• Title/Summary/Keyword: The pulse

Search Result 10,382, Processing Time 0.033 seconds

A Peaking Switch to Generate a High Voltage Pulse of Sub-nanosecond Rise Time (서브 나노초 상승시간의 고전압 펄스 발생용 피킹 스위치)

  • Roh, Young-Su;Jin, Yun-Sik;Cho, Chu-Hyun;Lim, Soo-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1300-1305
    • /
    • 2012
  • A triaxial Blumlein pulse forming line has been designed to generate a pulse whose voltage is ~300 kV, pulse duration is ~5 ns, and rise time is ~500 ps. It turns out, however, that the rise time of the pulse becomes much longer than 500 ps due to parasitic inductances and capacitances existing inside the system. A peaking switch has been developed to shorten the rise time of the pulse from Blumlein pulse forming line. In the peaking switch, a wedge-shaped dielectric material (MC 901 nylon) is employed to surround the electrode on the antenna side. This shape inhibits an abrupt change of the output impedance, thereby minimizing the reflection of the output pulse. Experimental results show that the peaking switch is capable of improving the rise time of the pulse at a level of 500 ps.

The Development of pulse Diagnostic Apparatus enable to gain multi-information and it's Clinical Significance (다정보(多情報) 획득(獲得)을 위한 맥진기 개발과 임상적 의의)

  • Park, Y.B.;Lee, H.J.;Huh, W
    • The Journal of Korean Medicine
    • /
    • v.16 no.1 s.29
    • /
    • pp.499-504
    • /
    • 1995
  • Recently, there are deep and much concerns about the objective assessment of diagnosis in Oriental Medicine. Among them, pulse diagnostics is used for the quantitative device of diagnosis. The objective research of pulse diagnosis were mainly conducted by pulse wave. So it is important to gain multi-information for the quantification of pulse diagnosis. We report the development of pulse diagnostic apparatus enable to gain the multi-information, detect the pressure pulse wave in conku(寸口) area and obtain the gradient curve and original pulse wave simultaneously, and consider the pulse wave with the traditional pulse diagnosis at the same time.

  • PDF

Significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'The affected part of the pulse wave' ('맥상(脈狀)의 환측(患側)' 취혈(取穴)과 침(鍼) 치료(治療) 경과 확인 기준으로서의 촌구맥진(寸口脈診)의 의의(意義))

  • Sim, So-Hyun;Kang, Min-Jung;Kim, Jae-Kyu;Baek, Jin-Ung
    • Journal of Korean Medical classics
    • /
    • v.27 no.1
    • /
    • pp.47-56
    • /
    • 2014
  • Objective : The aim of this study is to find out the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' based on the literature. Method : (1) The clear concepts of the 'unaffected part' and the 'affected part' were organized. (2) The relation between the pulse diagnosis and the acupuncture in Hwangjenaekyung was studied. (3) The indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) in Hwangjenaekyung was studied. (4) The types and changes of pulse diagnosis in Hwangjenaekyung was studied, especially based on the relation between Sambuguhu pulse diagnosis(三部九候脈診) and Chongu pulse diagnosis(寸口脈診). (5) By synthesizing these results, the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' was found. Result & Conclusion : 1. When the affected part and the unaffected part are defined, it is necessary to make clear that which one of next three definitions is used ; Firstly, 'the broad sense of definition of the affected part and the unaffected part of the symptom', which contains the pulse wave. Secondly, 'the narrow sense of definition of the affected part and the unaffected part of the symptom', without the pulse wave. And thirdly, 'the definition of the affected and the unaffected part of the pulse wave', which has the only independent standard of the pulse wave. 2. Geo acupuncture treatment(巨刺法) is an acupuncture treatment which means the needling on 'the affected part of the pulse wave' based on Sambuguhu pulse diagnosis (三部九候脈診), and Mu acupuncture treatment(繆刺法) is an acupuncture treatment which means the needling on 'the unaffected part of the symptom based on the narrow sense of the definition'. The range of the indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) contains most of the diseases which contains Rakbyung(絡病), Kyungbyung(經病) and Ojangbyung(五臟病). 3. Chongu pulse diagnosis(寸口脈診) contains not only the range of the indications of Sambuguhu pulse diagnosis(三部九候脈診), but also most of the diseases. 4. From synthesizing these results of the study on the literature, we infer that Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' is significant.

A Study on Destruction Characteristics of BJT (Bipolar Junction Transistor) at Different Pulse Repetition Rate (다양한 펄스 반복률에서의 NPN BJT (Bipolar Junction Transistor)의 파괴 특성에 관한 연구)

  • Bang, Jeong-Ju;Huh, Chang-Su;Lee, Jong-Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • This paper examines the destruction behavior of NPN BJT (bipolar junction transistor) by repetition pulse. The injected pulse has a rise time of 1 ns and the maximum peak voltage of 2 kV. Pulse was injected into the base of transistor. Transistor was destroyed, current flows even when the base power is turned off. Cause the destruction of the transistor is damaged by heat. Breakdown voltage of the transistor is 975 V at single pulse, and repetition pulse is 525~575 V. Pulse repetition rate increases, the DT (destruction threshold) is reduced. Pulse Repetition rate is high, level of transistor destruction is more serious.

Frequency-Modulated Pulse-Amplification Method for Reducing Pulse Shape Distortion

  • Jeong, Jihoon;Cho, Seryeyohan;Hwang, Seungjin;Yu, Tae Jun
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1637-1643
    • /
    • 2018
  • To reduce the laser pulse shape distortion accompanying the amplification process and achieve an intended output pulse shape in the Nd:YAG amplifier chain, we propose a frequency-modulated pulse-amplification method. Assuming carrier-frequency-modulated seed pulses, we numerically simulate the pulse amplification in an Nd:YAG amplifier chain where severe distortion occurs. For the calculation, we develop a modified Frantz-Nodvik equation, which enables two inputs with different carrier frequencies. The simulation results indicate that the temporal contrast of the seed pulse needed to obtain a flat output pulse shape is reduced by 16 - 25 dB when frequency modulation is applied.

Suggestion for Objective Evaluation of Comparative Pulse Diagnosis

  • Jun-Sang Yu
    • Journal of Pharmacopuncture
    • /
    • v.27 no.1
    • /
    • pp.21-26
    • /
    • 2024
  • Objectives: Pulse is a method of Korean medicine diagnosis and is an important clue to detect the organs, nature, and progress of the disease. Pulse examination is included in the basic examination of Korean medicine doctors, but there is no standardized method for diagnosing pulse although the types and methods of the pulse taking are briefly described in the literature, making it difficult to spread the examination method. In this regard, I would like to propose an objective evaluation method. Methods: Although the importance of pulse examination and the method of pulse examination are known in the literature, it is difficult for undergraduate students or inexperienced Korean medicine doctors to access it, so in this paper a method of marking the size of the pulse power in the blank space for objective evaluation was devised and presented. Results: The size of the pulse power should be indicated using the 1-cell, 3-cell, or 5-cell method according to the left and right wrists and the cun, guan and chi on both sides. Conclusion: The method of pulse diagnosis is an important diagnostic method as a verification process for making a Korean medical diagnosis. The remaining Korean medicine diagnostic methods, including pulse diagnosis, also need to undergo objectification. It is believed that the objectification of these diagnostic methods will lead to an improvement in the treatment rate of Korean medicine.

Implementation of Radial Pulse Diagnosis System using Inyoung-Cheongu Comparison Method (인영.촌구 대비법을 이용한 맥 진단 시스템 구현)

  • Lee, Ho-Jae;Park, Young-Bae;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.73-80
    • /
    • 1993
  • This paper describes the implementation of a computerized radial pulse diagnosis by Elds of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diag nosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed It. Then, we have got the characteristic parameters of radial pulse wave and also quantified thats according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial Pulse diagnosis system and then we confirmed the PossibiliLy for realization of automatic radial Pulse diagnosis in korean traditional medicine.

  • PDF

A Study for Performance Improvements in the Coaxial Type Stirling Pulse Tube Cryocooler (동축형 스털링 맥동관 냉동기의 성능개선에 관한 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Kim, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1329-1334
    • /
    • 2004
  • The most compact and convenient pulse tube cryocooler for practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. The experimental results of the coaxial inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature according to the variations of inertance tube volume, reservoir volume are measured, and the cool down characteristics at the particular conditions are presented. In case of the coaxial type inertance tube pulse tube refrigerator, cool down time is the lowest in the inertance tube diameter of 1.3 mm and inertance tube length of 1900 mm and lowest temperature is 112K. This results are not satisfactory for practical applications. So, We propose vacuum insulation between regenerator and pulse tube in the Stirling type coaxial pulse tube cryocooler. Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube was designed and manufactured by KIMM(Korea Institute of Machinery and Materials). The optimal conditions will be tested for Stirling type coaxial pulse tube cryocooler with the vacuum insulation between regenerator and pulse tube.

  • PDF

AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry (토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화)

  • Cho, JungHee;Jeon, Young Ju;Jun, Min-Ho;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

Generation of Ultrawide Band Electromagnetic Pulse from Blumlein Pulse Forming Line

  • Jin, Yun Sik;Kim, Jong Soo;Cho, Chuhyun;Roh, Young Su
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.677-681
    • /
    • 2014
  • A high voltage pulse generator was fabricated to radiate ultrawide band electromagnetic pulse. A coaxial type of Blumlein pulse forming line is employed to produce a pulse of high voltage (>300 kV) and short pulse duration (~5 ns). A helical strip/wire type of air-cored pulse transformer was used to charge the Blumlein pulse forming line up to more than 300 kV. A peaking switch is essential to make the pulse rise time as fast as possible. Typically, the rise time is ~500 ps. The output pulse of the generator is radiated into air through an exponentially tapered TEM horn antenna. The electric field intensity of a radiated pulse was measured as a function of the distance from the transmitting horn as well as the output voltage of the peaking switch. The peak-to-peak value of the electric field intensity at 10 m from the TEM antenna was~100 kV/m.