• Title/Summary/Keyword: The current school facility

Search Result 169, Processing Time 0.026 seconds

SUGGESTION OF REGISTERED DENTIST PROGRAM FOR THE DISABLED: BASED ON THE NEEDS OF CONSUMERS AND SUPPLIERS (수요자와 공급자 대상 요구조사를 통한 장애인 치과주치의제도의 제안)

  • Kim, SoYun;Paik, Hye-Ran;Jin, Bo-Hyoung;Lee, Jae-Young;Kim, Jihyun;Kim, Young-Jae
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.14 no.2
    • /
    • pp.59-64
    • /
    • 2018
  • This study proposed a registered dentist model for the disabled based on consumer in-depth interview and supplier survey. This study proposed that dental clinics in the community take role as registered dentists for the disabled. Qualification screening and facility prerequisites are required to be selected as the registered dentists for the disabled and patients of the registered dentists were restricted to the disabled who can cooperate to dental treatment services with or without the aid of physical bondage. In order to encourage the participation in the program, subsidies for the registered dentists were necessary. Also, this study proposed financial supports for the medical expenses for patients at the same level as the current dental care center for the disabled. The registered dentist program for the disabled meets the needs of disabled consumers, such as accessibility of medical institutions, expertise of medical staff, and ongoing treatments with familiar medical staff. The registered dentist program for the disabled is expected to provide prevention and ongoing management for oral health promotion of disabled people and it also contribute to lower economic burden of oral health care of the disabled.

Analysis of the Current Situation about the Computer Education of Commercial High School placing empasis on Gwang-Ju city area (상업계 고등학교 컴퓨터 교육에 관한 현황분석(광주광역시 중심))

  • Ahn, Ju-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.906-909
    • /
    • 2007
  • The method of distributing some questionnaires to the total 4 schools in the area of Gwang-ju city and then collect them later has been used in this study. By using the coefficient of Cronbach's alpha for the collected data, the trust rate of the method of questionnaires have been verified. In conclusion it's been analized that there are disparities in 'computer education course, professor lesson, possibility of computer use, teaching obstacles, self development of teachers, choice and organization of the computer education contents' according to the general situation of the teachers who charge computer education sand there are also disparities in 'goal of computer education, computer curriculum related learning activity, computer curriculum related learning satisfaction, practical use of computer facility, interested contents of students, other lessons besides regular education course' according to the general situation of the students who receive computer education in commercial high school.

  • PDF

Wind Load Analysis of 61ton-class Container Crane using the Computation Fluid Dynamics (61ton 컨테이너 크레인의 전산유동해석을 통한 풍하중 분석)

  • Lee, Su-Hong;Lee, Seong-Wook;Han, Dong-Seop;Kim, Tae-Hyung;Han, Geun-Jo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.3
    • /
    • pp.251-255
    • /
    • 2008
  • Container cranes are vulnerable structure about difficult weather conditions bemuse there is no shielding facility to protect them from the strong wind. This study was carried out to analyze the wind load which have an effect on container crane according to the various wind direction. The container crane is a model of a 61-ton class that used broadly in the current ports. The external fluid field was figured as a cylinder which was set up $500m{\times}200m$. In this study, we applied mean wind load conformed to 'Design Criteria of Wind Load' in 'Load Criteria of Building Structures' and an external fluid field was divided as interval of 10 degrees to analyze effect according to a wind direction In this conditions, we carried out the computation fluid dynamic analysis using the CFX-10. As we compared computation fluid dynamic analysis with wind tunnel test, we analyzed the wind load which was needed to design the container crane.

Wind Load Analysis of 61ton-class Container Crane using the Computation Fluid Dynamics (61ton 컨테이너 크레인의 전산유동해석을 통한 풍하중 분석)

  • Lee, Su-Hong;Lee, Seong-Wook;Han, Dong-Seop;Kim, Tae-Hyung;Han, Geun-Jo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2007.12a
    • /
    • pp.228-229
    • /
    • 2007
  • Container cranes are vulnerable structure to difficult weather conditions because there is no shielding facility to protect them from high wind This study carried out to analyze the wind load have an effect on container crane according to a wind direction variation The container crane for this research is a model of a 61-ton class tint used broadly in the current ports. The dimension of an external fluid field set up 500m ${\times}$ 200m. In this study, Mean wind load conformed to the 'Design Criteria of Wind Load' in 'Load Criteria of Building Structures' and an external fluid field divided in interval of 10 degrees to analyze effect according to a wind direction From there, we carried out to the computation fluid dynamic analysis using a CFX-10 Therefore as consequence of computation fluid dynamic analysis and wind velocity experiment make a comparative study, we analyzed a wind load for construction design if container crane.

  • PDF

A Study of the Detailed Typology of School Outdoor Spaces - For a Recent Landscaping School in Seoul - (학교옥외공간의 세부 유형 분류 연구 - 서울시 최근 조경사업 학교를 대상으로 -)

  • Ahn, Myung June
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.4
    • /
    • pp.56-68
    • /
    • 2024
  • This study aimed to derive the concept and types of school outdoor spaces in Seoul. The research results showed that the concept of school outdoor space can be viewed as an outdoor activity space in schools that secures the value of integrated public life and communal life, including "behavioral rights, walking rights, living rights, urban rights, landscape rights (viewing rights), and nature experience rights." It can also be defined as a basic educational space that reflects the value of education, which is the basic function of schools and the characteristics of the community. As a result of the analysis based on the general types of outdoor spaces, it was found that the outdoor spaces of Seoul schools can be divided into three major categories: walking space (movement function), educational space (educational activities), and rest and other spaces (other services). Based on this, outdoor spaces were categorized and subcategorized to serve as the basis for policy implementation. These classifications are characterized by 1) simplifying the classification of spaces by function into three (movement functions, educational activities, and other services) to enable the use of outdoor spaces for integrated purposes; 2) reflecting the complex use of spaces by subdividing educational spaces focusing on major activities, and in particular, discovering complex spaces due to the three-dimensionalization of buildings; and 3) enabling spatial-level planning and facility element-level access according to school characteristics. It is characterized by applying the recent trends and systems of general outdoor space projects to the current situation of schools.

Palliative Care for Patients with Gynecologic Cancer in Japan: A Japan Society of Gynecologic Palliative Medicine (JSGPM) Survey

  • Futagami, Masayuki;Yokoyama, Yoshihito;Sato, Tetsumi;Hirota, Kazuyoshi;Shimada, Muneaki;Miyagi, Etsuko;Suzuki, Nao;Fujimura, Masaki
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.10
    • /
    • pp.4637-4642
    • /
    • 2016
  • Purpose: To evaluate palliative care for patients with gynecologic cancer in Japan. Materials and Method: A questionnaire asking facility characteristics, systems to coordinate palliative care, current status of end-of-life care, provision of symptom relief, palliative radiation therapy and chemotherapy, and cases of death from gynecological cancer, was mailed to facilities treating gynecologic cancer. Results: A total of 115 facilities (29.3% of the total) responded to the questionnaire. Of these, 33.0 (29.0%) had a palliative care ward. End-of-life care was managed by obstetricians and gynecologists in 72.0% of the facilities. The site where end-of-life care was provided was most often a ward in the department where the respondent worked. The waiting period for transfer to a hospice was 2 weeks or more in 52% of facilities. Before the start of primary treatment, pain control was managed by obstetrians and gynecologists in 98.0% of facilities. Palliative radiation therapy or chemotherapy was administered at 93.9% and 92.0% of facilities, respectively. Of the 115 facilities, 34.0 (29.6%) reported cases of death from gynecological cancer. There were 1,134 cases of death. The median time between the last cycle of chemotherapy and death was 85 days for all gynecological cancers. The proportion of patients receiving chemotherapy in the last 30 and 14 days of life were 17.4% and 7.1%, respectively. Conclusions: This large-scale survey showed characteristics of palliative care given to patients with gynecologic cancer in Japan. Assessment of death cases showed that the median time between the last cycle of chemotherapy and death was relatively short.

Current Practices in Breast Magnetic Resonance Imaging: a Survey Involving the Korean Society of Breast Imaging

  • Yun, Bo La;Kim, Sun Mi;Jang, Mijung;Kang, Bong Joo;Cho, Nariya;Kim, Sung Hun;Koo, Hye Ryoung;Chae, Eun Young;Ko, Eun Sook;Han, Boo-Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.233-241
    • /
    • 2017
  • Purpose: To report on the current practices in breast magnetic resonance imaging (MRI) in Korea. Materials and Methods: We invited the 68 members of the Korean Society of Breast Imaging who were working in hospitals with available breast MRI to participate in a survey on how they performed and interpreted breast MRI. We asked one member from each hospital to respond to the survey. A total of 22 surveys from 22 hospitals were analyzed. Results: Out of 22 hospitals, 13 (59.1%) performed at least 300 breast MRI examinations per year, and 5 out of 22 (22.7%) performed > 1200 per year. Out of 31 machines, 14 (45.2%) machines were 1.5-T scanners and 17 (54.8%) were 3.0-T scanners. All hospitals did contrast-enhanced breast MRI. Full-time breast radiologists supervised the performance and interpreted breast MRI in 19 of 22 (86.4%) of hospitals. All hospitals used BI-RADS for MRI interpretation. For computer-aided detection (CAD), 13 (59.1%) hospitals sometimes or always use it and 9 (40.9%) hospitals did not use CAD. Two (9.1%) and twelve (54.5%) hospitals never and rarely interpreted breast MRI without correlating the mammography or ultrasound, respectively. The majority of respondents rarely (13/21, 61.9%) or never (5/21, 23.8%) interpreted breast MRI performed at an outside facility. Of the hospitals performing contrast-enhanced examinations, 15 of 22 (68.2%) did not perform MRI-guided interventional procedures. Conclusion: Breast MRI is extensively performed in Korea. The indication and practical patterns are diverse. The information from this survey would provide the basis for the development of Korean breast MRI practice guidelines.

An Analysis on Current Status of Certification for Green Building Revitalization in School - Focused on the School Located in Gyeonggi-do Province - (학교시설의 녹색건축 활성화를 위한 인증현황 분석 연구 - 경기도 학교시설을 중심으로 -)

  • Kim, Jang-Young;Kim, Sung-Joong;Lee, Seung-Min
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.14 no.3
    • /
    • pp.9-17
    • /
    • 2015
  • In this paper, there are several analysis on G-SEED, Building Energy Efficiency Rating System, Energy Performance Index, Energy Saving Plan about how they are applied by classification and planning standard. The analysis result found out that G-SEED has low select percentage by having difficulties to managing and additional cost when the each class is selected. And also, Building Energy Efficiency Rating System in school is planed in comparably simple design and similar size and also mostly uses high efficient machines, which was in high lever comparing to the system in facilities in other uses. In the case of EPI, there are differences on acquiring grades by each region. Especially, Gyung-gi region has a low grade on architecture part comparing to other parts, which seems to acquire more grades by strengthen insulation performance. By the result from the three standards, many facilities has only formal plan to pass the required standard without considering specialities of each buildings, which has a tendency to have a pattern to have a minimum criteria. However, School has a symbolic building which has a obligation to be the base of the aim for growing green energy buildings and green education for students. Therefore, planning with understanding of specialities of the facility, having various and rational evaluation standards from the planning of the building is necessary.

Comparative Analysis on the Perspectives of Hospitals and Contractors on Items related with Contracting Hospital Foodservice Management (병원급식 위탁계약에 대한 병원과 위탁회사의 견해 비교 분석)

  • Kim, Hyeon-A;Kim, Jin-Su;Yang, Il-Seon;Park, Mun-Gyeong;Park, Su-Yeon
    • Journal of the Korean Dietetic Association
    • /
    • v.10 no.3
    • /
    • pp.293-299
    • /
    • 2004
  • The purposes of this study were to : a) investigate the current status of contracted hospital food services, b) analyze and clarify various perspectives of contractors and hospitals. Thirty six hospitals and their contractors which were having more than 100 beds located in Seoul, Inchon and Kyungkido, were the subjects of this study. Data were collected through surveys. The survey was conducted during March to April in 2002. Questionnaires were mailed to the 36 directors of dietetic departments of hospitals and 36 managers of contract foodservice management company. Statistical analysis was completed using SPSS Win(11.0) for descriptive analysis, t-test and $x^2$-test. The results of the study can be summarized ; 1. The type of contract considered adequate by directors of dietetic departments and managers of contractors was fee-contract, combined type, followed by profit-and-loss contract. 2. According to the results from analysis on the contract cost per meal considered adequate by directors of dietetic departments and managers, the directors of dietetic department indicated that showing no difference with the current contract cost per meal. However, the managers of contractor indicated that showing significant differences compared with the current contract cost per meal(regular diet p<0.01, therapeutic diet p<0.001). 3. In the composition of contract cost per meal considered adequate, the managers of contracting businesses accounted labor cost (p<0.01) as a major cost, whereas the chiefs of nutrition departments accounted miscellaneous or controllable expense (p<0.001) and VAT (p<0.01) as major costs. 4. The directors of dietetic departments and managers thought that the hospital should be responsible for utility costs. On the other hand, directors of dietetic departments regarded that the contractor and managers thought that the hospital should pay for facility investment cost.

  • PDF

A CFD Study on Aerodynamic Performances by Geometrical Configuration of Guide Vanes in a Denitrification Facility (탈질 설비 내 안내 깃의 기하학적 형상에 따른 공력 성능에 대한 전산 해석적 연구)

  • Chang-Sik, Lee;Min-Kyu, Kim;Byung-Hee, Ahn;Hee-Taeg, Chung
    • Clean Technology
    • /
    • v.28 no.4
    • /
    • pp.316-322
    • /
    • 2022
  • The flow pattern at the inlet of the catalyst layer in a selective catalytic reduction (SCR) system is one of the key parameters influencing the performance of the denitrification process. In the curved diffusing parts between the ammonia injection grids and the catalyst layers, guide vanes are installed to improve flow uniformity. In the present study, a numerical simulation has been performed to investigate the effect of the geometrical configuration of the guide vanes on the aerodynamic characteristics of a denitrification facility. This application has been made to the existing SCR process in a large-scaled coal-fired power plant. The flow domain to be solved covers the whole region of the flow passages from the exit of the ammonia injection gun to the exit of the catalyst layers. ANSYS-Fluent was used to calculate the three-dimensional steady viscous flow fields with the proper turbulence model fitted to the flow characteristics. The root mean square of velocity and the pressure drop inside the flow passages were chosen as the key performance parameters. Four types of guides vanes were proposed to improve the flow quality compared to the current configuration. The numerical results showed that the type 4 configuration was the most effective at improving the aerodynamic performance in terms of flow uniformity and pressure loss.