태양광발전 계통연계 실증시험장 구축에 관한 연구 (The study on construction of the practical testing ground of grid-connected photovoltaic system)

  • 김의환;장주연
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • Currently the variety of governmental business support and research for supplying solar energy have been actively progressed. As of now, however, There are no practical testing infrastructures of grid-connected photovoltaic system which test performance of solar power facility in domestic. Therefore, in KEPRI, there is in progress construction of practical testing ground of 500 kW class grid-connected PV System for developing the evaluation of the performance technology including the Module, PCS, and etc, that is the important instrument of the PV System, in Gochang area. It analyzed the site creation work for constructing the practical testing ground and new construction of control room and the unit standards, specifications and capacity of required equipment. For the system detailed design, configuration, instrument-specific parameters established, power generation predictions of Array Type and the components of testing ground are needed to build.

  • PDF

Design and Analysis of an Accelerated Life Test for Magnetic Contactors

  • Ryu, Haeng-Soo;Park, Sang-Yong;Han, Gyu-Hwan;Kwon, Young-Il;Yoon, Nam-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.188-193
    • /
    • 2007
  • Magnetic contactors (MCs) are widely used in industrial equipment such as elevators, cranes and factory control rooms in order to close and open the control circuits. The reliability of MCs mainly depend on mechanical durability and international standards such as IEC 60947-4-1, which stipulates the testing method for MCs. Testing time, however, is so long in usual cases that a method of reducing testing time is required. Therefore, a temperature and voltage-accelerated life testing (ALT) method has been developed to reduce the testing time in this work. The accelerated life test data are analyzed and acceleration factors (AFs) are provided.

S-Z 중성선 전력 케이블의 개발 (DEVELOPMENT OF S-Z STRANDED NEUTRAL POWER CABLE)

  • 김종원;백흠수;최영훈;최명규;김선국;김종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1296-1298
    • /
    • 1995
  • This paper presents the power cable with the concentric neutral wires of S-Z stranding. This type Cables, 22.9KV CN/CV Cables used in the distribution systems have been developed in order to improve bend, bend after torsion and tension charateristics. We have designed and made S-Z stranding machine, testing equipment etc., and have established the manufacturing technology of the equipment and the testing technology.

  • PDF

원자력 발전소용 Tilting Check Valve의 특성실험 (II) (Characterisic Experiment of Tilting Check Valve for Nuclear Power Plant(II))

  • 염만오
    • 대한기계학회논문집B
    • /
    • 제22권6호
    • /
    • pp.803-812
    • /
    • 1998
  • In this study, testing equipment with which several kinds of valves can be tested was composed. Two kinds of tilting check valves and a swing check valve were tested to analyze their dynamic characteristics. The results of the experiment showed that the tilting check valves protected the pump but that the swing check valve could not protect the pump when the reverse flow rate was high. Also the dynamic equation of the tilting check valve was formulated and simulated using system characteristic constant t$_{c}$ and one method of predicting t$_{c}$ by comparing the results of the simulation with the results of the experiment was proposed.sed.

자외선 열화에 의한 실리콘고무의 열화 특성 연구를 위한 열화장치 및 시험방법의 개발 (Development of Aging Equipment and Testing Method for UV Effected Degradation Characteristics of Silicone Rubber)

  • 이정헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.93-96
    • /
    • 2007
  • In this paper, the testing equipment for evaluating aging characteristics of outdoor silicone rubber insulator resulting from the environmental aging effect with regards to sunlight(UV) was developed. Influence of sunlight effect aging is seriously increase due to destruction of ozone layer which is occurred by consumption of fossil fuel. For this purpose, silicone rubber was aged under the artificial sunlight by exposure of xenon lamp radiation in the accelerating aging chamber and various test and analysis were performed such as breakdown strength, contact angle. And FT-IR analysis has been followed.

  • PDF

군 환경시험규격 현실화를 위한 한반도 자연환경 조건분석 (A Study on The Korean Climatic Condition for The Military Environmental Testing Specification.)

  • 이관훈;송병석;홍원식;강보철;염대원;이도희;김준원;금종주
    • 한국군사과학기술학회지
    • /
    • 제4권2호
    • /
    • pp.70-83
    • /
    • 2001
  • The required standards for environmental tests for communication and electronic equipment used currently in the army are not standards into which the Korean climate and use environment are taken into consideration. But the environmental testing standards of the U.S. army at the time of its establishment(MIL-STD-810) “A” version has been used without taking into consideration the Korean domestic situation and conditions by simply translating the US standards. Adherence to these standards may limit the ability to supply materials in case of emergency since the increase in the manufacturing costs according to excessively strict standards induces an increase in the acquisition cost of military equipment, unnecessarily high maintenance and repair expenses are consumed, and stocks of parts for the military use have to be retained at all times.

  • PDF

순시전원품질 변화에 딱른 엘리베이터의 오동작에 관한 분석 (The analysis for malfunction of elevator equipment by instantaneous power quality)

  • 김기현;김종민;이건호;김선구;윤상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.34-36
    • /
    • 2006
  • The number of confine-disease of elevator increases every year and then sudden rise, sudden stop, error of level indication, stand; those can bring to uneasiness of elevator passenger and malfunction accidents related life accident are increasing. For confirmation those malfunction accident, we are measuring and analyzing power quality(Sag, Interruption, Harmonic) of the actual site and evaluated the performance for stop and stating by testing the two imitation test equipment with EN12016(2004) standard level. This paper will be used data of the analysis for mutual relation between Power Quality and malfunction and fault of elevator.

  • PDF

의학용 초음파검사기에 의한 MoSi2의 미소결함 탐상 (A Study on Detection of Small Defects for MoSi2 by Medical Ultrasonic Testing)

  • 남궁재관;김유철
    • 한국안전학회지
    • /
    • 제10권4호
    • /
    • pp.9-12
    • /
    • 1995
  • Detection of small defects by medical ultrasonic testing when the thermal sprayed coating by $MoSi_2$ on the metal is done. The defects may occur at the bonded surface. So, the detecting method of the defects by non-destructive in spection is desired. Here, in order to examine the possibility of the detection of the small defects by the ultrasonic. The electronic scanning ultrasonic equipment using an array probe developed as the medical ultrasonic diagnostic equipment is applied for the detection of the metal material defects. It's validity is investigated.

  • PDF

강자성체 평판의 자속 누설 탐상 비파괴 실험 및 수치해석 (Non-destructive Testing and Numerical Analysis for Ferromagnetic Plates using Magnetic Flux Leakage Method)

  • 김신;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.126-128
    • /
    • 2001
  • In this paper, Magnetic Flux Leakage(MFL) method is used to detect surface defect in ferromagnetic plate. Surface defects are created on the SM 45C ferromagnetic plate and magnetizing equipment is composed to perform MFL nondestructive testing. The length and width of defect is twice the thickness of ferromagnetic plate, and defects with different depths are made artificially for the experiment. Also, NdFeB magnet in magnetizing equipment is used to make magnetic flux. This paper shows that it is possibile to detect 10% defect and to analyze numerically for any defect using MFL method.

  • PDF

해머형 비파괴시험장비를 이용한 콘크리트의 압축강도평가에 관한 연구 (A Study on the Evaluation of Compressive Strength of Concrete Using Hammer Type Nondestructive Testing Equipment)

  • 김호;김규용;황의철;손민재;백재욱;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.65-66
    • /
    • 2018
  • As a result of this study, it was possible to derive the compressive strength curves of ordinary to ultra high strength concrete using the hammer type non - destructive testing equipment. In order to obtain reliable results, it is necessary to construct additional data. In addition, if reliability is ensured through construction site evaluation, it is considered that the application is possible on construction site.