• Title/Summary/Keyword: Test field

Search Result 9,461, Processing Time 0.038 seconds

A Study on the Field Test of IEC 61850 based Substation Automation System (IEC 61850 변전자동화시스템 실증시험에 관한 연구)

  • Lee, N.H.;Jang, B.T.;Kim, B.H.;Shim, E.B.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.250_251
    • /
    • 2009
  • IEC 61850 based substation automation system mainly consists of human machine interface as a client and a various of IEDs as a server. Both of them should require the field testing for performance verification including IEC 61850 communication services. This means that the test can assure the interoperability of IEC 61850 based substation automation system consisted of multi vendor's products. This paper shows a research result on the field test of the IEC 61850 based HMI and IEDs. And it proposes some engineering solutions for the system implementation.

  • PDF

On the Large Eddy Simulation of Scalar Transport with Prandtl Number up to 10 Using Dynamic Mixed Model

  • Na Yang
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.913-923
    • /
    • 2005
  • The dynamic mixed model (DMM) combined with a box filter of Zang et. al. (1993) has been generalized for passive scalar transport and applied to large eddy simulation of turbulent channel flows with Prandtl number up to 10. Results from a priori test showed that DMM is capable of predicting both subgrid-scale (SGS) scalar flux and dissipation rather accurately for the Prandtl numbers considered. This would suggest that the favorable feature of DMM, originally developed for the velocity field, works equally well for scalar transport problem. The validity of the DMM has also been tested a posteriori. The results of the large eddy simulation showed that DMM is superior to the dynamic Smagorinsky model in the prediction of scalar field and the model performance of DMM depends to a lesser degree on the ratio of test to grid filter widths, unlike in the a priori test.

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

The Characteristics of Strength of Concrete Specimens under Tidal Environment (해양환경에 폭로된 콘크리트 실험체의 역학적 특성)

  • Lee, Joon-Gu;Kim, Meyong-Won;Kim, Kwan-Ho;Joo, Jae-Hong;Kim, Han-Joung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.277-278
    • /
    • 2009
  • The building that supply tidal and splash zone was constructed near Seamangeum Gate Bridge. The specimens that will be tested for maintenance of gate bridge were exposed on the tidal and splash zone, totally about 650(Fig. 1). The characteristics of strength, salt penetration profile, field application of surface repair material and section recover material will be acquired by periodical test. The program was developed to obtain optimal maintenance strategy of gate bridge as a marine concrete structure and to deposit experimental data, lab. test result, field test result, on its D/B. On this paper, we hope to introduce two years exposure data as compressive strength, the modulus of elasticity, the modulus of dynamic elasticity, field adoption of repair and recover materials. As briefly speaking the results, possion's ratio, elasticity, strength was general, but the recover materials have some problems. There was crack between concrete and recover material and delamination figures.

  • PDF

A Study on Verification of PowerRail based on Voltage Drop under Extended Feeding Condition (연장급전 전압강하 계산을 위한 전기철도 급전 시뮬레이터의 검증에 관한 연구)

  • Kim, Joorak
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.331-337
    • /
    • 2015
  • The power flow analysis of electrified railway is required complicated calculation, because of variable load. Train runs trough rail supplied by electric power therefore, the load value in electrified railway system fluctuates along time. The power flow algorithm in electrified railway system is different from general power system, and the power flow simulation is peformed by the particular simulation software. Powerail is simulation software for analysis of traction power supply system developed by KRRI, in 2008. This consists of load forecasting module, including TPS and time scheduling, and power flow module. This software was verified by measured current under normal feeding condition, however, has not been verified by voltage on the condition of extended feeding. This paper presents the verification of PowerRail based on voltage drop under extended feeding condition. This is performed by comparing simulation result with field test. Field test and simulation is done in commercial railway line.

A Study on the Dynamic Behaviors of Ballast Track using Field Test (현장측정을 통한 자갈도상궤도의 동적 거동 분석)

  • Park Yong-Gul;Choi Jung-Youl
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.4 s.35
    • /
    • pp.401-411
    • /
    • 2006
  • The major objective of this study is to investigate the dynamic behaviors of track due to the deterioration characteristics of ballast for servicing tracks by the field test. The durability of ballast plays an important role in the track behaviour. To estimate the deterioration characteristics of ballast, several tests have been carried out by several scholars. The deterioration characteristics of ballast is one of the most important factor in the dynamic behaviour of track and its life. In this paper abrasion/breakage characteristics of ballast is studied to predict the effect of physical ballast characteristics on ballast track. To reveal deterioration characteristics of ballast, the field test were carried out. The deterioration characteristics, studied in this paper, is applied to the dynamic behaviour of track in various conditions.

Wobble and Nonconcentricity Effects in Eddy Current Test of Tubes or Rods (튜브, 봉류의 와전류 탐상시 시편 변위에 의한 신호 변화)

  • Kim, Y.J.;Kim, Y.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.2
    • /
    • pp.37-41
    • /
    • 1989
  • The purpose of this paper is to estimate the effect of wobble and nonconcentricity of tubes or rods in eddy current test with encircling test coils. Because the eddy current induced in a sample is related to the total magnetic flux linkages, the information about magnetic field distribution in a coil is important. In theoretical study, magnetic field distribution in a single turn coil was calculated and variation of impedance according to the difference of sample positions was presumed. Magnetic field intensity at inside of a solenoidal coil was measured and compared with the theoretical estimation. In experiment, impedance loci of a coil encircling an aluminum rod were measured at different sample positions. The effect of crack positions was examined at same sample positons.

  • PDF

1Gbps x 16 channel Wavelength Division Multiplexing-Passive Optical Network Field Trial Test (1Gbps x 16채널 WDM-PON 필드 테스트)

  • Kim, Geun-Young;Park, Hyung-Jin;Kim, Jin-Hee;Jeong, Ki-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.9A
    • /
    • pp.704-711
    • /
    • 2009
  • In this paper, we report the results of the field trial test of 1GbpsX16channels Injection locking FP-LD based WDM-PON system which could guarantee 40Mbps minimum bandwidth per subscriber, We have confirmed the system reliability, also verified that the system could reliably deliver the service such as internet, VoD through the systems during the field trial test.

The first report of a study for Field Diagnosis of Large High Voltage Motors (대용량 고압전동기 현장진단연구(I))

  • Park, D.K.;Song, Y.C.;Kim, J.H.;Ryoo, H.S.;Sun, J.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1731-1733
    • /
    • 1998
  • This report is the first intermediate report of a series of field test result of large high voltage motors. Major specimens were 3.3/6.6kV class pump motor that was installed and operated for public water service by KOWACO(KOrea WAter resources COperation). The capacity of specimen motors were in range of several hundred kVA. Until now, we get the 22 field test result by testing technique discribed in IEEE standards and discharge-map technique reported by Japanese engineers. The test result were varied very wide range, and there was a tendency according to insulation material and manufacture.

  • PDF

Studies on Properties of Avian Reovirus Isolated in Korea (국내에서 분리한 닭 레오바이러스의 성상에 관한 연구)

  • 김성식;박병옥;김순재
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.1
    • /
    • pp.67-80
    • /
    • 1992
  • Avian reoviruses have been implicated in respiratory disease enteric conditions including Cloacal pasting in young thicks, pericarditis, hydropericardium, anaemia with swollen spleen and liver and petechiation of skeletal muscle and viral arthritis. This study was conducted to examine properties of reovirus field 3 strains isolated from affected broiler from several farms. An infectious agent was isolated from leg tendons and intestine of broiler with clinical tenosynovitis. The agent grew well on the chicken embryo kideny cells(CEK). One of them produced cytopathic effects(CPE) of round type and formed intranuclear inclusions, and the other was characterized by CPE of syncytical type and cytoplasmic inclusion. The properties and serological classification of field strains were examined by hemagglutin test, virus neutralization test, agar gel precipitin, electropherotype. They showed no hemagglutination reactions and not well neutralization and to possess common antigens detectable by AGP test. RNA electropherotype presented 10 segment band as the previous report. These data suggest that the field strains and standard strains (1133, 1733) may be the same group.

  • PDF