• Title/Summary/Keyword: The Grid

Search Result 9,357, Processing Time 0.048 seconds

Fuzzy Logic-based Grid Job Scheduling Model for omputational Grid (계산 그리드를 위한 퍼지로직 기반의 그리드 작업 스케줄링 모델)

  • Park, Yang-Jae;Jang, Sung-Ho;Cho, Kyu-Cheol;Lee, Jong-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.5
    • /
    • pp.49-56
    • /
    • 2007
  • This paper deals with grid job allocation and grid resource scheduling to provide a stable and quicker job processing service to grid users. In this paper, we proposed a fuzzy logic-based grid job scheduling model for an effective job scheduling in computational grid environment. The fuzzy logic-based grid job scheduling model measures resource efficiency of all grid resources by a fuzzy logic system based on diverse input parameters like CPU speed and network latency and divides resources into several groups by resource efficiency. And, the model allocates jobs to resources of a group with the highest resource efficiency. For performance evaluation, we implemented the fuzzy logic-based grid job scheduling model on the DEVS modeling and simulation environment and measured reduction rates of turnaround time, job loss, and communication messages in comparison with existing job scheduling models such as the random scheduling model and the MCT(Minimum Completion time) model. Experiment results that the proposed model is useful to improve the QoS of the grid job processing service.

  • PDF

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

OAuth based Proxy Delegation Service (OAuth 기반의 대리 인증서 위임 서비스)

  • Heo, Daeyoung;Hwang, Suntae
    • Journal of Internet Computing and Services
    • /
    • v.13 no.6
    • /
    • pp.55-62
    • /
    • 2012
  • Grid web applications by standard Web technology are increasingly used to provide grid service to users as normal Web user interface and service. It is however difficult to integrate a grid security system such as Grid Security Infrastructure (GSI) into Web applications because the delegation way of standard Web security is not the same as the one of Grid security. This can be solved by allowing Web applications to get a Grid credential by using an online credential repository system such as MyProxy. In this paper, we investigate the problem that occurs when MyProxy, which assumes mutual trust between a user and Grid web application, is adapted for achieving security integration between Web and Grid, and we propose a new Grid proxy delegation service to delegate a Grid credential to the Web without assuming mutual trust. In the service, the X.509 proxy delegation process is added to OAuth protocol for credential exchange, and authentication can be done by an external service such as OpenID. So, users can login onto the Grid web application in a single sign-on manner, and are allowed to securely delegate and retrieve multiple credentials for one or more Virtual Organizations.

Methodology of requirements analysis for AMI development and Use (AMI 시스템 개발을 위한 요구분석 방법론 및 응용방안)

  • Jung, Nam-Joon;Back, Nam-Ok;Choi, Min-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1989-1990
    • /
    • 2011
  • 스마트그리드 즉, 미래 지능형 전력시스템이 추구하는 가장 큰 특징은 표준화 기반의 시스템간 상호운용성과 최신 기술을 이용한 자동화라고 할 수 있겠다. 그러므로 시스템간 상호 운용이 가능한 스마트그리드 시스템의 개발을 위해서는 요구분석부터 전반적인 시스템의 조건을 만족할 수 있도록 고려되어야 한다. 스마트그리드를 위한 전력시스템의 개발에 활용 될 수 있는 방법론으로는 'IEC 62559 IntelliGrid Methodology(IntelliGrid$^{SM}$, 이하 IntelliGrid 방법론)'이 있다. IntelliGrid 방법론은 IEC에 의하여 2007년에 채택된 전력에너지시스템 개발을 위한 방법론(IEC 62559, PAS(Publicly Available Specification))으로, EPRI의 'IntelliGrid 프로그램'의 산출물이다. IntelliGrid 방법론에 기반한 요구분석 방법론을 체계적인 스마트그리드 시스템 개발을 위한 요구분석 방안을 제시한 결과물로 평가할 수 있다. 본 논문에서는 IntelliGrid 방법론의 내용을 분석해 보고, AMI 개발을 위한 요구분석 방법론으로 'IntelliGrid 방법론'을 적용하는 방안 및 절차에 관하여 제시하고자 한다.

  • PDF

Review on Integration of Smart Grid into Smart City (스마트 그리드(스마트 에너지)의 스마트 시티에의 통합에 대한 문헌 연구)

  • Sim, Min Kyu
    • The Journal of Society for e-Business Studies
    • /
    • v.25 no.1
    • /
    • pp.35-43
    • /
    • 2020
  • Smart grid aims to achieve efficient energy-related operations. Smart grid will become a central component of Smart city that aims to improve citizens' quality of life. This paper validates that smart grid at matured state is the state where smart grid is naturally integrated into smart grid. Also, this paper describes smart grid as an essential element of smart city. This paper discusses necessary social infrastructure and investigates necessary technological features.

DC Fault Study in Point-to-Point HVDC Grid based on MMC VSC (MMC VSC 기반 Point-to-Point HVDC Grid에서의 DC 고장 분석)

  • Lee, Dong-Su;Kim, Ki-Suk;Jang, Gil-soo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.161-162
    • /
    • 2015
  • 최근 세계적으로 전력계통의 대륙 간 연계나 신재생에너지, 분산전원의 계통 연계를 위해 HVDC(High voltage Direct Current)에 대한 연구가 활발히 진행되고 있다. 대용량, 장거리 송전이 필요한 경우 HVAC에서의 전력손실과 송전거리의 한계를 극복하기 위하여 HVDC가 새로운 대안으로 떠오르고 있으며, LCC(Line commutated Converter)와 VSC(Voltage Source Converter)의 기술발전이 비약적으로 이뤄지고 있다. 특히, DC Grid화를 위해서 유럽에서는 해상풍력을 연계한 Windfarm을 DC Grid화 하는 프로젝트가 활발히 진행되고 있다. 이러한 신재생 에너지의 계통 연계를 위해서 DC Grid가 본격적으로 논의가 되고 있고 관련분야에서는 기술개발을 앞다퉈 진행하고 있는 상황이다. DC Grid 구현을 위해 VSC HVDC가 최근 주목받고 있으며, VSC로 연계된 DC Grid의 AC 계통과의 연계를 위해 가장 필요한 것이 바로 DC 차단기라고 할 수 있겠다. 본 논문에서는 DC Grid의 고장분석을 위한 기초연구로써 MMC(Modular Multilevel Converter) VSC를 기반으로 한 Point-to-Point HVDC Grid에서의 DC 고장에 대한 분석을 실시하였으며 그 특징을 분석하였다.

  • PDF

WGridSP: A Web-based Scheduling Platform for Grid Computing (WGridSP: 그리드 컴퓨팅을 위한 웹 기반 스케줄링 플랫폼)

  • Kang, Oh-Han;Kang, Sang-Seong
    • The KIPS Transactions:PartA
    • /
    • v.13A no.5 s.102
    • /
    • pp.381-386
    • /
    • 2006
  • In this paper, we designed and implemented a web-based grid scheduling platform(WGridSP), which can model a system and simulate scheduling scheme in grid computing. WGridSP used GridSim, a grid scheduling toolkit in java-environment, as a tool for simulation and is able to Perform resource modeling, task modeling, algorithm compiling, simulation, and Performance evaluation rapidly in web environment. WGridSP can be applied as a foundation for grid research and can be used to analyze the efficiency of scheduling algorithm.

An Impact Analysis of Community Energy System (CES) on The Grid (지역 에너지 시스템(CommunityEnergysystem)의 개통 연계 운전 특성)

  • Park Y. U.;Kim K. H.;Jang S. I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.120-122
    • /
    • 2004
  • This paper analyse impacts of Community Energy System (CES) on the grid during transition periods for integrating of the CES and the grid. In the near future, CES might be one of major energy supply structures. The basic concept of CES is that it supplies electrical and thermal energy to the local customer loads through the islanded power network separated from the grid. Therefore, the interconnection with the grid occurs only when the energy supply from the CES generators does not meet the demand of the local load. For avoiding impacting the grid during the transition operation modes of CES, it is necessary to thoroughly analyse the influences on the grid during those periods. In order to show them, in this paper, we model the CES with 2.34 WVA DG and simulate the impacts on the grid due to interconnection of CES The simulation results show that, in order to reduce bad influences of CES on the grid, CES need the efficient load management and generation control schemes during the transition periods.

  • PDF

Voltage Feedforward Control with Time-Delay Compensation for Grid-Connected Converters

  • Yang, Shude;Tong, Xiangqian
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1833-1842
    • /
    • 2016
  • In grid-connected converter control, grid voltage feedforward is usually introduced to suppress the influence of grid voltage distortion on the converter's grid-side AC current. However, owing to the time-delay in control systems, the suppression effect of the grid voltage distortion is seriously affected. In this paper, the positive effects of the grid voltage feedforward control are analyzed in detail, and the time-delay caused by the low-pass filter (LPF) in the voltage filtering circuits and digital control are summarized. In order to reduce the time-delay effect on the performance of the feedforward control, a voltage feedforward control strategy with time-delay compensation is proposed, in which, a leading correction of the feedforward voltage is used. The optimal leading step used in this strategy is derived from analyzing the phase-frequency characteristics of a LPF and the implementation of digital control. By using the optimal leading step, the delay in the feedforward path can be further counteracted so that the performance of the feedforward control in terms of suppressing the influence of grid voltage distortion on the converter output current can be improved. The validity of the proposed method is verified through simulation and experiment results.

A Study on Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-phase Grid-connected Inverters (단상 계통연계형 인버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구)

  • Hwang, Seon-Hwan;Hwang, Young-Gi;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.68-76
    • /
    • 2014
  • This paper presents an offset error compensation algorithm for the accurate phase angle of the grid voltage in single-phase grid-connected inverters. The offset error generated from the grid voltage measurement process cause the fundamental harmonic component with grid frequency in the synchronous reference frame phase lock loop (PLL). As a result, the grid angle is distorted and the power quality in power systems is degraded. In addition, the dq-axis currents in the synchronous reference frame and phase current have the dc component, first and second order ripples compared with the grid frequency under the distorted grid angle. In this paper, the effects of the offset and scaling errors are analyzed based on the synchronous reference frame PLL. Particularly, the offset error can be estimated from the integrator output of the synchronous reference frame PLL and compensated by using proportional-integral controller. Moreover, the RMS (Root Mean Square) function is proposed to detect the offset error component. The effectiveness of the proposed algorithm is verified through simulation and experiment results.