• Title/Summary/Keyword: Test field

Search Result 9,461, Processing Time 0.036 seconds

A Case Study of Hot In-Place Recycling Asphalt Mixture in Korea (국내 현장가열재생아스팔트 시공 혼합물 시험평가)

  • Kwon, Sooahn;Yang, Sunglin;Lee, Jaejun;Hong, Jaecheong;Lim, Jaekyu
    • International Journal of Highway Engineering
    • /
    • v.15 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • PURPOSES: This study is to investigate the Hot In-Place recycling asphalt mixture in Korea using field produced materials. METHODS: Hot In-Place reclaimed asphalt mixture was investigated to evaluate the mixture properties based on various test results such as Marshall Test, Indirect Tensile Test, TSR, and Wheel Tracking Test. These test values were compared with domestic standard specification. RESULTS: The result of the laboratory experiment indicates that the Hot In-Place Reclaimed(HIR) asphalt mixture produced at the field constrution site was satisfied all of the test criteria such as Indirect tensile test, Marshall and TSR test, and wheel tracking test. During the test, the research team found that current HIR system is required an extention of mixing time to improve quality and to reduce variation of sample to sample. Although the current HIR mixture was passed the test criteria, there is a potential capability to enhance the mixture properties as extend mixting time. CONCLUSIONS: Based on these laboratory test results, It would be concluded that domestic HIR mixture's properties were satisfied all standard specification related with evaluation of recycling asphalt mixtures. Based on this case study result, there is a chance to save construction cost and increase the usage of reclaimed asphalt concrete in the future.

Research for Installation and Operation of High Temperature Superconducting Cable System (고온 초전도 케이블 시스템 설치 밀 운전을 위한 연구)

  • Choi, Hyung-Sik;Sohn, Song-Ho;Hwang, Si-Dole
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.653-657
    • /
    • 2005
  • The commercial contract was made firstly in the world for one set of high temperature superconducting(HTS) cable system between buyer, Korea Electric Power Research Institute and seller, Sumitomo Electric Industries, Ltd. in August 2004. After fabrication, test and examination, the HTS cable system will be installed at the KEPRI's test field in Gochang, Jeonbuk province from the time of July 2005. KEPRI is preparing measurement and test facilities for field test of the HTS cable system and carrying out researches into the design and construction of superconducting cable test building, evaluation of cooling performance, measurement of AC loss, analysis of the quench phenomena due to excess current and means of linking the HTS cable system to the existing electric power supplying system. The constitution of, the method to install and the plan of test operation of the HTS cable system will be presented in this paper.

  • PDF

Application of in-situ testing Methods for Bearing Capacity Estimation of Railroad Roadbed (철도 노반의 지지력 평가를 위한 현장 시험법 적용성 연구)

  • Park, Chang-Woo;Choi, Chan-Yong;Lee, Il-Wha;Kim, Dae-Sang
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.866-875
    • /
    • 2006
  • The field plate load test a good potential for determining modulus since it measures both plate pressure and settlement. However, because The field plate load test is expensive and takes plenty of time for operation, it is very difficult to figure out the test characteristics of railroad roadbed in detail. For faster and economical operation, the Dynamic Cone Penetrometer(DCP) and the Light Falling Weight Deflectometer(LFWD) have been utilized for estimating the bearing capacity of railroad roadbed. The objective of this study is to determine the relationship between the test(PLT, DCP, LFWD) of the railroad roadbed in Korea. The DCP test and LFWD test for evauluating the strength of railroad roadbed materials produced in Korea are presented in this paper.

  • PDF

Comparative Study of Dutch Cone and Piezocone Penetration Test on Soft Ground (연약지반에 대한 더치콘과 피에조콘 관입시험 비교 연구)

  • 원정윤;장병욱;우철웅;윤상묵
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.96-106
    • /
    • 2003
  • 134 Dutch cone (mechanical cone) and 9 piezocone (electronic cone) penetration tests have been performed in the southwestern part of Korea. In general, Dutch cone results may be different from that of piezocone due to the difference in structure of the cones. 6 Dutch cone and piezocone test data which were obtained at the same point respectively, were analyzed and plotted in soil classification chart proposed by Robertson et. al.(1986, 1990). Cone factors of Dutch cone and piezocone test empirically have been determined using laboratory and field vane test results. Using this cone factors, it was shown that there was good correlation between shear strength estimated using cone resistance and that of laboratory test and field vane tests. It was found that there was a good correlation between cone resistance from Dutch cone and that from piezocone. Relationship formula was also suggested. Dutch cone test provides a useful means for stratigraphic profiling in large project and has some advantage over piezocone in particular situations, such as very soft clay ground and dredged area.

A Method of Failure Detection Rate Calculation for Setting up of Guided Missile Periodic Test and Application Case (유도탄 점검주기 설정을 위한 고장 탐지율 산출 방안 및 적용 사례)

  • Choi, In-Duck
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.2
    • /
    • pp.28-35
    • /
    • 2019
  • Since guided missiles with the characteristics of the one-shot system remain stored throughout their entire life cycle, it is important to maintain their storage reliability until the launch. As part of maintaining storage reliability, period of preventive test is set up to perform preventive periodic test, in this case failure detection rate has a great effect on setting up period of preventive test to maintain storage reliability. The proposed method utilizes failure rate predicted by the software on the basis of MIL-HDBK-217F and failure mode analyzed through FMEA (Failure Mode and Effect Analysis) using data generated from the actual field. The failure detection rate of using the proposed method is applied to set periodic test of the actual guided missile. The proposed method in this paper has advantages in accuracy and objectivity because it utilizes a large amount of data generated in the actual field.

Experimental Study on Condition Evaluation for Railway Ballasted Track (자갈궤도의 상태평가를 위한 실험적 연구)

  • Choi, Jung-Youl;Bahng, Eun Young
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.152-157
    • /
    • 2018
  • The degradation and damage of the components for ballasted track could be caused a serious problem for railway safety. Therefore, the integrity evaluation of ballasted track condition is important to ensure and predict that the track safety and track maintenance. Various track components such as rail pad, ballast, sleeper, and rail that are widely used in Republic of Korea and represent a range of physical properties have been selected for this research. In this study, the experimental modal analysis was performed by the non-destructive testing. Modal test results were obtained from the field test and used to assess the condition of the track components. From the field test, the system of ballasted track was found to be simplified as a two-degree-of-freedom(2DOF) dynamic system. The condition of track component was found to directly affect the dynamic response of ballasted tracks. As the results, the dynamic properties of the track component was depend on the track condition and was distributed more roughly and over a wider range than its initial design values. Further, the methodology presented in this study is possible to determine experimentally the fundamental track parameters which are required in the numerical analysis, and also are useful for the safety assessment of track condition.

롯드 체결에 따른 에너지 전달 평가

  • Bae, Myeong-Ho;Yoon, Hyung-Koo;Kim, Ju-Han;Lee, Jong-Sub
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.171-175
    • /
    • 2010
  • Various soil characteristics for safe construction is necessary to understand the tests using the samples collected, and head in place an energy evaluation is conducted to evaluate the ground. In-Situ testing ground, Rod length and around the intrusive when the energy loss due to friction has been measured only in the head. Abstract The purpose of this agreement when increasing contract area of Rod agreement to transform the energy attenuation and the attenuation at the energy being delivered to evaluate. To this end, the same material used in the field test, laboratory test to apply Rod diameter and length have been considered, designed to perform the experiment was to use the Rod. Energy that raised at head of Rod, was increased and decreased by contracting type. The energy difference occurs in the head with the tip that shows the energy rating may be required at the tip is showing. Abstract The energy evaluation for the Rod field test to be at the basic sources and will be able to calculate the trusted information are measured from the tip.

  • PDF

A study on Automatic field Test Equipment with improved maintenance and environmental reliability

  • Lee, Seok-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.3
    • /
    • pp.9-16
    • /
    • 2018
  • In this paper, I purpose one of the development methods for portable Automatic field Test Equipment(ATE) with VME form factor. Almost portable ATE have not used to standards form factor and they are connected by mechanical non-rigid general connectors and wire harnesses among the components. Furthermore, it is hard to reuse developed board. So, it decreases to reusability of developed board and it is hard to maintenance of ATE. Even those things have weakness for vibration and drop test especially in portable ATE. The XK9A1 ATE using VME form factor has environmental reliability through vibration, drop, temperature test. It consists of 5 developed board called the control board, the wire & wireless communication board, the power supply board, the load board and the mother board. It is connected by two wire harnesses between mother board and extern circular connectors. The control board send the data and address to other board though each 16-bit data and 20-bit address line. You can develop the function board what you want to using those data & address line when it comes to needing other function board.

Field Application of New Seismic Site Characterization Using HWAW(Harmonic Wavelet Analysis of Wave) Method (HWAW(Harmonic Wavelet Analysis of Wave) 방법을 이용한 새로운 탄성파 지반조사기법의 현장 적용)

  • 박형춘;김동수;이병식
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.6
    • /
    • pp.51-59
    • /
    • 2004
  • The evaluation of shear modulus is very important in various fields of civil engineering. In this paper, the site characterization method using HWAW method is applied to determine shear wave velocity profile of two test sites in order to verify the field applicability of HWAW method. Shear wave velocity profiles by HWAW method are compared with shear wave velocity profiles by SASW test and PS-Suspension Logging test. Through field applications, it is shown that HWAW method can minimize the effect of noise and lateral non-homogeneity of the site and determine detailed local shear wave velocity profile of site.

The Study on Field Test of the New Formulated and Commercial Diesel Engine Oils (제조 디젤엔진 오일과 상업용 디젤엔진 오일의 실차시험 연구)

  • 김영운;정근우;강석춘
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.51-59
    • /
    • 2001
  • A diesel engine oil formulated in KRICT and a commercial diesel engine oil (API CG-4) were tested by car and their Kinematic Viscosity, TAN, TBN, metal content, additive depletion, anti-wear property and IR analysis were analyzed. From the research, both of the tested oils had almost the same properties f3r the change of TAN and TBN, but the change of Kinematic Viscosity of formulated oil was slightly higher than that of commercial oil. The iron content in the commercial oil increased rapidly from 7000 km while that of the formulated oil was still low. These results were confirmed by the anti-wear test with a 4-ball wear test machine for the each samples. Also, for the commercial oil, the depletion factor of the Zn-DTP which was added as an anti-wear property did not change any more after 7000 km. But, that of the formulated oil changed continuously to 8000 km, which means that the ability to prevent wear of the sliding pairs exists for the formulated oil. From the analysis results of oil properties obtained by field test, it was found that the commercial oil could be used only within 7000 km, but the formulated oil could be used more than 8000 km without severe wear of the sliding parts in the diesel engine.

  • PDF