• 제목/요약/키워드: Test Temperature

검색결과 10,040건 처리시간 0.036초

링 시험편을 이용한 ZIRLO 피복관의 크리프 특성 평가 (The Evaluation of the Creep Properties of ZIRLO Cladding Using the Ring Specimen)

  • 배봉국;구재민;석창성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.279-284
    • /
    • 2004
  • In this study, we suggested the ring creep test using the ring specimen of Arsene for estimating the burst creep properties of the cladding in stead of burst creep test. For this objective, we used the load-displacement conversion relationship of ring specimen called LCRR which had been determined on our previous study at high temperature by performing the ring tensile test and the numerical analysis. Then we carried out both the ring creep test and the burst creep test between 350 $^{\circ}C$ and 600$^{\circ}C$ which were higher then the in-service temperature of the cladding in a reactor. The creep properties from the ring creep test with applying LCRR were compared with those from the burst creep test of closed-end specimens. From the results, it could be seen an very strong relationship between them, especially in Larson- Miller parameter. So, it is expected that we can easily anticipate the creep properties of not only claddings but also various small pressure pipes using the ring creep test.

  • PDF

링 시험편을 이용한 ZIRLO 피복관의 크리프 특성 평가 (The Evaluation of the Creep Properties of ZIRLO Cladding Using the Ring Specimen)

  • 배봉국;구재민;석창성
    • 대한기계학회논문집A
    • /
    • 제29권7호
    • /
    • pp.964-969
    • /
    • 2005
  • In this study, we suggested the ring creep test using the ring specimen of Arsene for estimating the burst creep properties of the cladding in stead of burst creep test. For this objective, we used the load-displacement conversion relationship of ring specimen called LCRR which had been determined on our previous study at high temperature by performing the ring tensile test and the numerical analysis. Then we carried out both the ring creep test and the burst creep test between $350^{\circ}C$ and $600^{\circ}C$ which were higher than the in-service temperature of the cladding in a reactor. The creep properties from the ring creep test with applying LCRR were compared with those from the burst creep test of closed-end specimens. From the results, it could be seen an very strong relationship between them, especially in Larson-Miller parameter. So, it is expected that we can easily predict the creep properties of not only claddings but also various small pressure pipes using the ring creep test.

ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.928-940
    • /
    • 2017
  • An experiment using the $Prim{\ddot{a}}rkreisl{\ddot{a}}ufe$ Versuchsanlage (PKL) was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF) on a cold leg smallbreak loss-of-coolant accident with an accident management (AM) measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG) secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

우리나라 온천의 온도 및 성분 특징 (Temperature and Compositional Characteristics of the Hot Spring Water in Korea)

  • 이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.121.1-121.1
    • /
    • 2010
  • We analyzed the temperature and chemical composition of 376 hot springs in Korea. It took about three days for the temperature to stabilize after the pumping test. After the stabilization, in-situ and laboratory analyses of the hot spring water were carried out. The average temperature and TDS were $29.95^{\circ}C$ and 2,071mg/L, respectively. The temperature ranging $25-30^{\circ}C$ were recorded from 70% of hot springs, and $30-35^{\circ}C$ of 15.4%. The maximum temperature was about $78^{\circ}C$. The value of TDS in 79% of the wells was below 1,000 mg/L. 5.5% of the wells, mostly developed near seashore, shows higher values than 10,000mg/L of TDS suggesting the influence of seawater. The hot spring water shows 8.49 of pH representing a weak alkali. For the mineral compositions dissolved in the hot spring in Korea, Na (431 mg/L) and Ca (188 mg/L) are the major cations, and Cl (840 mg/L) and $SO_4$ (213 mg/L) are the major anions.

  • PDF

인삼 복용 전후 체표온도의 변화에 관한 임상적 연구 (A Clinical Study on the Effect of Ginseng to Control Superficial Body Temperature)

  • 최가야;조정훈;장준복;이경섭
    • 대한한방체열의학회지
    • /
    • 제2권1호
    • /
    • pp.49-55
    • /
    • 2003
  • In Oriental medicine, Ginseng had been used for many diseases widely. It's main effects are suppling Qi and Promoting metastasis. The objective of this study is to examine the effect of Ginseng on control of body temperature. We conducted this study with 24 volunteers who had no problem in their health from November 2002 to January 2003. The body temperature were measured by DITI and thermometer before taking Ginseng and after 30minutes of the taking Ginseng extract 15g. We observed the difference of temperature among face chest and upper abdomen. All data were coded for computer analysis and significance were tested by Paired t-test and independent-t-test. According to our study, the axillary temperature show no signifiant change between two groups. The difference of temperature$({\Delta}T)$ between face and upper abdomen significantly increase after taking Ginseng extract(p<0.01). The difference of temperature$({\Delta}T)$ between face and chest significantly increase after taking Ginseng extract(p<0.05).

  • PDF

22Cr-15Ni-5W 슈퍼 오스테나이트계(系) 스테인리스강(鋼)의 고온산화(高溫酸化) 및 내식성(耐蝕性)에 미치는 결정립(結晶粒) 크기의 영향(影響) (Effect of Grain Size on Corrosion Resistance and High Temperature Oxidation Behavior of 22Cr-15Ni-5W Super Austenitic Stainless Steels)

  • 김효종;이해우;이종문;강창룡
    • 동력기계공학회지
    • /
    • 제10권3호
    • /
    • pp.51-57
    • /
    • 2006
  • The effect of grain size on corrosion resistance and high temperature oxidation behavior was studied in 22Cr-15Ni-5W super austenitic stainless steels for desulfurization equipment as a heat power station. In the high temperature oxidation test, oxidation rate was increased as the temperature increased from $600^{\circ}C\;to\;800^{\circ}C$. In vapor, oxidation rate was faster than that in air. Because the vapor was inhibited nucleation of $Cr_2O_3$ film. And the high temperature oxidation resistance at $600^{\circ}C{\sim}800^{\circ}C$ was excellent from all specimens and specimen of the smallest grain size was the most excellent. Because increasing of diffusion course through the grain-boundary was promoted nucleation and growth of $Cr_2O_3$ film. In the test temperature at $600^{\circ}C{\sim}800^{\circ}C$, Cr rich round particle oxide was formed in air, whereas Fe rich needle type oxide was developed in vapor.

  • PDF

일체형 주상용 몰드 변압기의 온도분포 및 특성 비교 (Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding)

  • 조한구;이운용;강택수;최인혁
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

불확실한 온도 조건하의 모형 강 판형교의 진동기반 손상 모니터링 (Vibration-Based Damage Monitoring in Model Plate-Girder Bridges under Uncertain Temperature Conditions)

  • 박재형;홍동수;조현만;김정태
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.75-82
    • /
    • 2008
  • A vibration-based damage-monitoring scheme is proposed that would generate an alarm showing the occurrence and location of damage under temperature-induced uncertainty conditions. Experiments on a model plate-girder bridge are described, for which a set of modal parameters was measured under uncertain temperature conditions. A damage-alarming model is formulated to statistically identify the occurrence of damage by recognizing the patterns of damage-driven changes in the natural frequencies of the test structure and by distinguishing temperature-induced off-limits. A damage index method based on the concept of modal strain energy is implemented in the test structure to predict the location of damage. In order to adjust for the temperature-induced changes in the natural frequencies that are used for damage detection, a set of empirical frequency correction formulas is analyzed from the relationship between the temperature and frequency ratio.

연속 살균기의 온도제어 및 최적설계에 관한 연구 (Study on Temperature Control and Optimal Design for Continuous Sterilizer)

  • 박철재
    • 대한기계학회논문집A
    • /
    • 제39권8호
    • /
    • pp.813-821
    • /
    • 2015
  • 본 논문에서는 배치식 살균기의 문제점을 분석하여 연속 살균기를 모델링하고 설계하였으며 온도편차를 제어하였다. 살균기의 노즐 직경, 홀 직경, 노즐 길이 등의 설계 파라미터를 이용하여 온도를 해석하였다. 살균기의 온도편차에 중요한 노즐 직경, 제트박스의 직경, 노즐의 홀 피치 등의 설계 파라미터를 반응표면분석법에 의하여 최적화하였다. 그리고 본 연구에서 제안한 설계 파라미터를 이용하여 살균기의 실험장치를 개발하여 온라인으로 테스트를 실시하였다. 온라인 테스트 결과 목표온도까지 상승하는데 약 7.3 min 소요되었고 온도편차는 약 $0.84^{\circ}C$로 양호하였으며 해석적으로 최적화를 실시한 결과와 동일한 최적조건을 도출하였다.

외부온도가 수송용 메탄올연료전지 성능에 미치는 영향 (Effects of environmental temperature on the performance of direct methanol fuel cell for vehicles)

  • 한창화;최지선;정대승;한상훈;이중희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.176-179
    • /
    • 2009
  • The performance of direct methanol fuel cells is affected by operating conditions such as, methanol feeding temperatures, methanol concentrations, and methanol flow rates during the operation in different environmental conditions. In this study, effects of the environmental temperature on performance of direct methanol fuel cells have been investigated in order to test a applicability of direct methanol fuel cell to the vehicle. The environmental temperature (ET) was varied from $-20^{\circ}C$ to $+30^{\circ}C$. The inside fuel cell temperature (CT) during test at various operating conditions was monitored and the performance of fuel cell was measured in the I-V polarization curve. With increasing the ET, the performance of the fuel cell was significantly improved and the CT also almost linearly increased. However, at below $0^{\circ}C$ ET, the DMFC showed very poor performance and needed to control CT or methanol feeding temperature (MFT), methanol flow rate(MFR) to obtain enough power of the vehicle.

  • PDF