• Title/Summary/Keyword: Testing chamber

Search Result 221, Processing Time 0.034 seconds

Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite (이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구)

  • Lee, Jun-Bong;Park, Jong-Duk;Kwon, Su-Mi;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

Preliminary study on absorption characteristic of a human body according to the amount of clothing worn for developing standard test dummy (표준더미 개발을 위한 착의량에 따른 인체의 흡음특성 기초연구)

  • Kim, Yong-Hee;Lee, Sung-Chan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.254-260
    • /
    • 2017
  • The purpose of this study is to evaluate the sound absorption characteristics of a human body according to the amount of clothing worn by using reverberation method measurement method for developing standard test dummy, which can be used for testing absorption of occupied audience chair. Test method was based on the previous study (Conti et al., 2004), each experiment is conducted in the reverberation room and a subject wearing clothes is standing in that chamber. In this experiment, the sound absorption area of each frequency band according to the wearing of various material clothing was measured. As a result of measurements, the average sound absorption area of the whole frequency band was $0.25m^2-0.48m^2$ in case of a subject not wearing outer clothes, and $0.38m^2-0.98m^2$ in case of wearing of outerwear. Polyester tops by showing the maximum value, the highest characteristics in the 800 Hz to 1 kHz band among the rest of fiber materials. The outer jacket made of the wool and cotton materials show a higher absorption area as the frequency increases to the higher frequency band. The change of the sound absorption area according to the clothing amount was divided by the thermal resistance (clo) of the worn clothes and the weight per body surface area.

The Study on the Slurry Wear Behavior of Rubber Vulcanizates (고무 소재의 슬러리 마모 거동에 관한 연구)

  • Chung, Kyung-Ho;Hong, Young-Keun;Park, Moon-Soo
    • Elastomers and Composites
    • /
    • v.46 no.1
    • /
    • pp.70-77
    • /
    • 2011
  • A new piece of test equipment, the slurry wear tester (SWT), was proposed in this study to evaluate the wear behavior of rubber vulcanizate in environmental contact with slurry. Natural rubber (NR) and chloroprene rubber (CR) were chosen as the basic matrices to test the slurry wear. The fluids used to fill the chamber of the SWT were 35% HCl and NaCl solution. The Akron abrasion test was used for comparison with SWT. According to the results of the Akron abrasion test, CR vulcanizate abraded more rapidly than NR vulcanizate under same test condition. It was found that the hysteresis of rubber was key factor contribute to the wear behavior. However, the slurry wear rate of the NR and CR vulcanizates did not change significantly, even with changes in the concentration of acid and the immersion time in both HCl and NaCl solutions; the fluid decreased the friction between the abrasive paper and the specimen. It also reduced the heat generated from repeated deformation and wear debris at the surface of the SWT's abrasion arm. Thus, these phenomena affected the wear behavior of rubber vulcanizate and caused different results in the conventional Akron abrasion test. This outcome could have resulted in an incorrect analysis if the slurry wear behavior of the rubber vulcanizate was estimated by the conventional abrasion tests, which are operated under dry conditions.

A COMPARISON OF MASTER APICAL FILE SIZE ACCORDING TO INSTRUMENTATION IN TYPE II ROOT CANAL (제2형 근관의 확대에 따른 최종근관장파일 크기의 비교)

  • Jeong, Eun-Ju;Lee, Dong-Kyun;Baek, Shin-Young;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.435-442
    • /
    • 2008
  • Type II root canal was defined that two canals leave the chamber and merge to form a single canal at short of the apex. The aim of this study was to analyse the master apical file (MAF) size according to various instrumentation techniques in the type II root canal when each canal was enlarged to working length. Eighty mesial roots of molar with ISO #15 initial apical file (IAF) size in type II root canals were randomly divided into four experimental groups with 20 teeth each. According to enlarging instruments, four groups are: K-$FLEXOFILE^{(R)}$ (KF), engine-driven Ni-Ti $P_{RO}T_{APER}{^{(R)}}$ (PT), HERO $Shaper^{(R)}$ (HS), $K^{3\;TM}$ (K3). All canals were enlarged to each working length with ISO #30 size: #30 in KF, F3 in PT, .04/30 in HS, and .06/30 in K3. The master apical file (MAF) size was confirmed by tactile sensation and universal test- ing machine (EZ test, Shimadzu Co., Kyoto, Japan). The mean MAF size was statistically compared using one-way ANOVA and Tukey HSD test at the 0.05 probability level. These results show that the MAF size was appeared one or two sizes larger than the final enlarging instrument when all canal in type II configuration were enlarged to each working length. Therefore, the clinician have to confirm the apical stop once more after instrumentation of type II root canal.

Evaluation of Characteristics in the Reference Gamma Radiation Fields for testing of Personnel Dosimetry Performance (개인선량 평가의 성능검증을 위한 기준급 감마선장의 특성 평가)

  • Oh, Jang-Jin;Cho, Dae-Hyung;Han, Seung-Jae;Na, Seong-Ho;Lee, Dew-Hey;Lee, Byung-Soo;Jun, Jae-Shik;Chai, Ha-Seok;Yi, Chul-Young
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.229-236
    • /
    • 1998
  • In order to establish a testing system for personnel dosimetry performance, the radiation fields from photons, beta particles and neutrons are required, in recent, Korea Institute of Nuclear Safety(KINS) established the reference radation fields except neutrons and tested a variety of their properties. As a result of the test, the reference beams were shown to meet satisfactorily not only the standards of the International Organization for Standardization(ISO), but also the standard levels of the developed countries which are intercomparable with the international traceability. This paper describes the reference beam of gamma radiation. The self-designed and established reference radiation fields were investigated and analyzed by ISO and other international standards. The secondary photon contribution and the beam uniformity of the gamma radiation field were measured and evaluated to fulfill those requirements suggested by the ISO-4037. The measured air kerma rate for the $^{137}$Cs and $^{60}$Co gamma fields was 0.1891 $\sim$ 23.4967 $\mu$Gy/s sand 0.5844 $\sim$ 15.9954 $\mu$Gy/s respectively. The uncertainty with 95 % confidence level of the measured air kerma rate was determined to be less than 2.5 % which is comparable to the international reference gamma radiation fields. It was found that the evaluated air kerma calibration factors of Exradin ionization chamber were in good agreement within 0.9 % and 0.03 % with those given by PTB and NIST, respectively. The gamma radiation fields installed at KINS can maintain traceability systems in Korea, Germany and United State.

  • PDF

An Analysis of a Porous Film Containing $Chamaecyparis$ $obtusa$ Extract (편백나무 추출물을 함유한 다공성 필름 분석)

  • Kim, Kyeong-Yee;Lee, Eun-Kyung
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.4
    • /
    • pp.551-558
    • /
    • 2011
  • This present study was performed to analyze the efficiency and volatility of a porous film containing $Chamaecyparis$ $obtusa$ extract as a method to effectively package food compounds. Phytoncide was contacted the state of gas and showed effective antimicrobial properties. Limonene can be distilled without decomposition as a relatively stable terpene and was one of the extract components. $Chamaecyparis$ $obtusa$ essential oil. The optimal solvent composition was a ratio 5:20:0.3 of T-500:ethanol:hardener to effectively manufacture film containing phytoncide essential oil and the minimum antibacterial concentration was 2%. The films were made under different conditions(A-50LF1, A-25SF2, B-50SF1, C-50LF1, C-25SF2 and D-50SF1) containing phytoncide and the amounts of limonene inside the 1-L reaction chamber depending on storage were measured by gas chromatography-mass selective detention. The results showed that the 25SF2(width, 25 mm; length, 20 cm) revealed more amount of limonene compared with 50LF1(width 50 mm, length 20 cm). We confirmed that the gas emission amount showed a better layer on the film side than on the internal film. An effect of film thickness on phytoncide emissions was observed in that the amounts was less than the expectation for a thicker film at the beginning time, but the emitting amounts increased with increasing storage periods. In the storage testing of various films at $35^{\circ}C$ and 70% humidity for 14 days, 25SF2 showed longer preservation compared with that of 50LF in the case of bread. $C.$ $obtusa$ essential oil is a useful fresh ingredients, hence, analysis of limonene emission kinetics from various film was helpful to develop films with an optimal antimicrobial effect, and will allow application of such films in food packaging systems.

A Study on Comparison of Outdoor Wind Pressure Performance According to Outdoor Exposure and Acceleration Deterioration Methods of Structural Sealants Applied to Curtain Wall (커튼월에 적용된 구조용 실링재의 옥외폭로와 실내복합열화 처리방법에 따른 내풍압성능 비교연구)

  • Jang, Pil Sung;Hong, Soon Gu;Kim, Sung Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.279-287
    • /
    • 2018
  • Sealants are an important element of modern architecture and serve as a building protection against weathering by providing barriers against ingress of moisture, air, and other materials. Exposure to a variety of environments often reduces lifespan due to changes in physical, chemical and mechanical characteristics, and UV, humidity, and temperature expansion are important issues that are directly related to durability. In this study, a combined deterioration test chamber was developed to simulate the environment of the open air as an instrument for verifying the durability of structural sealing materials indoors. In order to replicate special weather conditions, such as yellow dust, acid rain, and contamination by microorganisms, it was deemed impossible to replicate the outdoor environment by 100 %, and the results of the results of the results of the external exposure test of the structural sealant and the combined deterioration testing device. As a result of the displacement test of the outdoor exposure test, it was determined that the sealant was breaking apart and that it would be smooth, and the displacement would be up to three times greater than the initial material value of 1 year. The displacement test results of the combined deterioration test device show the tendency to deteriorate, decreasing the elasticity and tensile characteristics. In the case of denatured silicon, the current 400 cycles have been completed to confirm 12 months of degradation of the external exposure. The deformation of the test specimen cannot be verified with the naked eye, so it is considered that the conditions of the specimen are more stable than the silicon sealant. As a result of the outdoor exposure test, if the combined deterioration test device is structured and proposed in the relevant guidance or specification, the anticipated lifespan of 12 months in the actual use environment can be verified indoors and below 3 months later, economically.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Swelling and Mechanical Property Change of Shale and Sandstone in Supercritical CO2 (초임계 CO2에 의한 셰일 및 사암의 물성변화 및 스웰링에 관한 연구)

  • Choi, Chae-Soon;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.22 no.4
    • /
    • pp.266-275
    • /
    • 2012
  • In this study, a method is devised to implement a supercritical $CO_2$ ($scCO_2$) injection environment on a laboratory scale and to investigate the effects of $scCO_2$ on the properties of rock specimens. Specimens of shale and sandstone normally constituting the cap rock and reservoir rock, respectively, were kept in a laboratory reactor chamber with $scCO_2$ for two weeks. From this stage, a chemical reaction between rock surface and the $scCO_2$ was induced. The effect of saline water was also investigated by comparing three conditions ($scCO_2$-rock, $scCO_2-H_2O$-rock and $scCO_2$-brine(1M)-rock). Finally, we checked the changes in the properties before and after the reaction by destructive and nondestructive testing procedures. The swelling of shale was a main concern in this case. The experimental results suggested that $scCO_2$ has a greater effect on the swelling of the shale than pure water and brine. It was also observed that the largest swelling displacement of shale occurred after a reaction with the $H_2O-scCO_2$ solution. The results of a series of the destructive and nondestructive tests indicate that although each of the property changes of the rock differed depending on the reaction conditions, the $H_2O-scCO_2$ solution had the greatest effect. In this study, shale was highly sensitive to the reaction conditions. These results provide fundamental information pertaining to the stability of $CO_2$ storage sites due to physical and chemical reactions between the rocks in these sites and $scCO_2$.

Mechanical Property Evaluation of Dielectric Thin Films for Flexible Displays using Organic Nano-Support-Layer (유기 나노 보강층을 활용한 유연 디스플레이용 절연막의 기계적 물성 평가)

  • Oh, Seung Jin;Ma, Boo Soo;Yang, Chanhee;Song, Myoung;Kim, Taek-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.3
    • /
    • pp.33-38
    • /
    • 2021
  • Recently, rollable and foldable displays are attracting great attention in the flexible display market due to their excellent form factor. To predict and prevent the mechanical failure of the display panels, it is essential to accurately understand the mechanical properties of brittle SiNx thin films, which have been used as an insulating film in flexible displays. In this study, tensile properties of the ~130 nm- and ~320 nm-thick SiNx thin films were successfully measured by coating a ~190 nm-thick organic nano-support-layer (PMMA, PS, P3HT) on the fragile SiNx thin films and stretching the films as a bilayer state. Young's modulus values of the ~130 nm and ~320 nm SiNx thin films fabricated through the controlled chamber pressure and deposition power (A: 1250 mTorr, 450 W/B: 1000 mTorr, 600 W/C: 750 mTorr, 700 W) were calculated as A: 76.6±3.5, B: 85.8±4.6, C: 117.4±6.5 GPa and A: 100.1±12.9, B: 117.9±9.7, C: 159.6 GPa, respectively. As a result, Young's modulus of ~320 nm SiNx thin films fabricated through the same deposition condition increased compared to the ~130 nm SiNx thin films. The tensile testing method using the organic nano-support-layer was effective in the precise measurement of the mechanical properties of the brittle thin films. The method developed in this study can contribute to the robust design of the rollable and foldable displays by enabling quantitative measurement of mechanical properties of fragile thin films for flexible displays.