• Title/Summary/Keyword: Test Set Construction

Search Result 309, Processing Time 0.029 seconds

The Status of the High Enthalpy Plasma Test Facility in Chonbuk National University (전북대 고온플라즈마 설비 구축현황)

  • Choi, Seong-Man;Shin, Eui-Sup;Suh, Young-Sug;Seo, Jun-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.417-420
    • /
    • 2010
  • The high enthalpy plasma research center in Chonbuk national university is under construction with the support of the ministry of the education, science and technology as a fundamental research project The project periods are five year and started at July, 1, 2009. The total project budget is about 39,300 million Won. Four types of plasma equipment will be installed in this research center during the project periods. The equipments are 1 set of 0.4 MW class enhanced Huels type plasma equipment, 1 set of 2.4MW class enhanced Huels type plasma equipment, 1 set of 60Kw RF plasma equipment and 1s set of 200 kW RF plasma equipment.

  • PDF

Development of an Electronic Simulator for Efficiency Improvement to Verify Electro-Hydraulic Servo Controllers in an Examination Set-up (점검환경에서 유압서보제어기 검증효율을 개선하기 위한 유압식 구동장치 시뮬레이터 개발)

  • Han, Seung Chul
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.50-57
    • /
    • 2017
  • Recently, methods of verification for electro-hydraulic servo controllers are various and the required number of testing controllers is continuously increasing in some specific systems. In this study, a PCB-based electronic simulator of hydraulic actuators is designed and developed to simplify test set-up for controllers and to facilitate alteration for characteristics of the simulator. Several features to reduce required time and manpower for verifying controllers are described. Especially, the simulator is considerably efficient to examine some controllers for different hydraulic actuators in a test. Response characteristics of the simulator are compared with those of real actuators to demonstrate validity of this method. Results reveal utilizing the designed simulator for inspecting controllers is equally effective as using hydraulic actuators.

A Basic Study on the Mobile Separator and Sorter Development of Small and Medium-sized Discharge Site's Mixed Construction Waste in Rural Area (농촌지역 혼합건설폐기물의 중·소규모 배출현장용 이동식 분리선별기 개발을 위한 기초연구)

  • Kim, Byung-Yun;Park, Ji-Sun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.21 no.3
    • /
    • pp.17-24
    • /
    • 2019
  • This study aimed to develop a mobile separating and sorting device for discharge sites to separate and sort mixed construction waste generated in small and medium scale in small provincial cities into inorganic materials and combustible materials. The study results can be summarized as follows: 1) As a result of analyzing the existing domestic technology for the separating and sorting mixed construction waste, a device sorting the waste by fusing the vibration screen, disc screen, air blowing methods and the separating and sorting the combustible waste is applied in Korea. 2) In foreign countries, the air blowing, screen, gravity sorters are used for separating and sorting combustible waste in the same way as in Korea. Especially German T Company suggests a construction waste separating and sorting system using an optical sorter. 3) As for the test device for separating and sorting mixed construction waste to be buried in landfill, the processing capacity was set as 16 tons per day. 4) For separating and sorting inorganic materials by granularity, this study set a trommel with two types of diameter as a basic. To operate the mobile all-in-one system, the device is designed to locate a conveyor, a combustible waste conveying device, inside of the trommel. 5) The device is designed in a mobile mode under the concept of primary separating and sorting device, and it can be transported using a 2.5-ton truck minimum. The diameter and length of the trommel are designed to be within 1500mm and 3000mm, respectively. In a further study, an optimized separating and sorting technology is planned to be presented through an experimental study for processing efficiency analysis at the mixed construction waste site by manufacturing the pilot experiment facility reflecting the design elements in the result of this study.

A Case Study on the Design and Drivability Criteria of Steel Pile in Offshore (해상 강관말뚝의 설계 및 항타시공관리 사례연구)

  • Song, Myung-Jun;Park, Yung-Ho;Yoo, Seok-Jun;Sim, Dong-Hyun
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.75-85
    • /
    • 2006
  • The project comprised the construction of the new oil pier and associated topside facilities and demolition of exiting south pier. The site is located approximately 33km south of Kuwait city at MAA refinery. The approach trestle and berth structures of the new oil pier were designed to be supported by steel tubular piles Total 2,480 numbers of piles(795 piles at Approach Trestle, 1187 piles at Berth 1 -4 and 498 piles at Berth 5-6) had to be driven through the calcareous silty sand In this study, the design procedures for offshore steel pipe piles, evaluation for the compression and tension capacities by static and dynamic load test and effective driving criteria by the final set values are discussed

  • PDF

A STUDY ON THE INTRODUCTION OF THE PAY ADJUSTMENT SYSTEM FOR THE VOLUNTARY ASSURANCE OF QUALITY BY THE CONTRACTORS

  • Byung-Ok Noh;Sang-Beom Lee;Jai-Dong Koo
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.521-525
    • /
    • 2011
  • Although the Korean construction industry has risen rapidly, the quality of the buildings is not met with the industry standard compared to the potential of the technology development and the cost of maintenance has been increased. The user's request for quality have been increased, but in the current building construction, the contractors only follow the specifications of design, material and technology, and their main concern is whether they are in right track with the specification or not. Thus, the necessity of developing technology has been ignored and sufficient opportunities for the development have not been provided as well. In the developed countries, in contrast, the quality assurance and the payment regulation system has been utilized for the active response to the changes of users' request. As a result of this, the maintenance cost has been decreased and the development of construction technology has been improved. Therefore the pay adjustment system is needed to create the improvement of the quality of the buildings by the contractors' earnest building construction. In order to introduce the pay adjustment system suitable to the Korean construction industry, this study presented the logical method of adjusting the construction cost and making payment with the pay adjustment index that is created based on the result of the performance test, after making a set of the indicators of the building performance standard and applied them to the targeted building.

  • PDF

Component and Bench Tests of Polyurethane Hydraulic Reciprocating Seal for Accelerated Life Testing (부품 및 벤치 실험을 통한 폴리우레탄 유압 왕복 실의 가속 실험)

  • Je, Youngwan;Kim, Hansol;Kim, Lyu-Woon;Chung, Koo-Hyun;An, Joong-Hyok;Jeon, Hong-Gyu
    • Tribology and Lubricants
    • /
    • v.30 no.5
    • /
    • pp.271-277
    • /
    • 2014
  • Hydraulic reciprocating seals have been widely used to prevent fluid leakage and to provide lubricant film on counter surface in various hydraulic system. The degradation of the seal may cause the catastrophic failure of the hydraulic system. To assess the durability of the seals and the compatibility with counter surface, accelerated life testing (ALT) has been typically employed from industry. However, ALT often takes up to a few months to cause a failure of the seals, and therefore, there is a need to develop more efficient ALT methods. In this work, the degradation characteristics of polyurethane (PU) seals from field test are investigated and they are compared to those from the component and bench tests, with an aim to contribute to the development of ALT method. From the comparison of the cross-sectional profiles of the sealing surface of the PU specimens before and after the tests, both wear and compression set are found to be responsible for degradation of the PU seals. It is also shown that the major wear mechanisms of the PU seals from the field is abrasive wear and formation of pits. The component and bench tests performed in this work are shown to reproduce such wear mechanisms, and therefore, those test methods can be used as an ALT method for PU seals. In particular, the bench test proposed in this work may be effectively utilized to assess the durability and the compatibility of the seals with the counter surface. The results of this work are expected to aid in the design of ALT for PU seal.

A Study on the loading test for of slab by Fire damaged (화재피해를 입은 RC 슬래브의 재하실험에 관한 연구)

  • Lee, Kyu Min;Kang, Seung Goo;Kim, Dong Jun;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.50-51
    • /
    • 2013
  • In case of Korea, it goes frequently that underground parks has been burned. Based on standard temperature time curve(ISO-834), gerber, walls, slab of structures are constructed. However, Standard temperature time Curve is not considered that buildings are affected by vehicle fire. that is why it has the hazard that makes building reinforcement feeble. Based on the result that got from vehicle experiment before, we made four RC slab in this experiment and set the fire severity. according to the loading experiment after heating, we measured the effects that makes reinforcement and shape changes. Furthermore, we examined the safty of the structure by comparing before and after heating.

  • PDF

A Study on the Application State of the Fenestration Energy Consumption Efficiency Rating System in Construction Field (소규모 민간건축 시공현장에 있어서 창호에너지 소비효율등급제의 적용 현황에 관한 연구)

  • Kang, Suk-Pyo;Jin, Eun-Mi;Yun, Yeo-Myun;Park, Sang-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.24-25
    • /
    • 2014
  • Up to now, most the fenestration industry is consisted of glazing and window frame in Korea. According to the Fenestration Energy Consumption Efficiency Rating System and Energy Saving Design Standards of Buildings, u-value of fenestration is defined as the value of calculation with glazing and frame. For this reason, when applying for a building permit, in most cases, the official approval test report of the set of windows and doors is used. Nevertheless, in windows construction progresses, most construction manager take delivery of the glazing and frame separately. For those reason, windows and doors are constructed regardless of the report of the Fenestration Energy Consumption Efficiency Rating System in most construction fields. From now on, the research of the connection method between reality of policy and reality of construction fields should be carried out.

  • PDF

Engineering Characteristics Assessment of Rapid Set Controlled Low Strength Material for Sewer Pipe Using Excavated Soil (굴착토를 활용한 속경성 유동성 채움재의 공학적 특성 평가)

  • Kim, Young-Wook;Lee, Bong-Chun;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.450-457
    • /
    • 2020
  • In this study, engineering characteristics such as flowability, segregation and compressive strength by age to derive fast hardening material mixing proportion using excavated soil. And based on optimal mixing proportion, field simulation experiment conducted in laboratory to examine the effectiveness of the method such as kelly ball drop test and soil penetration test for reviewing the following process. As as a result of evaluation, in case of kelly ball drop test and soil penetration test were securing the following process initiation time 3 hours after place CLSM. As results of these assessments, kelly ball drop test and soil penetration test were applicable for revewing following process in construction field besides unconfined compressive strength method.

Rheological Properties of Super Early Hardening Cement Paste Using Set Controlling Agent (응결조절제를 첨가한 초속경 시멘트 페이스트의 유동 특성)

  • Yang Seung-Kyu;Um Tai-Sun;Lee Jong-Ryul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.413-416
    • /
    • 2005
  • The super early hardening cement is widely used for reducing construction period. But there are some problems with handling the cement because the loss of workability is so big to control. In this study, the fluidity properties of super early hardening cement paste was evaluated at early age of hydration by using gel-time determination method. 4 types of set controlling agent were selected and combinations of them were used for gel-time test. As a result, the gel-time of super early hardening cement paste was extended up to 20 minutes by using the combinations of several types set controlling agent.

  • PDF