• Title/Summary/Keyword: Test method

Search Result 32,296, Processing Time 0.057 seconds

A Study on the Standard Criteria of Solid Particle Separation Test for Marine Centrifugal Purifier (선박용 정유기 고형분 분리 성능시험 규격기준에 관한 연구)

  • Jeong, Sang-Hu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.8
    • /
    • pp.1028-1034
    • /
    • 2007
  • In order to establish a criteria of solid particle separation performance test on marine centrifugal purifier at factory acceptance test, an investigation had been done on criteria of test standards, regulations and test specifications of purifier manufactures. KS V 7836, fuel oil and lubricating oil purifiers for marine use-centrifugal type, the criteria of solid particle separation is studied in the point of reality, restricts and analysis method. It is proposed that a reasonable criteria and analysis method should be adopted, and the current criteria shall be revised to adequate levels considering reasonable basis and industrial technology levels. Also, the test analysis conceptions, separation efficiency method and particle size restriction method, are reviewed to fulfil separation performance test for marine centrifugal purifiers.

Wind Tunnel Test for Scaled Wind Turbine Model (Scale effect correction) (축소형 풍력터빈 풍동시험-축소효과 보상기법)

  • Cho, Tae-Hwan;Kim, Yang-Won;Park, Young-Min;Chang, Byeong-Hee
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.87-93
    • /
    • 2008
  • Wind tunnel test for the 12% scaled model of NREL Phase VI wind turbine was conducted in KARI low speed wind tunnel for $2006{\sim}2007$. The 1st and 2nd test was designed to find out the wind tunnel test method for the blade manufacturing accuracy and surface treatment method by using the composite and aluminum blades. And the 3rd test was designed to study the scale effect. The chord extension method which was used for Bo-105 40% scaled model was adapted for scale effect correction. Test results shows that the chord extension method works well for the torque slope but the maximum torque for scaled model is about 8% below than the real scale model. New correction method to correct this offset was proposed.

  • PDF

A Study on the Pull-out test for Non-Destructive Evaluation of Concrete Strength (콘크리트 비파괴강도 추정을 위한 인발시험법에 대한 연구)

  • 한만엽;김동욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.639-642
    • /
    • 1999
  • Pullout test known as Lok test among the test methods to evaluate concrete strength strength is a test method which is used to decide the form removal time by assessing the early strength of concrete in a new construction, or to control the quality of newly placed concrete. This method has inconvenience to place inserts on the form work in advance, however, the placing work is quite simple and it has advantage that the strength can be measured at field as long as the inserts are placed. In this study, the first step is to investigate the properties of test method itself, by performing the laboratory test which covers deviation of the method and factors affecting the results, etc. The second step is to correlate the result with cylinder strength and other NDT methods such as rebound hammer, ultrasonic method, etc. And that, the results are compared with foreign results to find the differences between the two. In this research, new factors such as moisture content, area of aggregate failure cross section and area of aggregate separation cross section, etc as well as wate-cement ratio and age are investigated.

  • PDF

Application study of C.S.G method by the test construction and field test (시험시공 및 현장시험을 통한 C.S.G 공법의 적용성 검토)

  • Kim, Ki-Young;Park, Han-Gyu;Cho, Sung-Eun;Jeon, Je-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.61-68
    • /
    • 2006
  • Cemented Sand and Gravel(CSG) is a material made by simple mixing of rock-based raw materials such as excavated soil and riverbed gravel together with cement and water. The use of CSG methodl for cofferdam and large dam is gradually increasing in Japan because a quarry and aggregate plants can be diminished. Also, the CSG method can reduce dam construction cost, construction duration and destruction of environment. In this paper, field test and test construction of CSG method was conducted on Hwabuk Dam. The mechanical properties of CSG, such as compressive strength, extention strength and field permeability test were investigated. From the results of the experimental study, application study of CSG method was discussed.

  • PDF

Generation Algorithm of Test Suite for State Transition Sequence with Abnormal Transitions in Robot Software Component (로봇용 소프트웨어 컴포넌트에서 비정상 천이를 포함한 상태 천이 시퀀스용 테스트 스윗 생성 기법)

  • Maeng, Sang-Woo;Park, Hong-Seong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.8
    • /
    • pp.786-793
    • /
    • 2010
  • This paper proposes a new method called the path-history coverage to generate a test suite to test the state transition behavior of the robot SW component. The proposed method generate a test suite which includes abnormal state transitions based on FSM of target component. Especially the proposed method covers the disadvantage of the mutation test method that the size of the test suite is explosively increasing. Examples including OPRoS Component[1] show the validity of the proposed method.

Scan Selection Algorithms for No Holding Partial Scan Test Method (무고정 부분 스캔 테스트 방법을 위한 스캔 선택 알고리즘)

  • 이동호
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.12
    • /
    • pp.49-58
    • /
    • 1998
  • In this paper, we report new algorithms to select scan flip-flops for the no holding partial scan test method. The no holding partial scan test method is identical to the full scan test method except that some flip-flops are left unscanned. This test method does not hold scanned or unscanned flip-flops while shifting in test vectors, or applying them, or shifting out test results. The proposed algorithm allows a large number of flip-flops to be left unscanned while maintaining almost the complete full scan fault coverage.

  • PDF

A Study of Standardization of Floor Slip Test method using O-Y·PSM (경사인장형 바닥 미끄럼 시험방법의 표준화에 관한 연구)

  • Shin, Yun-Ho;Kang, Yong-Hak;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.95-96
    • /
    • 2016
  • The floor slip test method using O-Y·PSM was developed based on the risk assessment and sense of slip by the users implementing actions such as changing walking direction on a floor. This test method is regulated under the Korea Industrial Standard KS M 3510, and in the Korea Industrial Standard KS F 3230, the article of KS M 3510 is cited. Yet, in the standard, the surface condition of test or slip adjustment method is merely mentioned or difficult to be found, and thus it creates confusion in floor slip test using O-Y·PSM. Therefore, this study is to provide the useful data to revise the relative standard through the standardization study including various surface conditions of sample and slip adjustment method used in floor slip test method using O-Y·PSM.

  • PDF

The Estimation of Horizontal Coefficient of Consolidation Using Velocity Method (Velocity Method를 이용한 수평압밀계수 산정에 관한 연구)

  • 김지용;천홍래;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.475-480
    • /
    • 2000
  • This study was to present the method for estimating the horizontal coefficient of consolidation by using velocity method which was based on the Barren's equation. Horizontal drainage consolidation tests, including a radial drainage consolidation test, a cylindrical consolidation test, and a large soil box test, were performed to examine its validity. Using the velocity method, horizontal coefficient of consolidation was calculated and compared with lost method, √t method, Magnan & Deroy's method, Bergado's method.

  • PDF

Low Power Scan Test Methodology Using Hybrid Adaptive Compression Algorithm (하이브리드 적응적 부호화 알고리즘을 이용한 저전력 스캔 테스트 방식)

  • Kim Yun-Hong;Jung Jun-Mo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.4
    • /
    • pp.188-196
    • /
    • 2005
  • This paper presents a new test data compression and low power scan test method that can reduce test time and power consumption. A proposed method can reduce the scan-in power and test data volume using a modified scan cell reordering algorithm and hybrid adaptive encoding method. Hybrid test data compression method uses adaptively the Golomb codes and run-length codes according to length of runs in test data, which can reduce efficiently the test data volume compare to previous method. We apply a scan cell reordering technique to minimize the column hamming distance in scan vectors, which can reduce the scan-in power consumption and test data. Experimental results for ISCAS 89 benchmark circuits show that reduced test data and low power scan testing can be achieved in all cases. The proposed method showed an about a 17%-26% better compression ratio, 8%-22% better average power consumption and 13%-60% better peak power consumption than that of previous method.

  • PDF

Comparison of Alkali-Silica Reactivity for Mortar Bar and Concrete Prism Specimens Using Crushed Aggregates in Korea (국내 쇄석골재를 사용한 모르타르 봉 및 콘크리트 각주 시험편의 알칼리-실리카 반응성 비교)

  • Kim, Seong-Kwon;Yun, Kyong-Ku;Hur, In
    • International Journal of Highway Engineering
    • /
    • v.14 no.5
    • /
    • pp.93-99
    • /
    • 2012
  • PURPOSES: The purpose of this study is to compare the alkali-silica reactivity for mortar bar and concrete prism specimens using crushed aggregates of 5 types in Korea. And the alkali-silica reactivity for those aggregates are measured by chemical test method. METHODS: The alkali-silica reactivity for those aggregates was measured by chemical test method of KS F 2545, mortar-bar test of KS F 2546, accelerated mortar-bar test method of ASTM C 1260 and concrete prism test method of ASTM C 1293, relatively. RESULTS: The alkali-silica reactivity for those aggregates was verified by chemical test of KS F 2546 and accelerated mortar-bar test of ASTM C 1260. However, it was not by mortar-bar test of KS F 2546 and concrete prism test of ASTM C 1293. CONCLUSIONS: The above results showed that relationship among the four test methods were very low. The results from 3 types of test methods using cement-aggregate combinations appeared to be different. Because the environmental conditions of test methods for measuring the alkali-silica reactivity such as equivalent alkali content(external source), humidity, temperature, and times were different though the aggregates were same. Moreover, alkali-silica reactivity showed the biggest impact when alkalis were supplied form outside and exposed to environmental conditions. The accelerated mortar-bar test method seems to be most appropriate test method for concrete structures exposed to alkali environment.