from the assessment result of the room polystyrene board adhered on the walls then high humidity controlling performance is shown from that of the room polystyrene board coated by shell powder. This point out that shell powder has superiority for humidity controlling. 2) The result of thermal and humidity assessment shows that shell powder makes up for thermal conduction of the polystyrene board and same result can be expected from the assessment with materials which has similar thermal characteristics with polystyrene.3) Ranking of preferred specimens is; 1st Case 13, 2nd Case 17, 3rd Case 16, and 4th Case 12. Preferred shell powder was the ark shell. Preferred powder for plaster was the powder mixed with that sifted by 0.8mm, 100mesh and 40mesh, and for spray was the fine powder mixed with that sifted by 100mesh and 40mesh.

A Study on Engine Performance Characteristics with Variation of Operating Condition in Diesel Engine (디젤엔진의 운전인자 변화에 따른 엔진의 성능특성에 관한 연구)

  • Kim, GiBok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.645-651
    • /
    • 2020
  • In this study, It is necessary that we should study on more effective use about reciprocating engines because there are huge increase of air pollution. Diesel Engine is operated by injecting fuel directly to combustion chamber with high pressure. Diesel Engine has greater thermal efficiency and durability than Gasoline Engine. Also, Diesel Engine emitted low harmful exhaust witch caused by Gasoline Engine. There are many ways to improve of performance and decrease of harmful exhaust by controlling injection timing, changing amount of fuel and engine speed and so on. Especially, development and application of common rail direct injection Engine cause the increase of thermal efficiency by controlling a various of operating conditions. In this study we analyze characteristics of performance by changing a various of operating conditions.

Characteristics of Atmospheric Concentrations of Toxic Volatile Organic Compounds in Korea ( I ) - Evaluation of Sampling and Analytical Methodology (국내 대기 중 독성 휘발성 유기화합물의 오염 특성(I) - 측정 방법론 평가 -)

  • 백성옥;김미현;김수현;박상곤
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.95-107
    • /
    • 2002
  • This study was designed to investigate the characteristics of atmospheric concentrations of toxic volatile organic compounds (VOCs) in Korea. Target compounds included 1,3-butadiene, aromatics such as BTEX, and a number of carbonyl compounds. In this paper, as the first part of the study, the performance of sampling and analytical methods was evaluated for the measurement of selected VOCs and carbonyl compounds in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis, while carbonyls by the DNPH-silica cartridge sampling with HPLC analysis. The methodology was investigated with a wide range of performance criteria such as repeatability, linearity. lower detection limits, collection efficiency, thermal conditioning, breakthrough volume and calibration methods using internal standards. In addition, the sampling and analytical methods established in this study were applied to real field samples duplicately collected in various ambient environments. Precisions for the duplicate samples appeared to be comparable with the performance criteria recommended by USEPA TO-17. The overall precision of the sampling and analytical methods was estimated to be within 20 ∼ 30% for major aromatic VOCs such as BTEX, whereas the precision for major carbonyl compounds such as formaldehyde and acetaldehyde was within 10 ∼ 20% for field samples. This study demonstrated that the adsorbent sampling and thermal desorption method can be reliably applied for the measurement of BTEX in ppb levels frequently occurred in common indoor and ambient environments.

An Experimental Study on the Optimization of Performance Parameter for Membrane Based Dehumidification and Air Conditioning System (분리막 제습공조 시스템의 성능변수 최적화를 위한 실험적 연구)

  • Jang, Jeachul;Kang, Eun-Chul;Jeong, Siyoung;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.75-80
    • /
    • 2016
  • There are three types of dehumidification systems : refrigeration dehumidification method, desiccant dehumidification method and hybrid dehumidification method. The first method involves removing moisture by condensation below the dew point, the second method involves absorption by a desiccant material and the last is an integration method. However, the refrigeration dehumidification system consumes too much power and controlling the humidity ratio is difficult. The desiccant dehumidification system uses less power but it has problems of environmental pollution. The hybrid dehumidification system has the disadvantage of a high initial cost. On the other hand, the energy consumption of the membrane based dehumidification system is lower than for the refrigeration dehumidification system. Also, it is an environmentally friendly technology. In this study, the performance parameters are evaluated for the dehumidification system using a hollow fiber membrane. Available area, duct side dry-bulb temperature, sweep gas flux (flow rate) and LMPD (Log Mean Pressure Difference) were used as the performance parameters.

A Study on the Evaluation of Apartment Building Energy Efficiency Rating Considering the Performance of Thermal Insulators and Window glasses (창호 및 단열재 변수에 따른 공동주택 에너지효율등급 평가 사례)

  • Kim, Han-Soo;Yun, Hae-Dong;Byun, Woon-Seob
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.706-711
    • /
    • 2009
  • Energy shortage and environmental pollution caused by fossil fuels are very serious problem. Especially buildings have consumed more and more energy, and buildings are spend up to 25% of total energy consumption. So we should prepare alternatives to save energy in buildings. In apartment houses, The efficiency of thermal insulators and window glasses is very important to curtail heating energy. In this study, the energy rating of Apartment building is evaluated by applying various thermal insulators and window glasses.

  • PDF