• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.04 seconds

A Study on The Pulsating Combustion of Premixed Gas in a Tube with a Honeycomb (다공성 물질에 의한 예혼합기의 맥동연소에 관한 연구)

  • 권영필;이동훈;현길학
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.676-684
    • /
    • 1990
  • This study is on the pulsating combustion of premixed gas in a Rijke type combustor made of a honeycomb flame holder in a tube. Modelling for the onset condition of the oscillation is made by the ratio of the acoustic power generation based on the analysis of heat transfer to the power loss due to the thermoviscous dissipation and radiation. Experiment is performed for the characteristics of acoustic, thermal and combustion. It is shown that the theoretical modelling for the oscillation may be used as a limit condition. And the combustion analysis for the acoustic power generation is needed for better prediction of the onset condition. Experimental result shows that, by pulsation, the flame length is shortened and the flame temperature is decreased with increase in the heat transfer coefficient. The NO$_{x}$ concentration in the exhaust gas is significantly reduced by pulsation and the concentration of unburned hydrocarbon shows a little increase.e.

Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method (건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석)

  • Park, Jaejoong;Myeong, Jemin;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

Thermal Characteristics of Polyvinylchloride in Combustion Reaction Using TGA (TGA를 이용한 폴리염화비닐의 연소반응에서의 열적 특성 연구)

  • Seo, Su-Eun;Kang, Yun-Jin;Min, Cho-Young;Bae, Dong-Chul;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.3
    • /
    • pp.217-226
    • /
    • 2009
  • The combustion reaction of polyvinylchloride(PVC) was investigated using a thermogravimetric technique under an air atmosphere condition at several heating rates from 10 to $50^{\circ}C$/min. To obtain information on the kinetic parameters, the dynamic thermogravimetric analysis curve and its derivative were analyzed by a variety of analytical methods such as Kissinger, Friedman, Chatterjee-Conrad, Ozawa and Coats-Redfern methods. The combustion reaction of PVC proceeded in two steps; the first step was caused by the dehydrochlorination process in PVC, and the second step by the combustion of polyene. The comparative works for the kinetic results obtained from various methods should be performed to determine the kinetic parameters, because there are tremendous differences in the calculated kinetic parameters depending upon the mathematical method taken in the analysis.

Analysis of Steady Heat Conduction for Rubber Pads of a Tank Track Subjected to Dynamic Loading (동적하중을 받는 궤도차량 고무패드의 정상 열전도 해석)

  • Kim, Hyung-Je;Kim, Byung-Tak
    • Elastomers and Composites
    • /
    • v.36 no.3
    • /
    • pp.153-161
    • /
    • 2001
  • The rubber pads era tank which undergo dynamic deformations with the sufficient amplitudes and frequencies lead to a considerable internal temperature rise due to the heat generation. The heat generation which is dependent on the viscoelastic characteristics or a rubber is due to the conversion of partial mechanical energy into thermal energy identical to the area oi hysteresis loop. Heat generation without adequate heat dissipation leads to heat build-up and the excessive temperature rite exerts a bad influence upon the performance and the life of rubber products. In this paper, temperature distributions of the rubber pads of a tank track subjected to dynamic loads are obtained under the assumption of the steady state. Heat generation rates used in this finite element analysis are acquired through experiments and the computed temperature fields are displayed in isothermal contour regions.

  • PDF

ASSESSMENT OF CORE BYPASS FLOW IN A PRISMATIC VERY HIGH TEMPERATURE REACTOR BY USING UNIT-CELL EXPERIMENT AND CFD ANALYSIS (단위-셀 실험과 전산유체해석을 통한 블록형 초고온가스로의 노심우회유량 평가)

  • Yoon, S.J.;Jin, C.Y.;Kim, M.H.;Park, G.C.
    • Journal of computational fluids engineering
    • /
    • v.14 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • An accurate prediction of the bypass flow is of great importance in the VHTR core design concerning the fuel thermal margin. Nevertheless, there has not been much effort in evaluating the amount and the distribution of the core bypass flow. In order to evaluate the behavior and the distribution of the coolant flow, a unit-cell experiment was carried out. Unit-cell is the regular triangular section which is formed by connecting the centers of three hexagonal blocks. Various conditions such as the inlet mass flow rate, block combinations and the size of bypass gap were examined in the experiment. CFD analysis was carried out to analyze detailed characteristics of the flow distribution. Commercial CFD code FLUENT 6.3 was validated by comparing with the experimental results. In addition, SST model and standard k-$\varepsilon$ model were validated. The results of CFD simulation show good agreements with the experimental results. SST model shows better agreement than standard k-$\varepsilon$ model. Results showed that block combinations and the size of the bypass gap have an influence on the bypass flow ratio but the inlet mass flow rate does not.

Extraction and Analysis of Dual Gate FET Noise Parameter for High Frequency Modeling (고주파모델링을 위한 이중게이트 FET의 열잡음 파라미터 추출과 분석)

  • Kim, Gue-Chol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.11
    • /
    • pp.1633-1640
    • /
    • 2013
  • In this paper, noise parameters for high frequency modeling of dual-gate FET are extracted and analyzed. To extract thermal noise parameter of dual gate, noise characteristics are measured by changing input impedance of noise source using Tuner, and the influence of pad parasitic elements are subtracted using open and short dummy structure. Measured results indicated that the dual-gate FET is improved the noise figure by 0.2dB compared with conventional cascode structure FET at 5GHz, and it confirmed that the noise figure has dropped due to reduction of capacitances between the drain and source, gate and drain by simulation and analysis of small-signal parameters.

Magnetic Field Distribution Characteristics of Ring-Shaped Electrodeless Fluorescent Lamp (둥근형 무전극 형광램프의 자계 분포 특성)

  • Choi, Yong-Sung;Cho, Jae-Cheol;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.53-57
    • /
    • 2006
  • In this paper, maxwell 3D finite element analysis program (Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 kHz and some specific conditions. The electromagnetic field in the ferrite core was shown to be high and symmetric. An LS-100 luminance meter and a Darsa-2000 spectrum analyzer were used in the experiment. According to data on the lamp tested using high magnetic field ferrite, the optical and thermal wave fields were shown to be high around the ring-shaped electrodeless fluorescent lamp. The optical or light field was high at the center of the bulb rather than around the ferrite core. The light conditions of the bulb were assumed to be complex, depending on the condition of the filler gas, the volume of the bulb, and the frequency of the inverter. Our results have shown coupling between the gas plasma and the field of the light emitted to be nonlinear.

  • PDF

The Effect of EVA Sheet Gel Content on Photovoltaic Modules Durability (EVA Sheet의 Gel Content가 태양전지모듈의 내구성에 미치는 영향)

  • Kang, Gi-Hwan;Park, Chi-Hong;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.20-21
    • /
    • 2006
  • In this paper, we studied the influence of EVA sheet gel content on photovoltaic module durability. Depending on thermal curing temperature and time during lamination, there are dramatic changes on chemical and physical characteristics. To find the optimum PV module process condition, Glass/EVA/Back Sheet scheme was made. Gel Content, FT-IR spectrum and SEM were used for the detail analysis. From these results, $110^{\circ}C/6min$ and $130^{\circ}C/4min$ lamination condition could be suggested for the best one for durable PV module processing. The further analysis is described in the following paper.

  • PDF

A Study of Heat Flux on the Height of an Instantaneous Temperature Probe in a Constant Volume Combustion Chamber (정적 연소기에서 순간온도 프로브의 돌출높이에 따른 열유속에 관한 연구)

  • Lee, C.W.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.4
    • /
    • pp.216-223
    • /
    • 2003
  • In the production of internal combustion engines, there have been trends to develop the high performance engines with improved fuel efficiency, lighter weights and smaller sizes. This trends help to answer problems related to thermal load and abnormal combustion, etc. in these engines. In order to investigate these problems, a thin film-type probe and its manufacturing method for instantaneously measuring surface-temperatures have been proposed in this study, Instantaneous surface temperature of a constant volume combustion chamber was measured by this probe and heat flux was obtained by Fourier analysis. In order to thoroughly understand the characteristics of combustion, the authors measured the wall temperature of the combustion chamber and computed heat flux through a cylinder wall while varying the protrusion height of the probe have been measured. To achieve the above goals, a instantaneous temperature probe was developed, thereby making possible the analysis of the instantaneous temperature of wall surface and the detection of unsteady heat flux in the constant volume combustion chamber.

Application of Water Mist System for a Power Transformer Room -Cooling Characteristics (Part 2) (변압기실 화재에 대한 미분무수 소화시스템의 적용 -냉각특성을 중심으로(Part 2))

  • Choi Byung-Il;Han Yong-Shik;Kim Myung-Bae
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.37-41
    • /
    • 2005
  • The present study describes the cooling performance of two kinds of water mist systems used in fire extinguishment. The cooling is necessary for the prevention of an auto re-ignition of the power transformer. A heat source for such the re-ignition is the accumulated thermal energy in the dielectric oil from the transformer core. Because of the weight of the real core, reduced-scale experiments are carried out. A similarity analysis Is also performed to determine the discharge time of the water mist systems from the experimental results. The discharge time to prevent the re-ignition in the real-scale transformer is estimated about 12 hour from the similarity analysis of the reduced-scale experiments.