• Title/Summary/Keyword: Testing & Evaluation Method

Search Result 1,052, Processing Time 0.028 seconds

Math Creative Problem Solving Ability Test for Identification of the Mathematically Gifted Middle School Students (중학교 수학 영재 판별을 위한 수학 창의적 문제해결력 검사 개발)

  • Cho, Seok-Hee;Hwang, Dong-Jou
    • Journal of Gifted/Talented Education
    • /
    • v.17 no.1
    • /
    • pp.1-26
    • /
    • 2007
  • The purpose of this study was to develop a math test for identification of the mathematically gifted on the basis of their math creative problem solving ability and to evaluate the goodness of the test. Especially, testing reliability and validity of scoring method on the basis of fluency only for evaluation of math creative problem solving ability was one of the main purposes. Ten closed math problems and 5 open math problems were developed requiring math thinking abilities such as intuitive insight, organization of information, inductive and deductive reasoning, generalization and application, and reflective thinking. The 10 closed math test items of Type I and the 5 open math test items of Type II were administered to 1,032 Grade 7 students who were recommended by their teachers as candidates for gifted education programs. Students' responses were scored by math teachers. Their responses were analyzed by BIGSTEPS and 1 parameter model of item analyses technique. The item analyses revealed that the problems were good in reliability, validity, item difficulty and item discriminating power even when creativity was scored based on the single criteria of fluency. This also confirmed that the open problems which are less-defined, less-structured and non-entrenched were good in measuring math creative problem solving ability of the candidates for math gifted education programs. In addition, it was found that the math creative problem solving tests discriminated applicants for the two different gifted educational institutions.

Testing The Healing Environment Conditions for Nurses with two Independent Variables: Visibility Enhancement along with Shortening the Walking Distance of the Nurses to Patient - Focused on LogWare stop sequence and space syntax for U-Shape, L- Shape and I-Shape NS-

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.19-26
    • /
    • 2015
  • Purpose: Maximizing human comfort in design of medical environments depends immensely on specialized architects particularly critical care design; the study proposes Evidence-Based Design as an apparent analog to Evidence-Based Medicine. Healthcare facility designs are substantially based on the findings of study in an effort to design environments that augment care by improving patient safety and being therapeutic. On SPSS (Statistical Package for Social Science) t-test is applied to simulate two independent variables of PDR (Pre Design-Research) and POE (Post- Occupancy Evaluation). PDR is conducted on relatively new hospital Hallym University Dongtan Sacred Heart Hospital to analyse visibility from researchers' point of view, here the ICU is arranged in I-Shape. POE is applied on Dongguk University Ilsan Hospital to simulate walking on LogWare where two NS are designed based on L- Shape and Seoul St. Mary's Hospital, The Catholic University of Korea where five NS are functional for ICU Intensive Care Unit, Surgical Intensive Care Unit (SICU), Medical Intensive Care Unit (MICU), Critical Care Unit (CCU), Korean Oriental Medical Care Unit which are mostly arranged in U-Shape, and walking pattern is recognized to be in a zigzag path. Method: T-Test is applied on two dependent communication variables: walkability and visibility, with confidence interval of 95%. This study systematically analyses the Nurse Station (NS) typo-morphology, and simulates nurse horizontal circulation, by computing round route visits to patient's bed, then estimating minimum round route on LogWare stop sequence software. The visual connectivity is measured on depth map graphs. Hence the aim is to reduce staff stress and fatigue for better patients care by minimizing staff horizontal travel time and to facilitate nurse walk path and support space distribution by increasing effectiveness in delivering care. Result: Applying visibility graph and isovist field on space syntax on I- Shape, L- Shape and U- Shape ICU (SICU, MICU and CCU) configuration, I-shape facilitated 20% more patients in linear view as they stir to rise from their beds from nurse station compared to U-shape. In conclusion, it was proved that U-Shape supply minimum walking and maximum visibility; and L shape provides just visibility as the nurse is at pivot. I shape provides panoramic view from the Nurse Station but very rigorous walking.

A Study on the Specialization of Private Security Industry in Korea through the Japanese Private Security Certification System (일본 민간경비원 검정제도 연구를 통한 한국 민간경비산업 전문화 방안)

  • Lee, Chi Young
    • Korean Security Journal
    • /
    • no.59
    • /
    • pp.71-90
    • /
    • 2019
  • As the demand for national security and national safety is gradually increasing in accordance with the trend of the times and social environment, and the use of private areas for effective prevention and supply required for the demand for safety services, this paper analyzed the Japanese private security testing system for the introduction of the Korea security certification system as a way to secure expertise in the private security industry and drew the following conclusion. First, certificate segmentation should be carried out according to the clearly divided field and scope of the expense operation. Second, it is necessary to distinguish the qualification of the private security qualification according to the level. Third, it is necessary to utilize the combined evaluation method through the departmental and practical tests. Fourth, an assessment should be made through the link between departments and practical subjects. Fifth, the diversity of the acquisition methods should be placed to ensure the gainer's accessibility. Finally, the use of professional and visible use of professional personnel should be achieved through benefit assessment for those who are qualified for

A Study on Clinical Feasibility and Practical Strategies for Dental Hygiene Process (ADPIE) (치위생과정(ADPIE)의 임상적용 가능성과 실천방안 모색)

  • Lee, Joo-Young;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.433-441
    • /
    • 2014
  • This study was aimed to analyze factors affecting intention on clinical application by task autonomy of dental hygienists, expected effect and obstructive factor on clinical application of assessment, dental hygiene diagnosis, planning, implementation, and evaluation (ADPIE). Meanwhile, it proved mediating effects of "attitude toward ADPIE" when it came to "intention on clinical application". The data was collected from 237 dental personnel in capital region from March 28, 2014 to May 2, 2014. To analyze the suitability of a theoretical model and hypothesis testing, SPSS 21.0 and AMOS 18.0 program were used. The theoretical model was accepted as it resulted in ${\chi}^2=421.67$ while showing goodness of fit index=0.858, comparative fit index=0.915, Tucker-Lewis index=0.896, root mean square residual=0.039, and root mean square error of approximation=0.099. The result showed "task autonomy of dental hygienists (${\beta}=0.398$, p<0.05)" and "expected effect on ADPIE (${\beta}=0.363$, p<0.01)" had a positive effect on "attitude toward ADPIE". Also, "attitude toward ADPIE" had a positive effect on "intention on clinical application". In addition, "task autonomy of dental hygienists" and "expected effect on ADPIE" had an indirect influence on "intention on clinical application" via such intermediary as "attitude toward ADPIE". According to the above results, the task autonomy of dental hygienists, expected effect on ADPIE, and attitude toward ADPIE were confirmed to be significant factors when it came to the intention on its clinical application. Therefore in order to settle ADPIE in the clinical practice, improvement of task autonomy for dental hygienists as well as their expectation and attitude on ADPIE must be promoted.

Assessment of Surface Boundary Conditions for Predicting Ground Temperature Distribution (지중온도 변화 예측을 위한 지표면 경계조건 검토)

  • Jang, Changkyu;Choi, Changho;Lee, Chulho;Lee, Jangguen
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.75-84
    • /
    • 2013
  • Soil freezing is a phenomenon arising due to temperature difference between atmosphere and ground, and physical properties of soils vary upon the phase change of soil void from liquid to solid (ice). A heat-transfer mechanism for this case can be explained by the conduction in soil layers and the convection on ground surface. Accordingly, the evaluation of proper thermal properties of soils and the convective condition of ground surface is an important task for understanding freezing phenomenon. To describe convection on ground surface, simplified coefficient methods can be applied to deal with various conditions, such as atmospheric temperature, surface vegetation conditions, and soil constituents. In this study, two methods such as n-factor and convection coefficient for the convective ground surface boundary were applied within a commercial numerical program (TEMP/W) for modeling soil freezing phenomenon. Furthermore, the numerical results were compared to laboratory testing results. In the series of the comparison results, the convection coefficient is more appropriate than n-factor method to model the convective boundary condition.

Evaluation of the change of lower lip sensation after inferior alveolar nerve block by using the electric pulp tester (하치조신경 마취 후 전기치수검사기(Electric pulp tester)를 이용한 하순부 감각 변화 평가)

  • Ku, Myong-Suk;Kim, Jin-Wook;Jeon, Young-Hoon;Kwon, Tae-Geon;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.6
    • /
    • pp.464-469
    • /
    • 2011
  • Introduction: As dental implant surgery is becoming increasingly popular, it has become one of the causes for the hypesthesia of the inferior alveolar nerve, along with other surgical procedures, such as a third molar extraction. In addition, it tends to cause legal problems between the operator and patient. Therefore, there must be a proper method that is reliable, objective and economical to assess the nerve impairment. For this reason, an attempt was made to use an Electric Pulp Tester to assess inferior alveolar nerve block anesthesia. Materials and Methods: Thirty patients were tested. Electric pulp testing of the lower jaw skin was performed at the three different times, before anesthesia, at the onset of sensory changes and after 15 minutes waiting from the onset, and on the 10 points of the chin, which produced 10 sections on the skin area. Results: Twenty seven patients (90%) could feel the electric stimulus on the chin at all 10 points before local anesthesia and the scores represent the statistical differences between the right and left points except R4 and L4. After anesthesia, the difference between the right and left points (L3-R3, L4-R4, L5-R5) increased significantly with time but two points (L2, R2) showed no significant difference. The scores on the left chin (L3, L4, L5) increased, whereas the other points (R1-R5, L1, L2) showed no significant differences. Conclusion: This study highlights the potential clinical use of an electric pulp tester for an assessment of inferior alveolar nerve impairment.

A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application (광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구)

  • Park, Ji Koon;Noh, Si Cheol;Choi, Il Hong;Jung, Bong Jae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.423-428
    • /
    • 2014
  • Digital X-ray imaging devices using a TFT based flat panel array has been used in medical field. But, recently, lots of research on the photon counting sensor has been reported. In this study, we evaluated the physical properties of the photoconductor by suggesting the standard and testing method for quantitative performance evaluation of photon counting x-ray imaging sensor. First, we measured the leakage current and the sensitivity of photon counting x-ray imaging sensor and we evaluated the characteristic of rising time for determining the signal shaping time. In addition, the set-up study was conducted on the basis of the IEC 62220-1-2 recommendations to define the number of incident photons per unit area. And the efficiency of the charge collection was also evaluated. As a result, the characteristic was measured as $200pA/mm^2$ of the leakage current, $7{\mu}C/cm^2R $ of the X-ray sensitivity, and $0.765{\mu}s$ of the rising time.

Evaluation of Field Nonlinear Modulus of Subgrnde Soils Using Repetitive Static Plate Bearing Load Test (반복식 평판재하시험을 이용한 노상토의 현장 변형계수 평가)

  • Kim Dong-Soo;Seo Won-Seok;Kweon Gi-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.67-79
    • /
    • 2005
  • The field plate load test has a good potential for determining modulus since it measures both plate pressure and settlement. Conventionally the modulus has been assumed to be a constant secant value defined from the settlement of the plate at a given load intensity. A constant modulus (modulus of subgrade reaction, k), however, may not be a representative value of subgrade soil under working load. Field strain(o. stress)-dependent modulus characteristics of subgrade soils, at relatively low to intermediate strains, are important in the pavement design. In this study, the field strain dependent moduli of subgrade soils were obtained using cyclic plate load test. Testing procedure and data reduction method are proposed. The field crosshole and laboratory resonant column tests were also performed to determine field nonlinear modulus at $0.001\%\;to\;0.1\%$ strains, and the modulus values and nonlinear trends are compared to those obtained by cyclic plate load tests. Both modulus values match relatively well when the different state of stress between two tests was considered, and the applicability of field cyclic plate load test for determining nonlinear modulus values of subgrade soils is verified.

Durability Evaluation on the Air-Braking Release Failure Proof Valve of Cargo Train (화물열차 공기제동 완해불량 방지 밸브의 내구성 평가)

  • Lee, Jun-Ku;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.32-38
    • /
    • 2020
  • Cargo train braking uses the pressure changes in the air braking pipe to operate the braking tightening and releasing service repeatedly. Air-braking release failure means partial braking caused by a failure of the variable load valve after the driver handling the brake release. This phenomenon causes wheel flaws while driving a wagon, resulting in wheel breakage or train derailment. This study developed the air-braking release failure proof valve considering the technical requirements of the railway operation corporations. In addition, a durability test of the valve was carried out using a braking performance simulator, and its operating performance was evaluated from the pneumatic history under cyclic braking conditions. The warranty life of this valve was assessed by performing 160,000 cycles of testing of 12 prototypes in accordance with the zero-failure test method, considering the number of braking cycles while driving the wagon. During the durability test, the pneumatic input time, output time, and release velocity were almost constant. The warranty life of this valve was 59,860 times the 95% confidence level, which means that it can be operated without trouble for four years when the valve is installed in the bogie of the wagon.

Assessment of In Vitro Assay System for Thyroid Hormone Disruptors Using Rat Pituitary GH3 Cells

  • Kim, Hee-Jin;Park, Hae-Young;Kim, Jeong-A;Kang, Il-Hyun;Kim, Tae-Sung;Han, Soon-Young;Kang, Tae-Seok;Park, Kui-Lea;Kim, Hyung-Sik
    • Toxicological Research
    • /
    • v.22 no.4
    • /
    • pp.307-313
    • /
    • 2006
  • The development of in vitro assays has been recommended to screening and testing the potential endocrine disruptors (EDs). These assay systems focus only on identifying the estrogenic or antiestrogenic activity of EDs, whereas a few studies have been carried out to screen the thyroid hormone (TH) disruptors. The aim of this study was to evaluate a test system to detect TH disruptors using rat pituitary tumor $GH_3$ cells. The test system is based on the TH-dependent increase in growth rate. As expected, L-3,5,3-triiodothyronine ($(T_3)$ markedly induced a morphological change in $GH_3$ cells from flattened fibroblastic types to rounded or spindle-shaped types. $T_3$ stimulated $GH_3$ cell growth in a dose-dependent manner with the maximum growth-stimulating effect being observed at a concentration $1{\times}10^9M$. In addition, $T_3$ increased the release of growth hormone and prolactin into the medium of the $GH_3$ cells culture. Using this assay system, the TH-disrupting activities of bisphenol A (BPA) and its related compounds were examined. BPA, dimethy/bisphenol A (DMBPA), and TCI-EP significantly enhanced the growth of $GH_3$ cells in the range of $1{\times}10^{-5}M\;to\;1{\times}10^{-6}M$ concentrations. In conclusion, this in vitro assay system might be useful for identifying potential TH disruptors. However, this method will require further evaluation and standardization before it can be used as a broad-based screening tool.