Application and evaluation of machine-learning model for fire accelerant classification from GC-MS data of fire residue

  • Park, Chihyun;Park, Wooyong;Jeon, Sookyung;Lee, Sumin;Lee, Joon-Bae
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.231-239
    • /
    • 2021
  • Detection of fire accelerants from fire residues is critical to determine whether the case was arson or accidental fire. However, to develop a standardized model for determining the presence or absence of fire accelerants was not easy because of high temperature which cause disappearance or combustion of components of fire accelerants. In this study, logistic regression, random forest, and support vector machine models were trained and evaluated from a total of 728 GC-MS analysis data obtained from actual fire residues. Mean classification accuracies of the three models were 63 %, 81 %, and 84 %, respectively, and in particular, mean AU-PR values of the three models were evaluated as 0.68, 0.86, and 0.86, respectively, showing fine performances of random forest and support vector machine models.

Case study of cyanide detection in fatalities by fire in Korea

  • Kim, Dong-Woo;Baeck, Seung-Kyung;Kim, Sun-Chun;Seo, Joong-Seok
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.168.2-169
    • /
    • 2003
  • Hydrogen cyanide is one of the toxic agents with carbon monooxide in fire victims and is released by combustion of nitrogen-containing organic material such as plastic and wool. Until now there are few reports about blood cyanide concentrations in fatalities by fire in Korea. So in this study we examined blood cyanide concentration in 12 cases of fire fatalities. (omitted)

  • PDF

Toxicological Study for Blood Cyanide and Carboxyhemoglobin Levels in the Fire- related Fatalities

  • Baeck, Seung-Kyung;Kim, Dong-Woo;Kim, Sun-Chun;Park, Woo-Yong;Jin, Kwang-Ho;Chung, Young-Ho;Park, Yun-Shin;Seo, Joong-Seok
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.170.2-170.2
    • /
    • 2003
  • The most common cause of death in fires is the inhalation of noxious gases rather than thermal injury. Carbon monoxide is well-known toxic component in fire atmospheres. However, the importance of hydrogen cyanide(HCN) as a toxic agent in the fire related fatalities(FRF) is under discussion. HCN is known to be produced in fires involving by the pyrolysis of polyacrylonitril (PAN) and other nitrogen-containing polymer. (omitted)

  • PDF

A Study on the Cooling Load Generation for Efficient Energy Management (냉방부하 수요 창출을 통한 효율적 에너지 관리방안 연구)

  • Woo, Nam-Sub;Kim, Yong-Ki;Lee, Tae-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1007-1012
    • /
    • 2008
  • Demand for the highly efficient and high performance urban energy supply system having been continuously increased according to the rise of quality of life and continuously increased energy cost all over the world. The district heating and cooling system is very effective way for energy saving, cost reduction, and demand side management of energy. There are several district cooling supply technologies such as chilled water direct transportation, installation of absorption type chiller in the user side, and desiccant cooling. This study investigates the advantage and technical problems of each district cooling technology. Also, it is necessary political and financial support system for the extension of district cooling system.

  • PDF

Simulation of Indoor Shooting Range Fire in Busan by Using FDS (FDS를 이용한 부산 실내사격장 화재 시뮬레이션)

  • Cho, Young-Jin;Seo, Young-Il;Moon, Byung-Sun;Kim, Sung-Jin;Jeon, Woo-Jeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.143-146
    • /
    • 2011
  • 2009년 11월 14일 발생한 부산 실내사격장 화재와 관련하여 조사내용을 토대로 화재 시뮬레이션용 전선유체역학 모델인 FDS를 이용하여 재현하였으며, 시뮬레이션 결과와 화재당시 녹화된 CCTV 영상을 비교하였다. 2층 발사실에서 시작된 화재는 급격히 연소가 진행되어 약 3초 후에 휴게실로 확산되며, 약 7초 후에는 계단 및 1층 홀을 지나 사람들이 통행하는 인도에까지 연기가 분출되는 것으로 나타났다. 시뮬레이션 결과는 2층 발사실과 휴게실에 녹화된 CCTV 영상 및 1층 홀 옆의 귀금속가게에 녹화된 CCTV 영상과 거의 일치하였다.

  • PDF

Analysis of Spatial Characteristics of Old Building Districts in Daegu to Evaluate Fire Risk Factors (화재위험요소의 도출을 위한 대구지역 노후건축지구의 공간특성분석)

  • Son, Byeung-Hun;Kang, Kyung-Ha;Ryu, Jung-Rim;Roh, Seung-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.202-203
    • /
    • 2021
  • The proportion of old buildings over 30 years old increased from 29.0% in 2005 to 37.8% in 2019. These old buildings were created during the absence of building-related safety standards such as fire safety performance. In the process of use, illegal changes and extensions were made, making them more vulnerable to safety. In the 1st Basic Plan for Fire Safety Policy, among the 12-Key Tasks, one is to ensure the safety of residential living spaces. Fire safety investigations are being conducted to prevent large-scale disasters such as multi-use buildings, but no investigation has been conducted at the regional district level where small-scale old buildings are concentrated. Therefore, in order to derive fire risk factors in the old building district where old buildings are concentrated, the composition characteristics of the buildings were first analyzed.

  • PDF

Fire District Adjustment for Improving Fire Service Vulnerable Areas in Jinju (진주시 소방서비스 취약지역 개선을 위한 소방권역 조정)

  • Yoo, Hwan Hee;Koo, Seul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.21 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • This study analyzed the vulnerable areas to the fire service in regard to 119 safety centers, currently established in Jinju city. In this study, the district of fire was examined through the analysis of the OD cost matrix to find the transference or increase methods of the existing centers for improving the fire services. The study results demonstrate that the numbers of 119 safety centers were lacking in comparison with the areas of the administrative district in Jinju. In particular, relocation and the transference or increase of centers were required for the Cheonjeon 119 safety centers, which is the creation area of the National Industrial Complex among five 119 safety centers located in Jinju, and the fire service jurisdiction of Munsan 119 safety centers (including Banseong 119 regional unit), which is the location of a big fire risk due to the increase of population according to the development of the new town. In addition, the OD cost matrix analysis in this study reveals the fact that the time of fire service in the Jeonchon Industrial Complex, which is the significantly vulnerable area, will be reduced from 8 minutes to 3.3 minutes if the current Cheonjeon 119 safety center is moved to Gaho-dong. It indicates that the increase of safety centers in Geumsan-myeon areas, where the population has increased rapidly in recent days due to the development of the new town, is keenly needed.

A Development of the Guideline for the Heating Water Quality in Apartment Houses with District Heating System (공동주택 지역난방 수질기준 설정에 관한 연구)

  • Kim, Yong-Ki;Lee, Tae-Won;Woo, Dal-Sik;Oh, June;Ahn, Chang-Koo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.493-498
    • /
    • 2008
  • Particles or deposit formed by corrosion of the pipe material bring about bad influences on the heating systems with inconvenience, energy loss and so on. In order to obtain the non-corrosive environments, the circulation hot water should properly be treated in several ways to satisfy one or more conditions of the followings: suitable pH-level, low hardness, low oxygen content, low conductivity, low level of chlorides and sulphur compounds and low level of solid particles. This experimental study was carried out to develope the new guidelines on the optimal water quality and directions for water quality management in heating systems. As results, it was recommended that the heating water be maintained pH-level not less than 8, hardness contents as $CaCO_3$ no more than 50 mg/L, turbidity no more than 10 NTU and T-Fe contents 1 mg/L below.

  • PDF