• 제목/요약/키워드: Thermal Control System

검색결과 1,275건 처리시간 0.027초

Pl제어 VAV시스템에 대한 공조공간의 열 응답특성 실험 (Experiments on Thermal Response of Space Conditioned by a Pl-Controlled VAV System)

  • 문정우;박강순;김서영
    • 설비공학논문집
    • /
    • 제14권2호
    • /
    • pp.91-97
    • /
    • 2002
  • The present study concerns an experiment on the supply-air control in variable air volume (VAV) system with a Pl control logic. A thermal chamber with a Pl control logic is constructed to verify the previously suggested multi-zone model. The stratified thermal model is adopted in the control logic for a thermal chamber cooling test. The effects of taler- mal parameters and control parameters such as supply air temperature and Pl control factor are investigated by implementing the thermal chamber cooling test. The experimental results obtained show that the transient behavior of the air-conditioned space temperature are in good agreement with the simulation results of the stratified thermal model.

열진공 챔버용 폐회로 열제어시스템 설계 및 성능평가 (Design and Performance Test of a Closed Loop Thermal Control System for Thermal Vacuum Chamber)

  • 서희준;조혁진;박성욱;문귀원;정상헌;허환일
    • 한국항공우주학회지
    • /
    • 제44권1호
    • /
    • pp.88-97
    • /
    • 2016
  • 폐회로 열제어 시스템은 열진공 챔버의 온도를 $-150^{\circ}C{\sim}120^{\circ}C$와 같은 온도 조건으로 모사하기 위한 시스템으로, 극저온 블로워, 슈라우드, 히터, 극저온 밸브 등으로 구성된다. 본 연구는 우주 열환경 모사를 위한 폐회로 열제어 시스템의 설계 요소 정의 및 제어 변수별 실험 결과 등을 포함하고 있다. 폐회로 열제어 시스템 설계를 위해 설계 요소인 블로워 용량, 슈라우드 재질, 형태에 따른 특성 등의 분석을 수행 하였다. 폐회로 열제어 시스템의 극저온 블로워 필요 유량은 에너지 평형 방정식에 의해 결정되며, 제어는 작동 유체의 밀도 제어를 통해 제어된다. 밀도, 회전수와 같은 제어 변수별 실험을 통해 슈라우드 온도 분포 균질도 및 균일도를 측정하여 요구된 폐회로 열제어 시스템의 성능을 확인 하였다.

태양광 발전의 성능향상을 위한 PV/T 시스템 개발 (Development of PV/T for Performance Improvement of Photovoltaic System)

  • 최정식;고재섭;강성준;백정우;장미금;문주희;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.95-96
    • /
    • 2010
  • This paper proposes photovoltaic thermal hybrid module to get the electrical and Thermal performance of building integrated photovoltaic(BIPV) system. BIPV system is decreased the system efficiency because output of PV is decreased by the thermal rising on generating. In order to improve the efficiency of BIPV module, water cooling system is applied and generated thermal is used the warm water system. Water cooling system uses the flux control algorithm considering water temperature and power loss. Electrical and thermal performance of proposed photovoltaic thermal hybrid module is confirmed through the actual experiment and herby proved the valid of this paper.

  • PDF

Heliostat 제어시스템 (Heliostat Control System)

  • 박영칠
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.50-57
    • /
    • 2009
  • Heliostat in the tower type solar thermal power plant is a mirror system tracking the sun's movement to collect the solar energy and it is the most important subsystem determining the efficiency of solar thermal power plant. Thus a good performance of it, which is mostly the accurate sun tracking performance under the various hazardous operating condition, is required. Heliostat control system is a system to manage the heliostat sun tracking movement and other operations. It also communicates with the master controller through the heliostat filed control system to receive and send the informations required to operate the heliostat as a part of the solar thermal power plant. This study presents a heliostat control system designed and developed for the 1MW solar thermal power plant. We first define the functionality of heliostat control system. Then sun tracking controller as well as the sun tracking algorithm satisfying the required functionality have been developed. We tested the developed heliostat control system and it showed a good performance in regulation of heliostat motion and communication.

유전자(DNA)증폭 온도 사이클 시스템에 열전소자 활용을 위한 연구 (Application of thermoelectric module to DNA amplifying thermal cycle system)

  • 조재설;정세훈;남재영;최재붕;김영진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.210-215
    • /
    • 2004
  • : A DNA analysis system based on fluorescence analysis has to have a DNA amplifying thermal cycle system. DNA amplification is executed by the temperature control. Accuracy of fluorescence analysis is influenced by the temperature control technology. For that reason, the temperature control is core technology in developing the DNA analysis system. Therefore, the objective of this paper is to develop the hardware to apply thermoelectric module to the DNA amplifying thermal cycle system. In order to verify the developed hardware for controlling the temperature of thermoelectric module, a DNA amplifying thermal cycle test was performed. From the test, the developed hardware controlled the temperature of thermoelectric module successfully. Therefore, it is expected that the developed hardware can be applied to the DNA amplifying thermal cycle system.

  • PDF

부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석 (A Performance Analysis on a Heat pump with Thermal Storage Adopting Load Response Control Method)

  • 김동준;강병하;장영수
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.130-142
    • /
    • 2018
  • We use heat pumps with thermal storage system to reduce peak usage of electric power during winters and summers. A heat pump stores thermal energy in a thermal storage tank during the night, to meet load requirements during the day. This system stabilizes the supply and demand of electric power; moreover by utilizing the inexpensive midnight electric power, thus making it cost effective. In this study, we propose a system wherein the thermal storage tank and heat pump are modeled using the TRNSYS, whereas the control simulations are performed by (i) conventional control methods (i.e., thermal storage priority method and heat pump priority method); (ii) region control method, which operates at the optimal part load ratio of the heat pump; (iii) load response control method, which minimizes operating cost responding to load; and (iv) dynamic programming method, which runs the system by following the minimum cost path. We observed that the electricity cost using the region control method, load response control approach, and dynamic programing method was lower compared to using conventional control techniques. According to the annual simulation results, the electricity cost utilizing the load response control method is 43% and 4.4% lower than those obtained by the conventional techniques. We can note that the result related to the power cost was similar to that obtained by the dynamic programming method based on the load prediction. We can, therefore, conclude that the load response control method turned out to be more advantageous when compared to the conventional techniques regarding power consumption and electricity costs.

구배법 알고리즘에 의한 슬래브축열의 최적제어 해석 (An Analysis of the Optimal Control of Air-Conditioning System with Slab Thermal Storage by the Gradient Method Algorithm)

  • 정재훈
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.534-540
    • /
    • 2008
  • In this paper, the optimal bang-bang control problem of an air-conditioning system with slab thermal storage was formulated by gradient method. Furthermore, the numeric solution obtained by gradient method algorithm was compared with the analytic solution obtained on the basis of maximum principle. The control variable is changed uncontinuously at the start time of thermal storage operation in an analytic solution. On the other hand, it is showed as a continuous solution in a numeric solution. The numeric solution reproduces the analytic solution when a tolerance for convergence is applied severely. It is conceivable that gradient method is effective in the analysis of the optimal bang-bang control of the large-scale system like an air-conditioning system with slab thermal storage.

Retrofit of Analog Boiler Control Systems with Digital Control Systems in a Thermal Power Plant

  • Park, Doo-Yong;Byun, Seung-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1304-1308
    • /
    • 2005
  • This paper presents the case that the existing analog control systems were retrofitted with digital DCS(Distributed Control System)s for boiler unit in thermal power plant. Replacement of existing worn-out or obsolete analog control systems has been considered. Replacement of existing analog control systems with another analog control systems has lots of difficulties in maintaining the systems due to being out of stock. Due to those difficulties, existing analog control systems have been retrofitted with digital DCSs in many industrial sites. KEPRI(Korea Electric Power Research Institute) accomplished the project that retrofitted analog control systems with the developed DCSs for boiler unit in middle-scale coal-fired thermal power plant. The benefits of an upgrade to digital control include a increase of reliability due to system redundancy, ease of modifying the control logic and the parameters of function block, ease of maintenance due to available spare parts, improvement of information display, ease of modifying MMI(Man Machine Interface) displays, a increase in system availability, and improvement of control performance. This paper describes how to use the parameters of existing analog controllers, the implementation of digital PID controller, control system configuration for boiler unit in thermal power plant, some boiler control loops, control result during commissioning, and the comparison of boiler characteristic test data after retrofitting with the existing test data.

  • PDF

바닥복사난방의 실별제어시스템에 관한 열성능 평가 (An Evaluation on the Thermal Performance of the Room Control System for Radiant Floor Heating)

  • 석호태;김오봉;조영흠;김광우;여명석
    • 한국주거학회논문집
    • /
    • 제14권5호
    • /
    • pp.75-82
    • /
    • 2003
  • In this study, the thermal performance of the room control system is analyzed in terms of control performance, potential for coil expansion and energy consumption through experiments comparing the individual room control system and an existing system. The results of this study show that the existing system is not able to supply design water flow rate and does not accurately maintain the set point temperature in each room. However, the individual room control system can set a room air temperature for each room, for it is able to supply design water flow and accurately control the set point temperature in each room and can reduce the energy consumption compared to the existing system. Moreover, the individual room control system can reduce the number of coil division zone and facilitates the construction process, because it can extend the length of the coil division.

초점면 배열 방식의 열상카메라 시스템의 구현 (Implementation of a Thermal Imaging System with Focal Plane Array Typed Sensor)

  • 박세화;원동혁;오세중;윤대섭
    • 제어로봇시스템학회논문지
    • /
    • 제6권5호
    • /
    • pp.396-403
    • /
    • 2000
  • A thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main part of the system is a thermal camera in which a focal plane array typed sensor is introduced. The sensor detects the mid-range infrared spectrum of target objects and then it outputs a generic video signal which should be processed to form a frame thermal image. Here, a digital signal processor(DSP) is applied for the high speed processing of the sensor signals. The DSP controls analog-to-digital converter, performs correction algorithms and outputs the frame thermal data to frame buffers. With the frame buffers can be generated a NTSC signal and transferred the frame data to personal computer(PC) for the analysis and a monitoring of the thermal scenes. By performing the signal processing functions in the DSP the overall system achieves a simple configuration. Several experimental results indicate the performance of the overall system.

  • PDF