• Title/Summary/Keyword: Therm

Search Result 57, Processing Time 0.033 seconds

Results of Intradiscal Pulsed Radiofrequency for Lumbar Discogenic Pain: Comparison with Intradiscal Electrothermal Therapy

  • Fukui, Sei;Nitta, Kazuhito;Iwashita, Narihito;Tomie, Hisashi;Nosaka, Shuichi;Rohof, Olav
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.155-160
    • /
    • 2012
  • Background: We have developed an intradiscal pulsed radiofrequency (Disc PRF) technique, using Diskit $II^{(R)}$ needles (NeuroTherm, Wilmington, MA, USA), as a minimally invasive treatment option for chronic discogenic low back pain (LBP). The purpose of this study was to compare the representative outcomes of Disc PRF and Intradiscal Electrothermal Therapy (IDET) in terms of pain relief and reduction of disability. Methods: Thirty-one patients with chronic discogenic LBP who underwent either Disc PRF (n = 15) or IDET (n = 16) were enrolled in the study. A Diskit $II^{(R)}$ needle (15-cm length, 20-gauge needle with a 20-mm active tip) was placed centrally in the disc. PRF was applied for 15 min at a setting of $5{\times}50$ ms/s and 60 V. The pain intensity score on a 0-10 numeric rating scale (NRS) and the Roland-Morris Disability Questionnaire (RMDQ) were assessed pretreatment and at 1, 3, and 6 months post-treatment. Results: The mean NRS was significantly improved from $7.2{\pm}0.6$ pretreatment to$2.5{\pm}0.9$ in the Disc PRF group, and from $7.5{\pm}1.0$ to $1.7{\pm}1.5$ in the IDET group, at the 6-month follow-up. The mean RMDQ also showed significant improvement in both the Disc PRF group and the IDET group at the 6-month follow-up. There were no significant differences in the pretreatment NRS and RMDQ scores between the groups. Conclusions: Disc PRF appears to be an alternative to IDET as a safe, minimally invasive treatment option for patients with chronic discogenic LBP.

Mechanical Stability Analysis of a High-Level Waste Repository for Determining Optimum Cavern and Deposition Hole Spacing (고준위폐기물 처분장의 최적 공동간격 및 처분공간격을 결정하기 위한 역학적 안정성 해석)

  • 박병윤;권상기
    • Tunnel and Underground Space
    • /
    • v.10 no.2
    • /
    • pp.237-248
    • /
    • 2000
  • Based on the preliminary results from the therm analysis, which is currently carrying, three-dimensional computer simulations using a finite element code, ABAQUS Ver. 5.8, were designed to determine the mechanically stable cavern and deposition hole spacing. Linear elastic modeling for the cases with different cavern and deposition hole spacing were carried out under three different in situ stress conditions. From the simulations, the response of the rock to the stress redistribution after the excavation of the openings could be investigated. Also the optimum cavern and deposition hole spacing could be estimated based on the factor of safety. When the in situ stress determined from the actual stress measurements in Korea were used, the case with cavern spacing of 40m and deposition hole spacing of 3m was in very stable condition, because the factor of safety was calculated as 3.42., When the in situ stress conditions for Sweden and Canada were used, the previous case, they seem to be in stable condition, since the factors of safety are still higher than 1.0. From these results, it was concluded that the rock will not fail even after the stress redistribution.

  • PDF

Die stress and Process of Analysis for Condenser Tube Extrusion by using a Porthole Die (포트홀 다이를 이용한 컨덴서 튜브 직접압출 공정해석 및 금형강도 해석)

  • Lee, J. M.;lee, S. K.;Kim, B. M.;Jo, H. H.;Jo, H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1030-1033
    • /
    • 2002
  • In this study, it is important that we have an understanding of the metal flow for manufacturing condenser tube in porthole die extrusion, because this need to provide for household appliances market that is expected to grow into the major market of the cooling system hereafter. Condenser tube is mainly manufactured by conform exclusion. However, this method was not satisfied a series of the needs for manufacturing condenser tube as compared with porthole die extrusion. The deforming skill recently is required high-productivity, high-accuracy and reducing lead-time, thus it is essential to substitute conform exclusion by porthole die exclusion. Porthole die extrusion has many advantages such as improvement of productivity, reduction of production cost etc. In general, the porthole die extrusion process consists of three stages(dividing, welding and forming stages). In order to obtain the detailed mechanics, to assist in the design of proper die shapes and sizes, and to improve the quality of products, porthole die extrusion should be analyzed in as non-steady state as possible during the entire process to evaluate detailed metal flow, temperature distribution, welding pressure and extrusion lead, and therm stress analysis was practiced to obtain effective stress and elastic deformation value. A analytical results provide useful information the optimal design of the porthole die for condenser tube.

  • PDF

A study on the Optimum Design Configuration of Passive Solar TI-wall system (투명단열재가 적용된 축열벽 시스템의 최적구성 선정에 관한 연구)

  • Kim, Byoung-Soo;Yoon, Jong-Ho;Yoon, Yong-Jin;Baek, Nam-Choon
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.37-44
    • /
    • 2003
  • The aim of this study was to analyze the thermal performance through Test-Cell of TI-wall in domestic climate. This study was carried out as follows: 1) The TI-wall was studied for ability to reduce heat loss through the building envelope and analyzed to TIM properties. 2) Test models of TI-wall were designed through the investigation of previous paper and work, measured for winter and spring, and the thermal effects were analyzed. The type of the TIM used in test model is small-celled(diameter 4mm and thickness 50mm) capillary and cement brick(density $1500kg/m^3$) was used by thermal mass. 3) Test-cell of TI-wall was calibrated from measured data and the dynamic simulation program ESP-r 9.0. In these simulations, the measured climate conditions of TaeJon were used as outdoor conditions, and the simulation model of Test-cell was developed. 4) The sensitivity analysis is executed in various aspects with standard weather files and ESP-r 9.0, and then most suitable system of TI-wall are predicted. Finally, The suitable system of TI-wall was analysed according to sizes of air gap, kinds, thickness, and the surface absorption of therm wall. The result is following. In TI-wall, Concrete is better than cement brick, at that time the surface absorption is 95%, and the most efficient thickness is 250mm. As smaller of a air gap, as reducer of convection heat loss, it is efficient for heating energy. However, ensuring of a air gap at least more than 50mm is desirable for natural ventilation in Summer.

Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea (창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가)

  • Lim, Hee Won;Kim, Dong Yun;Lee, Soo Man;An, Jung Hyuk;Yoon, Jong Ho;Shin, U Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

A comparative analysis of the simulation results of total window thermal transmittance(Uw) according to the evaluation method - Focused on comparison of the single window simulation results - (창세트 전체 열관류율(Uw) 평가 방법에 따른 시뮬레이션 결과 비교 분석 - 단창 창세트에 대한 시뮬레이션 결과 비교를 중심으로 -)

  • Lee, Yong-jun;Oh, Eun-joo;Kim, Sa-kyum;Choi, Hyun-jung;Kim, Yu-min
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The aim of this study is to calculate U-factor of the window using international standard methods and compare quantitative and tendency difference focused on ISO standard 15099 and ISO standard 10077. And the result of ISO standard calculation methods is verified using thermal performance experiment to evaluate applicability of domestic certification system. This study is utilized a basis for activation of domestic window certification system. Method: First, 16 cases are selected that is combined a variety of frame, Glazing, spacer, etc. The selected cases were simulated using WINDOW&THERM based on ISO 15099 and 10077 calculation method. Second, experiment was conducted based on Korean standard condition. Then, it was compared the error of experiment and simulation results. Through this process, ISO 15099 and 10077 calculation methods were evaluated accuracy and utilization. Result: The results show that the difference of ISO 15099 and ISO 10077-2 is maximum 5.4%. The results of comparing U-factor errors based on the Korea standard experiment test found 2.4%. Consequently, it will be possible to combination calculation methods of ISO 15099 and ISO 10077 for a single window.

Influence of Various Types of Exercise on Bone Formation and Resorption in Rats (운동 형태가 흰쥐의 뼈형성에 미치는 영향)

  • 홍희옥;이준혜;정동춘;소재무;나까또미료이찌;최의창;황금희;안의환;맹원재
    • Journal of Nutrition and Health
    • /
    • v.34 no.5
    • /
    • pp.541-546
    • /
    • 2001
  • This study examined the effect of various types of exercise on bone formation and resorption in rat. Five-week-old male Sprague-Daweley rats were randomly assigned to one of four groups with 10 animals in each; Control, Treadmill, Swimming, Resistance. The exercise regimen consisted of treadmill running at 25m/min, 1 hr per day, 5 days a week, and swimming for 1 hr per day, 5 days a week. Resistant exercise type with weight-bearing was designed to extend lower and upper extremities in order to feed the diet and water. Food intake showed no significant difference among groups but body weight gain and food efficiency were significantly increased in Control group as compared with exercise groups. Femur and tibia length and weight were higher in Control group and the density of therm tended to be higher in exercise groups than Control group, but this difference was not statistically significant. The breaking force of femur was the highest in Swimming group and tibia was the highest in Resistance group among groups, while there was no signigicant difference among the exercise groups. The calcium content of femur was significantly increased in Resistance group than the other groups. Calcium intake and urinary calcium showed no significant difference among groups, while calcium absorption and retention were significantly higher in exercise group than Control group. In conclusion, exercise training enhanced bone formation due to the positive effect on metabolism of calcium and bone which were different according to the types of exercise. (Korean J Nutrition 34(5) : 541∼546, 2001)

  • PDF

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

A Study on the Thermal Bridge Reduced Stiffeners for the Reduction of Window Overall Hear Transfer Coefficient (창문 열관류율 저감을 위한 열교 저감형 보강재 연구)

  • Jang, Hyok-Soo;Kim, Young-Il;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.71-80
    • /
    • 2015
  • Steel stiffener is required for reinforcing the structure of the window frame made of versatile but weak PVC material. Steel stiffener however becomes a source of greater heat loss and frequently plays a role of thermal bridge due to its high thermal conductivity. To maintain thermal resistance similar to PVC frame, steel stiffener is perforated to reduce the effective heat transfer area. To compensate the structural strength of the steel stiffener which is weakened by the perforation, the thickness is increased. Increase in thickness will also increase the thermal heat resistance. Five samples which are PVC frame, PVC frame + original steel stiffener, PVC frame + 30% perforated steel stiffener, PVC frame + 50% perforated steel stiffener, PVC frame + 65% perforated steel stiffener are modeled and simulated for 2nd moment of area and thermal resistance. Therm/window version 6.3 is used for thermal analysis. The results show that among the five samples analyzed, PVC frame + 65% perforated steel stiffener best satisfies both structural strength and thermal resistance.

The effect of market attributes on Long-term Care(LTC) Service

  • Jeon, Gwon-Cheol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.8
    • /
    • pp.119-128
    • /
    • 2020
  • In this research, a survey was done on two hundred and forty-six elders who receive care through LTC to verify the effect of market attributes on the user satisfaction of the Long-therm Care Service. The collected data were analyzed through SPSS 23.0 statistics program. This study reveals the following results: First, in service tangibility, competitiveness, administrative regulation, organizational process, and autonomy in choice all have a positive relation with user satisfaction. Second, in the aspect of credibility, house ownership, competitiveness, administrative regulation, and freedom in choice show a positive-relation with user satisfaction. Third, in responsiveness, the scale of the organization, monthly income, competitiveness, administrative regulation, organizational process, and autonomy in choice have a positive effect on user satisfaction. Forth, in assurance ability, monthly income, competitiveness, administrative regulation, organizational process, and autonomy in choice also positively affected user satisfaction. Lastly, in the aspect of perceptual openness, competitiveness, administrative regulation, organizational culture, organizational process, and autonomy in choice show a positive relationship with user satisfaction.