• Title/Summary/Keyword: Thermal Fault

Search Result 205, Processing Time 0.025 seconds

Detection and Diagnosis of Power Distribution Supply Facilities Using Thermal Images (열화상 이미지를 이용한 배전 설비 검출 및 진단)

  • Kim, Joo-Sik;Choi, Kyu-Nam;Lee, Hyung-Geun;Kang, Sung-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Maintenance of power distribution facilities is a significant subject in the power supplies. Fault caused by deterioration in power distribution facilities may damage the entire power distribution system. However, current methods of diagnosing power distribution facilities have been manually diagnosed by the human inspector, resulting in continuous pole accidents. In order to improve the existing diagnostic methods, a thermal image analysis model is proposed in this work. Using a thermal image technique in diagnosis field is emerging in the various engineering field due to its non-contact, safe, and highly reliable energy detection technology. Deep learning object detection algorithms are trained with thermal images of a power distribution facility in order to automatically analyze its irregular energy status, hereby efficiently preventing fault of the system. The detected object is diagnosed through a thermal intensity area analysis. The proposed model in this work resulted 82% of accuracy of detecting an actual distribution system by analyzing more than 16,000 images of its thermal images.

ART2 Neural Network Applications for Diagnosis of Sensor Fault in the Indoor Gas Monitoring System

  • Lee, In-Soo;Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, Duk-Dong;Jeon, Gi-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1727-1731
    • /
    • 2004
  • We propose an ART2 neural network-based fault diagnosis method to diagnose of sensor in the gas monitoring system. In the proposed method, using thermal modulation of operating temperature of sensor, the signal patterns are extracted from the voltage of load resistance. Also, fault classifier by ART2 NN (adaptive resonance theory 2 neural network) with uneven vigilance parameters is used for fault isolation. The performances of the proposed fault diagnosis method are shown by simulation results using real data obtained from the gas monitoring system.

  • PDF

Cooling and Thermal Histories of Cretaceous-Paleogene Granites from Different Fault-bounded Blocks, SE Korean Peninsula: Fission-track Thermochronological Evidences (한반도 동남부의 주단층대에 의해 구분된 지질블록별 백악기-고제3기 화강암의 차별적 냉각-지열 이력: 피션트랙 열연대학적 증거)

  • Shin, Seong-Cheon
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.335-365
    • /
    • 2012
  • Fission-track (FT) thermochronological records from SE Korean Cretaceous-Paleogene granitic plutons in different fault-bounded blocks reveal contrasting cooling and later thermal histories. Overall cooling patterns are represented by a monotonous (J-shaped) curve in most plutons except some Cretaceous granites retaining a complicated (N-shaped) path due to post-reset re-cooling. Discriminative cooling rates over different temperature ranges can be explained for individual plutons with respect to relative pluton sizes, differences in initial heat loss depending on country rocks, and the presence and proximity of later igneous activity. Even within a single batholith, cooling times for different isotherms were roughly contemporaneous with respect to positions. Insignificant deviations in cooling ages from two different plutons in succession across the Yangsan fault may suggest their contemporaneity before major horizontal fault movement. The extent of later thermal rise recorded locally along the Yangsan and Dongnae fault zones were reached the Apatite Partial Stability Zone ($70-125^{\circ}C$), but did not exceed $200^{\circ}C$. Thermal alteration from fractured zones in the Yangsan-Ulsan fault junction may suggest a thermal reset above $290^{\circ}C$ resulting a complete reset in FT sphene age (31 Ma), caused by a tectonic subsidence in Early Oligocene. A consistency in FT zircon/apatite ages (24 Ma) may imply a sudden rapid cooling over $200-105^{\circ}C$, plausibly related to the abrupt tectonic uplift of the Pohang-Gampo Block including the fault junction in Late Oligocene. A remarkable trend of lower cooling ages for $300-200-100^{\circ}C$ isotherms (i.e., 19% for FT sphene and K-Ar biotite; 20% for FT zircon; 27% for FT apatite) from the east of the Ulsan fault (Pohang-Gampo Block) comparing to the west of the fault may be attributed to retarded cooling times from the Paleogene granites and also reflected by their partially-reduced apatite ages due to later thermal effects.

Distribution of geothermal resources of Korea (우리나라의 지열자원 분표)

  • Kim, Hyoung-Chan;Lee, Chul-Woo;Song, Yoonho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.674-677
    • /
    • 2005
  • The characteristics of geothermal resources in Korea was roughly estimated using hot springs, 580 geothermal gradients and 338 heat flow data. In the aspect of hot springs with geologic structure, location of hot springs coincide with fault zone, especially younger age of Cretaceous to Tertiary. In the aspect of geothermal gradients, Pohang area shows the highest geothermal gradient anomaly, which is covered with unconsol idated rock of low thermal conductivity preserving the residual heat from igneous activity or radioactivity elements decay. In the aspect of heat flow density, high anomaly can be found along the zone connecting Uljin-Pohang-Busan on the southeastern part of Korean peninsula at which big fault zone as Yangsan fault is well developed.

  • PDF

A Study on Design, Fabrication Techniques and Test Results of 1.2kV 180A Inductive Superconducting Fault Current Limiter by Conduction-Cooled System (전도냉각에 의한 1.2 KV/80 A급 유도형 고온초전도 한류기의 설계, 제작 및 테스트에 관한 연구)

  • 강형구;전우용;이승제;안민철;배덕권;윤용수;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.30-35
    • /
    • 2003
  • The inductive superconducting fault current limiter (SFCLJ limits the fault current with its dc reactor. To fabricate the optimal dc reactor for inductive SFCL, several design and manufacturing technologies are necessary. In this paper, the manufacturing technology for dc reactor and cryogenic cooling method are described in detail. GM-cryocooler was used enlarge the critical current of dc reactor by cooling down the temperature of dc reactor about 20 K. Moreover, the results of short circuit test were described. Finally, the thermal characteristics of conduction-cooled system were discussed and then, sub-cooled nitrogen system was proposed to enhance the thermal stability of dc reactor.

Variation of Water Content and Thermal Behavior of Talc Upon Grinding: Effect of Repeated Slip on Fault Weakening (활석 분쇄에 따른 함수율 및 열적거동 변화: 단층의 반복되는 미끌림이 단층 약화에 미치는 영향)

  • Kim, Min Sik;Kim, Jin Woo;Kang, Chang Du;So, Byung Dal;Kim, Hyun Na
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.201-211
    • /
    • 2019
  • The particle size and crystallinity of fault gouge generally decreases with slip. Phyllosilicates including talc are known to be present in fault gouge and play an important role in fault weakening. In particular, the coefficient of friction varies depending on the presence of a water molecule on the surface of mineral. The purpose of this study is to investigate the effect of talc on fault weakening by changing the water content and dehydration behavior of talc before and after grinding, which systematically varied particle size and crystallinity using high energy ball mill. Infrared spectroscopy and thermal analysis show that the as-received talc is hydrophobic before grinding and the water molecule is rarely present. After grinding up to 720 minutes, the particle size decreased to around 100 ~300 nm, and in talc, where amorphization proceeded, the water content increased by about 8 wt.% and water molecule would be attached on the surface of talc. As a result, the amount of vaporized water by heating increased after grinding. The dihydroxylation temperature also decreased by ${\sim}750^{\circ}C$ after 720 minutes of grinding at ${\sim}950^{\circ}C$ before grinding due to the decrease of particle size and crystallinity. These results indicate that the hydrophobicity of talc is changed to hydrophilic by grinding, and water molecules attached on the surface, which is thought to lower the coefficient of friction of phyllosilicates. The repeated slip throughout the seismic cycle would consistently lower the coefficient of friction of talc present in fault gouge, which could provide the clue to the weakening of matured fault.

An Experimental Fault Analysis and Speed Control of an Induction Motor using Motor Solver

  • Sengamalai, Usha;Chinnamuthu, Subramani
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.761-768
    • /
    • 2017
  • This paper deals with the performance analysis of three phase induction motor considering its stator side faults and operating thermal limits. The speed control of induction motor using three phase boost converter operated by a MOSFET switch and a PI controller is demonstrated and presented in this article. IGBTs switches are used for inverter drive mechanism. The experimental result of speed control of induction motor using voltage control technique clearly shows better accuracy than conventional methods of speed control. A three phase 1HP 415V 0.78 kW 4 Pole induction motor is designed using motor solver software. Based on the parameters used in the software thermal analysis of induction motor is done and torque variation with conductor area, efficiency, output curve, losses in different parts of motor has been obtained. Also different types of faults namely under voltage, over voltage, stator imbalanced voltage, turn to turn, locked rotor bar, wrong alignment of rotor bar with respect to stator are studied and fault analysis is performed. Hence comparison is made based upon the results obtained before and after faults.

A Study on Thermal Analysis for a Data Center Cooling System under Fault Conditions at a Chilled Water Plant (비상시 열원중단에 따른 데이터센터의 냉각시스템 열성능 평가에 관한 사례연구)

  • Cho, Jinkyun;Kang, Hosuk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.5
    • /
    • pp.178-185
    • /
    • 2016
  • This study describes the analysis of a 20 MW chilled water plant used for the IT cooling of a recently constructed data center in Korea. The CFD model was developed with the aim of evaluating the impact of problems such as chiller failure on the water and air temperatures in the cooling system. The numerical model includes the chilled water hydraulic network and individual water-to-air CRAC units. The coupling between the IT server room air temperature levels and the cooling plant has enabled a full assessment of the cooling system design in response to system fault conditions to be performed. The paper examines an emergency situation involving the failure of the cooling plant, and shows how the inherent thermal inertia of the system along with additional inertia achieved through buffer systems allowed a suitable design to be achieved.

Evaluation on the Properties of the Current Limiting Part for Fault-Current-Limiting Type HTS Cables (사고전류 제한형 고온 초전도케이블의 한류부 특성평가)

  • Kim, Tae-Min;Hong, Gong-Hyun;Han, Byung-Sung;Du, Ho-Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.3
    • /
    • pp.191-195
    • /
    • 2015
  • Inside the existing superconducting cables, the superconducting wire carries a loss-free current, and the cable former (the stranded copper wire) bypasses the fault current to prevent damage and loss of the superconducting cable when the fault current is applied. The fault-current-limiting-type superconducting cable proposed in this paper usually carries a steady current; but in a fault state, the cable generates self-resistance that makes the fault current lower than a certain width. That is, the superconducting cable that transmitted only a low voltage and a large capacity power repetitively limits the fault current, as does a superconducting current limiter. To complete this structure, it is essential to investigate the mutual resistance relationship between the superconducting wires after applying a fault current. Therefore, in this paper, one kinds of superconducting wires (a wire without a stabilization layer) were connected parallel 4 tapes, respectively; and after applying a fault current, the current, voltage, resistance and thermal stability of the HTS thin-film wires were examined.

Switching Characteristics of a Superconducting Current Limiter (초전도전류생성기의 스위칭 특성)

  • 차귀수;한송엽
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.12
    • /
    • pp.1239-1245
    • /
    • 1990
  • With the rapid growth of power system capacity, fault current levels approach the maximum capacity of circuit breakers. In this paper, a superconducting current limiter (SCL) is proposed to reduce the fault current to an appropriate level. Superconductor for SCL has been examined and design criterion of each triggering method has been shown. Thin film SCL has been fabricated and switching characteristics are shown, where thermal and current triggering methods are adopted. Experimental result shows that fault current is reduced to one-half.