• Title/Summary/Keyword: The frequency

Search Result 65,892, Processing Time 0.07 seconds

Technological Trend of Optical Frequency Comb Generator (광 주파수 빗 발생기의 기술 동향)

  • Park, Jaegyu;Song, Minje;Han, Sang-Pil;Kim, Sungil;Song, Minhyup
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.5
    • /
    • pp.91-98
    • /
    • 2019
  • Optical frequency comb generators have been investigated as a signal source capable of generating highly stabilized ultrafast pulse lasers. The precise control of the optical frequency comb spacing by RF clock signals has led to a revolutionary paradigm shift in the precise measurement of time and frequency. Optical frequency combs also have advantages such as stable frequency spacing, stable number of lines, and robustness. Owing to these characteristics, optical frequency combs have been applied to the fields of high precision optical clock, communication, spectroscopy, waveform generation, and astronomy. In this article, we introduce the properties (i.e., generation methods, advantages, and so on) of various optical frequency combs, and discuss the expected future technological trends and applications.

Study on Bladder Dysfunction in Elderly Women by the BFLUT Questionnaire and Bladder Scanner: Frequency and Residual Urine (질문지법과 초음파 방광용적진단기를 이용한 여성노인의 배뇨장애연구 -빈뇨, 잔뇨를 중심으로)

  • Kim, Jeung-Im
    • Women's Health Nursing
    • /
    • v.17 no.3
    • /
    • pp.294-303
    • /
    • 2011
  • Purpose: This study aimed to describe bladder dysfunction in elderly women such as frequency, nocturia, and residual urine. Methods: One hundred elderly women aged 60 and over. The Bristol Female Lower Urinary Symptoms (BFLUT) was used to evaluate the bladder function and to measure the residual urine amount by using a bladder scanner. Data was analyzed with the differences between voiding dysfunction by age group and life habits by t-test, ANOVA and correlation by Pearson correlation coefficient. Results: the mean daytime frequency was 6.8 times and night-time frequency 2.7 times. Sixty three percent of subjects had urgency and 41% had urgent incontinence. Over half of subjects had problem in voiding function. There were significant differences in frequency by age groups and constipation, but not in daytime frequency and residual urine. Lastly, there were significant positive relations between daytime frequency and night-time frequency. Also results indicate that more frequency in daytime equaled to a less residual urine amount. Conclusion: We know many elderly women have lower urinary tract symptoms. Specially women over 75 years have more daytime frequency and night-time frequency. This suggests further research needed in order to understand the relation of voiding patterns and life habits and its influence on quality of life.

A Robust Target Motion Analysis Algorithm for Discontinuous Frequency Measurements (불연속적인 다중 주파수 측정치에 강인한 표적기동분석 알고리즘)

  • Cheong, Myoung-Jun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.372-379
    • /
    • 2011
  • Estimating underwater target state variables(position, velocity, course, etc) is necessary to counteract threatening targets. In passive sonar systems, conventional target motion analysis(TMA) techniques using bearing and frequency measurements of an underwater target are widely introduced. However, it is not clear how conventional TMA techniques can be used if some of frequency measurements are unavailable during parts of the scenario, partially unavailable frequency measurements are common in the ocean with complicated acoustic conditions where frequency measurements often come and go. This paper proposes a new TMA algorithm, which is robust to partially unavailable frequency measurements, using the frequency measurements fusion method.

Theoretical considerations on the giant magnetoimpedance effect in amorphous ribbons

  • Phan, Manh-Huong;Nguyen Cuong;Yu, Seong-Cho
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.60-61
    • /
    • 2003
  • Theoretical considerations on a giant magneto-impedance (GMI) effect in amorphous ribbons (i.e., thin films) have been made in terms of the expressions of effective permeability and impedance derived in the frame of classical electrodynamics and ferromagnetism. The dependence of GMI effect on the external do magnetic field (H$\_$ext/) and the frequency of alternating current are simulated and discussed in the knowledge of energy conversion consisting of the current energy loss, the ferromagnetic energy consumption, and the magnetic energy storage in the film. The obtained results are summarized as follow: (a) As frequency f< 20 ㎒, the real part of effective permeability (${\mu}$′) changes slightly. The peak of the ${\mu}$′curve always locates at H$\_$ext/=H$\_$ani/ - the anisotropy field. However, the peak value of ${\mu}$′ tends to increase with increasing frequency in the frequency range of 11-20 ㎒. (b) In the frequency range, f= 21-23 ㎒, a negative peak additionally appears. Meanwhile, both the positive and negative peak values rapidly increase with increasing frequency and their peak positions shift towards a high H$\_$ext/. (c) The positive peak value of ${\mu}$′ starts to decrease at f= 29 ㎒ and its negative peak does so at about 35 ㎒. Then, both peaks keep such a tendency and their peak positions move to high H$\_$ext/, as increasing frequency. (d) The dependence of the imaginary part of effective permeability (${\mu}$") on the external dc magnetic field and the frequency of the alternating field indicates that there is only one peak involved in ${\mu}$" for the whole frequency range. (e) The impedance vs. magnetic field curves at various frequencies show that there is a critical value of frequency around f= 18-19 ㎒ where the transition between two frequency regimes occurs; the one (low frequency) in which ${\mu}$′ predominantly contributes to the GMI effect and the other (high frequency) in which ${\mu}$" determines the GMI effect.

  • PDF

Mathematical Connection and Teaching Methods of Frequency Density (도수밀도(Frequency density)의 수학적 연결성과 지도방안)

  • Kim, Somin
    • Journal of the Korean School Mathematics Society
    • /
    • v.23 no.4
    • /
    • pp.509-521
    • /
    • 2020
  • This study began with the discovery of the concept of frequency density in Singapore textbooks and in a set of subject contents of the UK's General Certificate of Secondary Education. To understand the mathematical meaning of frequency density, the mathematical connection of frequency density was considered in terms of mathematics internal connections and mathematics external connections. In addition, the teaching method of frequency density was introduced. In terms of mathematical internal connections, the connections among the probability density function, relative frequency density, and frequency density in high school statistics were examined. Regarding mathematical external connections, the connection with the density concept in middle school science was analyzed. Based on the mathematical connection, the study suggested the need to introduce the frequency density concept. For the teaching method of frequency density, the Singapore secondary mathematics textbook was introduced. The Singapore textbook introduces frequency density to correctly represent and accurately interpret data in histograms with unequal class intervals. Therefore, by introducing frequency density, Korea can consistently teach probability density function, relative frequency density, and frequency density, emphasizing the mathematical internal connections among them and considering the external connections with the science subject. Furthermore, as a teaching method of frequency density, we can consider the method provided in the Singapore textbook.

Frequency Effects of Upstream Wake and Blade Interaction on the Unsteady Boundary Layer Flow

  • Kang, Dong-Jin;Bae, Sang-Su
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1303-1313
    • /
    • 2002
  • Effects of the reduced frequency of upstream wake on downstream unsteady boundary layer flow were simulated by using a Wavier-Stokes code. The Wavier-Stokes code is based on an unstructured finite volume method and uses a low Reynolds number turbulence model to close the momentum equations. The geometry used in this paper is the MIT flapping foil experimental set-up and the reduced frequency of the upstream wake is varied in the range of 0.91 to 10.86 to study its effect on the unsteady boundary layer flow. Numerical solutions show that they can be divided into two categories. One is so called the low frequency solution, and behaves quite similar to a Stokes layer. Its characteristics is found to be quite similar to those due to either a temporal or spatial wave. The low frequency solutions are observed clearly when the reduced frequency is smaller than 3.26. The other one is the high frequency solution. It is observed for the reduced frequency larger than 7.24. It shows a sudden shift of the phase angle of the unsteady velocity around the edge of the boundary layer. The shift of phase angle is about 180 degree, and leads to separation of the boundary layer flow from corresponding outer flow. The high frequency solution shows the characteristics of a temporal wave whose wave length is half of the upstream frequency. This characteristics of the high frequency solution is found to be caused by the strong interaction between unsteady vortices. This strong interaction also leads to destroy of the upstream wake strips inside the viscous sublayer as well as the buffer layer.

Study on improvement of frequency response characteristics of accelerometer (진동가속도계의 주파수응답특성 개선에 관한 연구)

  • 한응교;조진호
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.3 no.1
    • /
    • pp.61-68
    • /
    • 1981
  • There are three types in frequency response accelerometer; one is lightly damped piezp type, another is oil damping stainguage type and the third is electro induction type accelerometer within electromagnetic damping. The usable frequency range of lightly damped accelerometers is limited to 0.2 of their mounted natural frequency for amplitude distortion of less than 5 percents. There have been situation where the measured motion contains unforeseen high - frequency components, which are regarded as such due to the accelerometer transfer function. There are several way to overcome amplitude distortion of the higher than anticipated frequency components; (I) to make use of the accelerometer with natural frequency three times and more as high as the measured frequency, (II) to establish data-analysis techniques which will account for the amplitude distortion, (III) to set up a notch filter circuit which has a transfer function that is the reciprocal of the accelerometer transfer function, and so on. This paper makes a report of the method as to(III), i. e., set up a few notch filter circuits, it is discussed what happens when the transfer functions, are in discord as to natural frequency of the filter and accelerometer damping vs. filter damping. And especially as for the cantilever strain gauge type accelerometer made by oneself with ease, it was compared and discussed between the ideological value and the experimental value of actual designed circuit in case of the mismatching of the transfer functions, and it was considered whether to be practicable or not, the result of which was as following; the useful frequency range of the accelerometer can be extended to near resonance if (a) the accelerometer mounted natural frequency and the filter center frequency are matched within .+-. 2 percent and (b) the damping ratios are matched within two factors. Therefore, we obtained the good result in improvement for extending frequency response characteristics of accelerometer.

  • PDF

Estimation of Ionospheric Delays in Dual Frequency Positioning - Future Possibility of Using Pseudo Range Measurements -

  • Isshiki, Hiroshi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.185-190
    • /
    • 2006
  • The correct estimation of the ionospheric delays is very important for the precise kinematic positioning especially in case of the long baseline. In case of triple frequency system, the ionospheric delays can be estimated from the measurements, but, in case of dual frequency system, the situation is not so simple. The precision of those supplied by the external information source such as IONEX is not sufficient. The high frequency component is neglected, and the precision of the low frequency component is not sufficient for the long baseline positioning. On the other hand, the high frequency component can be estimated from the phase range measurements. If the low frequency components are estimated by using the external information source or pseudo range measurements, a more reasonable estimation of the ionospheric delays may be possible. It has already been discussed by the author that the estimation of the low frequency components by using the external information source is not sufficient but fairly effective. The estimation using the pseudo range measurements is discussed in the present paper. The accuracy is not sufficient at present because of the errors in the pseudo range measurements. It is clarified that the bias errors in the pseudo range measurements are responsible for the poor accuracy of the ionospheric delays. However, if the accuracy of the pseudo range measurements is improved in future, the method would become very promising.

  • PDF

Experimental investigation of the whirl and generated forces of rotating cylinders in still water and in flow

  • Chen, Wei;Rheem, Chang-Kyu;Lin, Yongshui;Li, Ying
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.531-540
    • /
    • 2020
  • The whirl and generated forces of rotating cylinders with different diameters placed in still water and in flow are studied experimentally. For the rotating cylinders in still water, the Same Frequency Whirl (SFW) and Different Frequency Whirl (DFW) have been identified and illustrated. The corresponding SFW and DFW areas are divided. The Root Mean Square (RMS) values of the generated force coefficient dramatically increase in the defined ranges of Resonance I and Resonance II. For the rotating cylinders in flow, the hydrodynamics, SFW and DFW are illustrated. The hydrodynamic, SFW and DFW areas are divided. The RMS values of the generated forces in the range of Resonance II are much smaller than those in still water due to the generated lift forces. The discussion suggests that the frequency of the DFW may equal multiple times or one-multiple times that of the rotating frequency: the whirl direction of the DFW with multiple times the frequency of the rotating frequency is the same as the rotating direction. The whirl direction of the DFW with one-multiple times frequency of the rotating frequency is opposite to the rotating direction.

Frequency-dependent grounding impedance of the counterpoise based on the dispersed currents

  • Choi, Jong-Hyuk;Lee, Bok-Hee;Paek, Seung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.589-595
    • /
    • 2012
  • When surges and electromagnetic pulses from lightning or power conversion devices are considered, it is desirable to evaluate grounding system performance as grounding impedance. In the case of large-sized grounding electrodes or long counterpoises, the grounding impedance is increased with increasing the frequency of injected current. The grounding impedance is increased by the inductance of grounding electrodes. This paper presents the measured results of frequency-dependent grounding impedance and impedance phase as a function of the length of counterpoises. In order to analyze the frequency-dependent grounding impedance of the counterpoises, the frequency-dependent current dissipation rates were measured and simulated by the distributed parameter circuit model reflecting the frequency-dependent relative resistivity and permittivity of soil. As a result, the ground current dissipation rate is proportional to the soil resistivity near the counterpoises in a low frequency. On the other hand, the ground current dissipation near the injection point is increased as the frequency of injected current increases. Since the high frequency ground current cannot reach the far end of long counterpoise, the grounding impedance of long counterpoise approaches that of the short one in the high frequency. The results obtained from this work could be applied in design of grounding systems.