• Title/Summary/Keyword: Thermal Scale

Search Result 1,322, Processing Time 0.028 seconds

Development of superconducting high gradient magnetic separation system for scale removal from feed-water in thermal power plant

  • Shibatani, Saori;Nakanishi, Motohiro;Mizuno, Nobumi;Mishima, Fumihito;Akiyama, Yoko;Okada, Hidehiko;Hirota, Noriyuki;Matsuura, Hideki;Maeda, Tatsumi;Shigemoto, Naoya;Nishijima, Shigehiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.18 no.1
    • /
    • pp.19-22
    • /
    • 2016
  • A Superconducting High Gradient Magnetic Separation (HGMS) system is proposed for treatment of feed-water in thermal power plant [1]. This is a method to remove the iron scale from feed-water utilizing magnetic force. One of the issues for practical use of HGMS system is to extend continuous operation period. In this study, we designed the magnetic filters by particle trajectory simulation and HGMS experiments in order to solve this problem. As a result, the quantity of magnetite captured by each filter was equalized and filter blockage was prevented. A design method of the magnetic filter was proposed which is suitable for the long-term continuous scale removal in the feed-water system of the thermal power plant.

Large Scale Treatment of Perfluorocompounds Using a Thermal Plasma Scrubber

  • Han, Sung-Han;Park, Hyun-Woo;Kim, Tae-Hee;Park, Dong-Wha
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.250-258
    • /
    • 2011
  • Thermal plasma has been presented for the decomposition of perfluorocompounds (PFCs) which are extensively used in the semiconductor manufacturing and display industry. We developed pilot-scale equipment to investigate the large scale treatment of PFCs and called it a "thermal plasma scrubber". PFCs such as $CF_4$, $C_2F_6$, $SF_6$, and $NF_3$ used in experiments were diluted with $N_2$. There were two different types of experiment setup related to the water spray direction inside the thermal plasma scrubber. The first type was that the water was sprayed directly into the gas outlet located at the exit of the reaction section. The second type was that the water was sprayed on the wall of the quenching section. More effective decomposition took place when the water was sprayed on the quenching section wall. For $C_2F_6$, $SF_6$, and $NF_3$ the maximum destruction and removal efficiency was nearly 100%, and for $CF_4$ was up to 93%.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Thermal Stability Improvement of Ni-silicide Using Ni-Co alloy for Nano-Scale CMOSFET Technology (나노급 CMOSFET을 윈한 Ni-Co 합금을 이용한 Ni-silicide의 열안정성 개선)

  • Park, Kee-Young;Zhang, Ying-Ying;Jung, Soon-Yen;Li, Shi-Guang;Zhun, Zhong;Lee, Ga-Won;Wang, Jin-Suk;Lee, Hi-Deok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.27-28
    • /
    • 2007
  • In this paper, Ni-Co alloy was used for improvement of thermal stability of Ni silicide. The proposed Ni/Ni-Co structure exhibited wide temperature window of rapid thermal process. Sheet resistance as well as cross-sectional profile showed stable characteristics in spite of high temperature annealing up to $700^{\circ}C$ for 30min. Therefore, the proposed Ni/Ni-Co structure is highly promising for highly thermal immune Ni silicide for nano-scale CMOSFET technology.

  • PDF

Study of Ni-germano Silicide Thermal Stability for Nano-scale CMOS Technology (Nano-scale CMOS를 위한 Ni-germano Silicide의 열 안정성 연구)

  • Huang, Bin-Feng;Oh, Soon-Young;Yun, Jang-Gn;Kim, Yong-Jin;Ji, Hee-Hwan;Kim, Yong-Goo;Wang, Jin-Suk;Lee, Hi-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1149-1155
    • /
    • 2004
  • In this paper, novel methods for improvement of thermal stability of Ni-germano Silicide were proposed for nano CMOS applications. It was shown that there happened agglomeration and abnormal oxidation in case of Ni-germano Silicide using Ni only structure. Therefore, 4 kinds of tri-layer structure, such as, Ti/Ni/TiN, Ni/Ti/TiN, Co/Ni/TiN and Ni/Co/TiN were proposed utilizing Co and Ti interlayer to improve thermal stability of Ni-germano Silicide. Ti/Ni/TiN structure showed the best improvement of thermal stability and suppression of abnormal oxidation although all kinds of structures showed improvement of sheet resistance. That is, Ti/Ni/TiN structure showed only 11 ohm/sq. in spite of 600 $^{\circ}C$, 30 min post silicidation annealing while Ni-only structure show 42 ohm/sq. Therefore, Ti/Ni/TiN structure is highly promising for nano-scale CMOS technology.

Effect of an aspect ratio on thermal stratification in a solar seasonal thermal storage tank (태양열 계간 축열조 내부 열성층화에 대한 탱크 종횡비 영향 연구)

  • Kim, Seong Keun;Jung, Sung Yong
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.2
    • /
    • pp.28-34
    • /
    • 2020
  • In this study, we numerically investigated the thermal stratification in solar seasonal thermal storage tanks. The vertical in/out flows were unsuitable for the thermal stratification in a large scale. The effect of an aspect ratio (AR) on the thermal stratification was investigated. When AR was less than 2, water adheres and flows along the upper wall due to buoyance and the surface effect. Thereafter, hot water flows down and a large scale vortex occurs in entire tank. For high AR, jet flows ejected from the inlet pipe impinges to the opposite wall and splits. The divided flows create two vortex flows in the upper and lower regions. These different flows strongly influence temperature and thermal stratification. The thermal stratification was evaluated in terms of the thermocline thickness and degree of stratification. Compared to ARs, the maximum degree of stratification was obtained with AR of 5 having the minimum thermocline thickness.

Change of thermal environment in buildings by wind direction (풍향에 따른 건물군에서의 열환경 변화)

  • Kim, Sang-Jin
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.27-32
    • /
    • 2012
  • In recent years, the quality of the outdoor thermal environment has come to be regarded as important as that of the indoor thermal environment. Since the outdoor thermal environment is composed of many elements and is affected by many factors, it is not easy to evaluate the impact of each factor separately. Hence, a comprehensive assessment method is required. In order to evaluate the pedestrian level comfort of an outdoor climate, it is necessary to investigate not only wind velocity but also various physical elements, such as temperature, moisture, radiation, etc. Prediction of wind and thermal environment for a large scale buildings is one of the most important targets for research. Wind and thermal change in a city area is a very complicated phenomenon affected by many physical processes. The purpose of this study is to develop a design plan for wind environment at a large Buildings. In this study, we analyze outdoor wind environment and thermal environment on buildings using the CFD (Computational Fluid Dynamics) method. The arrangement of building models is an apartment in Jeonju. These prediction of wind and thermal environment for a large scale buildings is necessary in a plan before a building is built.

Analysis of Positioning Error Factors in the Hydrostatic Tables (유정압테이블의 위치결정오차요인 분석)

  • Oh Y.J.;Park C.H.;Lee D.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.773-776
    • /
    • 2005
  • In this paper, For improving the positioning accuracy of hydrostatic table, relationship between temperature of atmosphere and thermal characteristics of hydrostatic table is analyzed, and influence of thermal characteristics on positioning accuracy is also analyzed experimentally. From the experimental results, it is confirmed that positioning error and repeatability is $0.21{\mu}m\;and\;0.18{\mu}m$ when the laser scale which has $0.01{\mu}m$ of resolution is used as feed-back unit. and also confirmed that thermal deformation of scale and supporter, which occurs by the temperature variation of atmosphere, works as limit of repeatability in long time operation.

  • PDF

Effect of Localized Recrystallization Distribution on Edgebond and Underfilm Applied Wafer-level Chip-scale Package Thermal Cycling Performance

  • Lee, Tae-Kyu
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.1
    • /
    • pp.27-34
    • /
    • 2015
  • The correlation between crack propagation and localized recrystallization are compared in a series of cross section analyses on thermal cycled edgebond and underfilm material applied wafer level chip scale package (WLCSP) components with a baseline of no-material applied WLCSP components. The results show that the crack propagation distribution and recrystallization region correlation can explain potential degradation mechanisms and support the damage accumulation history in a more efficient way. Edgebond material applied components show a shift of damage accumulation to a more localized region, thus potentially accelerated the degradation during thermal cycling. Underfilm material applied components triggered more solder joints for a more wider distribution of damage accumulation resulting in a slightly improved thermal cycling performance compared to no-material applied components. Using an analysis on localized distribution of recrystallized areas inside the solder joint showed potential value as a new analytical approach.