• Title/Summary/Keyword: Test module

Search Result 1,585, Processing Time 0.028 seconds

Understanding and Designing Teachable Agent (교수가능 에이전트(Teachable Agent)의 개념적 이해와 설계방안)

  • 김성일;김원식;윤미선;소연희;권은주;최정선;김문숙;이명진;박태진
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.13-21
    • /
    • 2003
  • This study presents a design of Teachable Agent(TA) and its theoretical background. TA is an intelligent agent to which students as tutors teach, pose questions, and provide feedbacks using a concept map. TA consists of four independent Modules, Teach Module, Q&A Module, Test Module, and Resource Module. In Teach Module, students teach TA by constructing concept map. In Q&A Module, both students and TA ask questions and answer questions each other through an interactive window. To assess TA's knowledge and provide feedback to students, Test Module consists of a set of predetermined questions which TA should pass. From Resource Module, students can search and look up important information to teach, ask questions, and provide feedbacks whenever they want. It is expected that TA should provide student tutors with an active role in learning and positive attitude toward the subject matter by enhancing their cognition as well as motivation.

  • PDF

Moisture Diffusion Analysis for Bendable Electronic Module Under Autoclave Test Condition (유연성 전자모듈에 대한 오토클레이브 시험조건에서의 습기확산해석)

  • Han, Chang-Woon;Oh, Chul-Min;Hong, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.523-528
    • /
    • 2012
  • A bendable electronic module is developed for a mobile application by using a low-cost roll-to-roll manufacturing process. In the module, a thin silicon chip is embedded in a polymer-based encapsulating adhesive between flexible copper clad polyimide layers. A set of tests are conducted for the purpose of qualification: thermal shock, high temperature storage, and autoclave tests. During the autoclave test, delamination occurs at many places within the module layers. To investigate the failure mechanism, moisture diffusion analysis is conducted for the interior of the module under the autoclave test condition. For the analysis, the hygroscopic characteristics of the encapsulating materials are experimentally determined. Analysis results indicate the moisture saturation process in the interior of the module under the autoclave test condition.

Usability Test Analysis on Integrated Automotive Cockpit Module System (자동차 전장 통합 모듈 시스템에서의 사용성 평가)

  • 홍성만;박범
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2003.11a
    • /
    • pp.237-245
    • /
    • 2003
  • More and more many people show a keen interest in the ergonomics application car. One of the recent trends of cockpit development is to integrate fore part of whole cockpit and compartment. The goal of this study is to develop and Analysis of User's Convenience a cockpit prototype based on the design guide of cockpit integration module. The process of this study has been followed analyzing development trend of next generation Automotive cockpit, extracting the design factor needed to making integration module and laying down the design guide of cockpit integration module. Finally, this study is indicate an instance that evaluation of utilization with Integrated Automotive Cockpit Module System.

  • PDF

Usability Test Analysis for Design on Integrated Automotive Cockpit Module System (자동차 전장 통합 모듈 시스템 설계를 위한 사용성 평가)

  • 홍성만;박범;이성용
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.4
    • /
    • pp.157-167
    • /
    • 2003
  • More and more many people show a keen interest in the ergonomics application car. One of the recent trends of cockpit development is to integrate fore part of whole cockpit and compartment. The goal of this study is to develop and Analysis of User's Convenience a cockpit prototype based on the design guide of cockpit integration module. The process of this study has been followed analyzing development trend of next generation Automotive cockpit, extracting the design factor needed to making integration module and laying down the design guide of cockpit integration module. Finally, this study is indicate an instance that evaluation of utilization with Integrated Automotive Cockpit Module System.

Suggestion of PV Module Test Methods Based on Weathering Monitoring (기후데이터 분석을 통한 태양광모듈의 내구성 평가 기준 제안)

  • Kim, Kyungsoo;Yun, Jaeho
    • Current Photovoltaic Research
    • /
    • v.7 no.2
    • /
    • pp.46-50
    • /
    • 2019
  • The photovoltaic (PV) system consists of solar cells, solar modules, inverters and peripherals. The related evaluation and certification are proceeding as standards published by the IEC (International Electrotechnical Commission) TC (Technical Committee) 82. In particular, PV module is a component that requires stable durability over 20 years, and evaluation in various external environments is very important. Currently, IEC 61215-based standards are being tested, but temperature, humidity, wind and solar radiation conditions are not considered in all areas. For this reason, various types of defects may occur depending on the installation area of the same photovoltaic module. In particular, the domestic climate (South Korea) is moderate. The various test methods proposed by IEC 61215 are appropriate, excessive, or insufficient, depending on environmental condition. In this paper, we analyze the climate data collection for one year to understand the vulnerability of this test method of PV modules. Through this, we propose a test method for PV module suitable for domestic climatic conditions and also propose a technical consideration for installation and design of PV system.

A Study on the Mechanical Reliability of Large-area Bi-facial Glass-to-glass Photovoltaic Modules (대면적 양면 태양광 모듈의 기계적 신뢰성 연구)

  • Yohan, Noh;Jangwon, Yoo;Jaehyeong, Lee
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.111-115
    • /
    • 2022
  • For the high efficiency of the photovoltaic module, a high-output solar cell, which is the basis of photovoltaic power generation, is required. As the light receiving area of the solar cell increases, the light receiving area of the photovoltaic module also increases. Accordingly, recent trend is to use large-area solar cells such as M6 and M8 instead of M2-based solar cells for manufacturing the photovoltaic module and a study on the mechanical stiffness of the module with increased size is required. In this study, a mechanical load test corresponding to IEC-61215 was performed among the reliability tests of large-area photovoltaic modules. In order to confirm the degree to which the mechanical load test affects the photovoltaic module, the output and EL images were checked by sequentially increasing the pressure by 600 Pa at a pressure of 2400 Pa. Also, factors such as output and efficiency of large-area photovoltaic modules were verified through mechanical load testing of actual large-area photovoltaic modules and the rate of change was very small at 1%.

Current-Voltage Measurement Behavior of the CIGS Solar Module through the Evaluation of KS C 8562 Standard (KS C 8562 평가를 통한 CIGS 태양광모듈의 출력 거동 분석)

  • Kyung Soo Kim
    • Current Photovoltaic Research
    • /
    • v.12 no.2
    • /
    • pp.41-47
    • /
    • 2024
  • CIGS solar cells are thin film solar cells that have excellent light absorption coefficient and can be manufactured with high efficiency through the use of low materials. In Korea, they must pass KS certification for home and commercial installation. KS C 8562 is a standard for evaluating the durability of CIGS and thin film amorphous silicon solar modules and deals with contents such as light, temperature, humidity, and mechanical durability. Unlike general crystalline silicon solar modules, the CIGS solar module has a different behavior of output change through these environmental tests, so if it shows 90% or more of the rated output suggested by the manufacturer after the final test, it is judged to be a suitable product. In this paper, the output before and after individual tests was measured through the test method of KS C 8562 to observe the output change and to discover the vulnerabilities of the CIGS solar module when exposed to various environments. Through this, it was confirmed that humidity exposure was the most vulnerable and that it had output recovery characteristics for light (visible light and ultraviolet rays). This study attempted to present the output behavior characteristics and data of the CIGS module at the time when the high efficiency thin film photovoltaic module market is expected to be created in the future.

The Status and Analysis of PV Module's Certificate (결정질 태양전지모듈 인증시험 현황 및 분석)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.55-55
    • /
    • 2009
  • In this paper, we introduce the status of certificate test on crystalline silicon photovoltaic, module in Korea. Up to 5. 2009, about 200 models have passed certificate test under KS C IEC61215 standard. Most products are from Korea, Japan, China. And some are from USA, German and Taiwan. A few environmental test items' results and standard test methods will be discussed. The detail discussion will be shown in the following paper.

  • PDF

Imaging System Wavefront Analysis Using Ronchi Test

  • Lee, Sunwoo;Park, Woojin;Yu, Joonkyu;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.56.2-56.2
    • /
    • 2018
  • Ronchi test is an optical test to check the quality of an imaging system. Wavefront of the optical system can be obtained from the Ronchi patterns. In this poster, we present the Ronchi test module and the optical quality evaluation results. The test module consists of a light source, a pinhole, a beam splitter, a Ronchi ruling and a flat mirror. The test module can be simply adapted to any optical systems. We compare measured surface data for both aluminum and glass parabolic mirrors by analyzing the Ronchi patterns.

  • PDF

Study on the RF-Swithch for Mobile Communication (이동통신용 RF-Switch 개발에 관한연구)

  • 이재영
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.4 no.2
    • /
    • pp.79-83
    • /
    • 1997
  • 본 연구에서는 휴대용 전화기 및 무선 LAN 의 핵심부품인 RF-Switch Module의 초소형화 설계기술, 표면실장기술, 고주파설계기술, 소형화 SMD기술, Test 기술 및 RF-Switch Module 활용기술 등을 개발하였으며 RF-Switch Module의 설계기반 마련 및 대외 경쟁력 있는 RF-Switch Module의 초소형화 기술을 확보하였다.