• Title/Summary/Keyword: The single transformer

Search Result 380, Processing Time 0.033 seconds

Power Decoupled Multi-Port Dual-Active-Bridge Converter Employing Multiple Transformers for DC Distribution Applications (복수의 변압기를 사용하여 독립 전력제어가 가능한 DC 배전용 다중포트 Dual-Active-Bridge 컨버터)

  • Kim, Inhyeok;Sim, Ju-Young;Lee, Jun-Young;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.4
    • /
    • pp.286-292
    • /
    • 2020
  • This study proposes a power decoupled multi-port dual-active-bridge (DAB) DC-DC converter employing multiple transformers. Conventional multiport DAB DC-DC converters experience a power coupling issue from the use of a single transformer, which essentially requires complex power decoupling control. To solve this issue, a multiport DAB DC-DC converter employing multiple transformers is proposed to decouple output power without additional complex control algorithms. The proposed converter uses multiple transformers that can expand output ports easily. Therefore, transformers and the proposed multi-port DAB converter can be designed simply. In addition, the number of coupling inductors can be reduced in the proposed three-port DAB converter compared with that in conventional multiport DAB converters. The power decoupling characteristics and equivalent circuit of the proposed converter are analyzed using theoretical model approaches. Finally, a 3-kW laboratory prototype is developed to verify the effectiveness of the proposed converter.

Electronic Ballast using Current-Fed Push-Pull Resonant Inverter with Single-Stage Power Factor Correction Circuit (전류원 방식 푸시-풀 공진형 인버터로 구성된 단일단 고역률 형광등용 전자식 안정기)

  • Chae, Gyun;Ryoo, Tae-Ha;Cho, Gyu-Hyeong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.5
    • /
    • pp.501-507
    • /
    • 2000
  • A nobel low-cost, simple and unity-power-factor electronic ballast is presented. The proposed electronic ballast employs a bypassing capacitor- and load networks composed of ballast capacitors and small charge pump capacitors as power factor correction circuit combined with the secondary winding of the transformer in the self-excited current-fed push-pull resonant inverter(CF-PPRI), resulting in cost-effectiveness and higher efficiency. By analyzing the princip1es of power factor correction mathematically, optimum design guidelines are presented. Since the lamps are used in power factor correction stage, the input power is automatically adjusted according to the number of the lamps.

  • PDF

A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident (결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구)

  • Kwak, Dong-Kurl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

A Three Phase Three-level PWM Switched Voltage Source Inverter with Zero Neutral Point Potential

  • Oh Won-Sik;Han Sang-Kyoo;Choi Seong-Wook;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.5 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • A new three phase three-level Pulse Width Modulation (PWM) Switched Voltage Source (SVS) inverter with zero neutral point potential is proposed. It consists of three single-phase inverter modules. Each module is composed of a switched voltage source and inverter switches. The major advantage is that the peak value of the phase output voltage is twice as high as that of a conventional neutral-point-clamped (NPC) PWM inverter. Thus, the proposed inverter is suitable for applications with low voltage sources such as batteries, fuel cells, or solar cells. Furthermore, three-level waveforms of the proposed inverter can be achieved without the switch voltage imbalance problem. Since the average neutral point potential of the proposed inverter is zero, a common ground between the input stage and the output stage is possible. Therefore, it can be applied to a transformer-less Power Conditioning System (PCS). The proposed inverter is verified by a PSpice simulation and experimental results based on a laboratory prototype.

Design of fuel cell power conversion system controlled by TMS32OC31 DSP Chip (TMS32OC31 DSP칩에 의해 제어되는 연료전지용 전력변환장치의 설계)

  • Mun, S.P.;Kwon, S.K.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.351-354
    • /
    • 2006
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system It needs both a DC-DC step-up converter and DC-AC inverter to be used in fuel cell generation system Therefor, this paper, consists of an isolated DC -DC converter to boost the fuel cell voltage 380[$V_{DC}$] and a PWM inverter with LC filter to convent the DC voltage to single phase 220[$V_{AC}$]. Expressly, a tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed high frequency isolated ZVZCS PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena Besides the efficiency of 93-97[%]is obtained over the wide output voltage regulation ranges and load variations.

  • PDF

Numerical Analysis and Measurement of Magnetization Loss in BSCCO Multi-stacked Conductor According to Stacking Geometry (적층 배열형상에 따른 BSCCO 적층선재의 자화손실 특성 수치해석 및 측정)

  • Park, Myung-Jin;Lim, Hyoung-Woo;Lee, Kwang-Youn;Cha, Guee-Soo;Lee, Ji-Kwang
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.83-88
    • /
    • 2006
  • AC loss is one of the main research area in AC power application using high temperature superconductor(HTS), such as HTS transformer, HTS current limiter and HTS cable, because it is closely related to efficiency, economic estimation and design of power device. A lot of research for various arrangements of HTS tapes have been performed to increase a capacity of transport current because single HTS tape can not satisfy the demanded current capacity in HTS power application. In this paper, we studied magnetization loss by different several arrangements of BSCCO tapes such as Edge-to-Edge type, Face-to-Face type and Matrix type through numerical analysis by 2D-FEM and measurement. As a result, we got the result that the magnetization loss of Face-to-Face type arrangements was lower than those of other arrangement types under the conditions of the same stacking number. We think that the result was due to shield effect by demagnetization of adjacent HTS tapes which are located face to face.

Development of 3.0[kW] class Fuel Cell Power Conversion System(I) (3[kW]급 연료전지용 전력변환장치(I)의 개발)

  • Mun, S.P.;Kwon, S.K.;Suh, K.Y.;Kim, Y.M.;Ryu, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1207-1208
    • /
    • 2006
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system. It needs both a DC-DC step-up converter and DC-AC inverter to be used in fuel cell generation system. Therefor, this paper, consists of an isolated DC-DC converter to boost the fuel cell voltage 380[VDC] and a PWM inverter with LC filter to convent the DC voltage to single-phase 220[VAC]. Expressly, a tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed high frequency isolated ZVZCS PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of 93-97[%] is obtained over the wide output voltage regulation ranges and load variations.

  • PDF

Analysis and Design of Coupled Inductors for Two-Phase Interleaved DC-DC Converters

  • Lee, Jong-Pil;Cha, Honnyong;Shin, Dongsul;Lee, Kyoung-Jun;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.339-348
    • /
    • 2013
  • Multiphase dc-dc converters are widely used in modern power electronics applications due to their advantages over single-phase converters. Such advantages include reduced current stress in both the switching devices and passive elements, reduced output current ripple, and so on. Although the output current ripple of a converter can be significantly reduced by virtue of the interleaving effect, the inductor current ripple cannot be reduced even with the interleaving PWM method. One way to solve this problem is to use a coupled inductor. However, care must be taken in designing the coupled inductor to maximize its performances. In this paper, a detailed analysis of a coupled inductor is conducted and the effect of a coupled inductor on current ripple reduction is investigated extensively. From this analysis, a UU core based coupled inductor structure is proposed to maximize the performance of the coupled inductor.

BESS Application to Voltage Compensation of AC Railway System based on 3ϕ/1ϕ BTB Voltage Source Converter (3상/단상 BTB 전압형 컨버터 기반의 전기철도 급전 시스템의 전압제어 향상을 위한 BESS 적용)

  • Yoo, Hyeong-Jun;Shin, Seungkwon;Jung, Hosung;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1588-1593
    • /
    • 2014
  • The scott transformer changes three-phase power to two single-phase power. However, this method causes unbalance and fluctuation of voltage by the change of electric railload. Recently, the AC railway system based on $3{\Phi}/1{\Phi}$ back-to-back (BTB) voltage source converter (VSC) has been proposed to solve these problems. Meanwhile, battery energy storage system (BESS) is used to compensate voltage instantaneously in power system. In this paper, BESS application to the AC railway system based on $3{\Phi}/1{\Phi}$ BTB VSC is suggested to compensate voltage instantaneously. The application effect is shown through simulation using MATLAB/SIMULINK.

Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings (사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석)

  • Yoo, Jae-Geun;Lee, Sang-lck;Jeon, Jeong-Chay;Jeong, Jong-Wook;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.155-161
    • /
    • 2005
  • Nonlinear electronic loads used at office buildings distort the voltage and current waveform that cause the overheating of transformer losses, ELB(Electrical Leakage Breaker) tripping, and so on. This paper analyzed waveform distortion characteristics at several once buildings by comparing with magnitude of voltage and current harmonics, crest factor of voltage and current, phase voltage and current unbalance. As a consequence, severe current waveform distortion in phase and neutral line by harmonics and high current unbalance rates by unbalanced using of single loads among the three phases are investigated. The results of the study can be used in making decisions regarding reasonable and economical operating of loads at office buildings.