• Title/Summary/Keyword: Test lamp

Search Result 218, Processing Time 0.027 seconds

A STUDY ON LAMP BANK DESIGN OF SOLAR SIMULATOR (솔라시뮬레이터의 램프뱅크 설계에 관한 연구)

  • Baek, S.H.
    • Journal of computational fluids engineering
    • /
    • v.17 no.3
    • /
    • pp.45-52
    • /
    • 2012
  • This paper is a study on the design of the solar lamp bank which is a very important part of the solar simulator with the commercial metal halide lamps and infrared lamps. Lamp Bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. The shape of the ceiling board next to the lamp bank to promote the lamp cooling efficiency and to reduce temperature deviation and air velocity deviation in the chamber is so creative. The ceiling board of partial closed type is the best among several types.

A Thermal Flow Analysis for an Optimal shape of Solar Lamp Bank (최적의 램프뱅크형태를 결정하기 위한 열유동 해석)

  • Baek, Sang-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.82-89
    • /
    • 2012
  • This study is on the thermal flow analysis to select an optimal shape of solar lamp bank. Solar Lamp bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. Among the 4 kinds of lamp bank, since lamp bank type D satisfies uniformity ${\pm}10%$ and also doesn't exceed total irradiance 1,232 $W/m^2$, type D is finally selected.

Comparison to Automobile Pilot Lamp by Accelerated Life Test (가속수명시험을 통한 자동차용 파일럿램프의 비교평가)

  • Shin, Min-Gyung;Wei, Shin-Hwan;Kim, Hyung-Min
    • Journal of Applied Reliability
    • /
    • v.8 no.2
    • /
    • pp.75-85
    • /
    • 2008
  • In this paper, we compared domestic with foreign pilot lamps installed on the instrument board or electronic modules (car audio, air-conditional system, etc.) of an automotive vehicle by an accelerated life test in order to estimate the life of domestic pilot lamps. An accelerated life test method was developed and the relation of the life and voltage stress was analyzed. The main results are as follows; i) $B_{10}$ life of pilot lamp is above 5,000 hours, vehicle travel time for 10 years. ii) the life of domestic pilot lamp is longer than that of foreign thing. iii) the life distribution of domestic pilot lamp is wider than that of foreign thing. iv) it is possible to promote import replacement of automobile pilot lamp.

  • PDF

Comparison of the Effects of Luminous Lamp, and Nonluminous Lamp Radiation on Experimental Pain Threshold Sensitivity (발광·무광 적외선등 조사가 실험적 통증역치에 미치는 효과 비교)

  • Lim, In-Hyuk;Lee, Jeong-Weon;Cho, Su-Won
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study was to compare the experimental pain threshold when used in luminous lamp radiation and nonluminous lamp radiation with healthy person. Thirty normal subjects were randomly assigned two groups: a luminous lamp radiation group, and a nonluminous lamp radiation group. The infrared lamps were applied on L3 for thirty minutes. Each group was measured for experimental pain threshold and local temperature before, 15 and 30 minute radiation. For statistical differences in change of the experimental pain threshold and local temperature due to differences in lamp ray was compared using the independent t-test. And, General linear model for profile plots test was used. The results were as: 1. Local temperature was significantly increased in the nonluminous lamp group (p<.01). 2. Experimental pain thershold was significantly increased in the luminous lamp group (p<.05),(p<.01). This study indicate that luminous lamp radiation was more effects of increase experimental pain thershold than nonluminous lamp radiation. Further study is needed to compare the effects of after period radiation.

  • PDF

Analysis of Impulse Withstand Voltage Performance of Lighting Equipment (조명기기의 임펄스내전압 성능의 분석)

  • Lee, Bok-Hee;Pang, Pyung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

Stability of hair-tail angling fishing boat according to the induction fishing lamp installation (인덕션 집어등을 설치한 갈치채낚기 어선의 복원성능)

  • Seongjae JEONG;Seongwook PARK;Myongkok JEONG;Geumcheol JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • In this study, the stability of fishing boat inducing the change of fishing lamp in accordance with the installation of induction lamp in comparison with metal halide lamp was investigated. Inclining test for 8.55 ton class of hair-tail angling fishing boat was performed in order to find a GM and light weight. A stability calculation of the target fishing boat on the basis of KST-SHIP program was evaluated. The stability of the fishing boat with a metal halide lamp such as induction lamp according to the result obtained by the inclining test is slightly different, and the stability is not so much affected. Due to the induction lamp installation, the wind area increased by about 3.178 m2. Before installing the induction fishing lamp, G0M was found to be 0.209 at full load departure and 0.296 at departure from fishing ground. After installing the induction lamp, the full load departure condition is 0.178 and the fishing ground departure condition is 0.260. The G0M value before and after installation of the induction fishing lamp shows a difference of about 3% at the full load departure condition. The value of the critical angle of inclination definition showed a difference of about 16%. Despite these differences, it is lower than the regulations; it was confirmed that there will be no significant difference unless it is in an overloaded state.

An Accelerated Life Test for Burnout of Tungsten Filament of Incandescent Lamp (텅스텐 백열전구의 필라멘트 단선에 대한 가속수명시험)

  • 이재국;김진우;신재철;김명수
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2004.07a
    • /
    • pp.129-137
    • /
    • 2004
  • This paper presents an accelerated life test for burnout of tungsten filament of incandescent lamp. From failure analyses of field samples, it is shown that their root causes are local heating or hot sports in the filament caused by tungsten evaporation and wire sag. Finite element analysis is performed to evaluate the effect of vibration and impact for burnout, but any points of stress concentration or structural weakness are not found in the sample. To estimate the burnout life of lamp, an accelerated life test is planned by using quality function deployment and fractional factorial design, where voltage, vibration, and temperature are selected as accelerating variables. We assumed that Weibull lifetime distribution and a generalized linear model of life-stress relationship hold through goodness of fit test and test for common shape parameter of the distribution. Using accelerated life testing software, we estimated the common shape parameter of Weibull distribution, life-stress relationship, and accelerating factor.

  • PDF

Stability of fishing vessel according to the LED luring lamp installation (LED집어등 설치에 따른 연안 채낚기 어선의 복원성능)

  • Jeong, Seong-Jae;An, Heui-Chun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.4
    • /
    • pp.623-632
    • /
    • 2014
  • In this study, the stability of fishing vessels get some change in accordance with the installation of LED luring lamp in comparison with metal halide luring lamp were investigated. Inclining test for 9.77 ton class of squid jigging and hair-tail angling vessel was performed in order to make a stability evaluation. A performance analysis of the target vessels to the stability on the basis of KST-SHIP program was evaluated. The results were as follows in this study. The stability of the fishing vessel by a metal halide such as LED and the like according to the result obtained by the inclining test is a slightly present difference, and the stability is not affected. The fishing vessel with LED lamp installed satisfies all the stability criteria specified in law and IMO rule. Compared to the metal halide LED lamp the increase of the height of the center of gravity and the initial transverse metacenter was caused. Due to the LED installation, the somewhat wider wind area of the waterline, which appears as a result, does not lead to an actual increase in rolling period. But then it is necessary to be designed on that the LED lamp shape reduces wind pressure area. Because of LED lamp installation, the GM value of vessels is increasing faster rolling cycle so causes a decrease in the sense that the crew is aboard.

Lifetime Estimation of an Automotive Halogen Lamp (자동차용 Halogen Lamp 의 수명 예측)

  • Kim, Chung-Sik;Shin, Seung-Jung;Kwack, Kae-Da
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1259-1264
    • /
    • 2008
  • This paper presents an accelerated life test for burn out of tungsten filament of automotive halogen lamp. There are many failure modes and failure factors that associated with tungsten filament. But in this explain the dominant failure mode of tungsten filament is the bumout of the filament failure. At first, over voltage, high temperature, inrush current and vibration are selected as stress factors by using of two stage Quality Function Deploymeng(QFD). And we planed accelerated life test that has one factor(voltage) and three levels. By experiment it has absorbed that over voltage has an effect on the life of halogen lamp. Using ALTA programs, we estimated the common shpae parament of Weibull distribution, life-stress relationship and $B_{100p}$ life.

  • PDF

High Temperature Reliability Study of Low Frequency In-door Electrodeless Lamp (무전극형광램프의 고온 신뢰성 연구)

  • Jeong, Ui-Hyo;Hyung, Jae-Phil;Lim, Seong-Yong;Lim, Hong-Woo;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.14 no.3
    • /
    • pp.203-207
    • /
    • 2014
  • Electrodeless lamp is famous for its long life. But its reliability is dependent not only on electrodes but also on materials and structures. To evaluate end product's reliability, we studied high temperature durability by $60^{\circ}C$, $75^{\circ}C$ and $90^{\circ}C$ temperature tests, and predicted failure times by an exponential model through regression analysis. However, the test showed that temperature does not affect degradation of electrodeless lamps. Their luminous outputs degrade during the early time of the test (till 250 hours) and then converge to a saturation points. Also, '410nm ~ 530nm' spectrum degrades more than other spectra.