Journal of the Korean Society for Precision Engineering
/
v.18
no.2
/
pp.111-118
/
2001
Tungsten probe is the most important part of a probe card, which is widely used for the performance test of wafer chips. Electro chemical etching becomes an exclusive choice for mass production of the tungsten probes. In the mass production, not only the shape of the probe but also the shape distribution of machined probes is important. A new method is proposed for the mass production of the tungsten probes. Tungsten wires are separated by a distance, and dipped into electrolyte. The dipping rate is controlled to shape the probes. Several experimental tests are performed to study the machining characteristics. From the test results, machining parameters including electrical conditions and anode position showed significant influences on the shape, repeatability, precision and quality of sharp tips.
The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.
We have developed a cost effective test socket for ball grid array(BGA) integrated circuit(IC) packages using BeCu metal sheet as a test probe. The BeCu furnishes the best combination of electrical conductivity and corrosion resistance. The probe of the test socket was designed with a BeCu cantilever. The cantilever was designed with a length of 450 ${\mu}m$, a width of 200 ${\mu}m$, a thickness of 10 ${\mu}m$, and a pitch of 650 ${\mu}m$ for $11{\times}11$ BGA. The fabrication of the test socket used techniques such as through-silicon-via filling, bonding silicon wafer and BeCu metal sheet with dry film resist(DFR). The test socket is applicable for BGA IC chip.
Polygraph examination, statement validity analysis and P300-based concealed information test are major three examination tools, which are use to determine a person's truthfulness and credibility in criminal procedure. Although polygraph examination is most common in criminal procedure, but it has little admissibility of evidence due to the weakness of scientific basis. In 1990s to support the weakness of scientific basis about polygraph, Farwell and Donchin proposed the P300-based concealed information test technique. The P300-based concealed information test has two strong points. First, the P300-based concealed information test is easy to conduct with polygraph. Second, the P300-based concealed information test has plentiful scientific basis. Nevertheless, the utilization of P300-based concealed information test is infrequent, because of the quantity of probe stimulus. The probe stimulus contains closed information that is relevant to the crime or other investigated situation. In tradition P300-based concealed information test protocol, three or more probe stimuli are necessarily needed. But it is hard to acquire three or more probe stimuli, because most of the crime relevant information is opened in investigative situation. In addition, P300-based concealed information test uses oddball paradigm, and oddball paradigm makes imbalance between the number of probe and irrelevant stimulus. Thus, there is a possibility that the unbalanced number of probe and irrelevant stimulus caused systematic underestimation of P300 amplitude of irrelevant stimuli. To overcome the these two limitation of P300-based concealed information test, one-probe P300-based concealed information test protocol is explored with various machine learning algorithms. According to this study, parameters of the modified one-probe protocol are as follows. In the condition of female and male face stimuli, the duration of stimuli are encouraged 400ms, the repetition of stimuli are encouraged 60 times, the analysis method of P300 amplitude is encouraged peak to peak method, the cut-off of guilty condition is encouraged 90% and the cut-off of innocent condition is encouraged 30%. In the condition of two-syllable word stimulus, the duration of stimulus is encouraged 300ms, the repetition of stimulus is encouraged 60 times, the analysis method of P300 amplitude is encouraged peak to peak method, the cut-off of guilty condition is encouraged 90% and the cut-off of innocent condition is encouraged 30%. It was also conformed that the logistic regression (LR), linear discriminant analysis (LDA), K Neighbors (KNN) algorithms were probable methods for analysis of P300 amplitude. The one-probe P300-based concealed information test with machine learning protocol is helpful to increase utilization of P300-based concealed information test, and supports to determine a person's truthfulness and credibility with the polygraph examination in criminal procedure.
Proceedings of the Korean Society of Precision Engineering Conference
/
2004.10a
/
pp.552-555
/
2004
The reliability issue of the probe tip/recording media interface is one of the most crucial concerns in the Atomic Force Microscope (AFM)-based recording technology. In this work, the tribological characteristics of the probe/media interface were investigated by performing wear tests using an AFM. The ranges of applied normal load and sliding velocity for the wear test were 10 to 50nN and 2 to 20$\mu$m/s respectively. The damage of the probe tip was quantitatively as well as qualitatively characterized by Field Emission Scanning Probe Microscope (FESEM) analysis and calculated based on Archard s wear equation. It was shown that the wear coefficient of the probe tip was in the order of 10$^{-4}$ ~ 10$^{-3}$ , and significant contamination at the end of the probe tip was observed. Thus in order to implement the AFM-based recording technology, tribological optimization of the probe/media interface must be achieved.
Proceedings of the Korean Society of Propulsion Engineers Conference
/
2011.11a
/
pp.359-363
/
2011
In this paper, the characteristic of pressures had been analyzed with a series of shapes that are pressure probes used in supersonic wind tunnel. When a performance of supersonic wind tunnel is evaluated, the Mach number is calculated by using the ratio of static pressure in test section wall to total pressure in settling chamber. Also the flow condition can be visualized by schlieren system. However a number of limitations exist to measure pressure of test section due to high speed and boundary layer effect. Therefore a specific pressure probe is needed for evaluating flow condition in test section at a various of positions. In the paper, experiments were conducted in terms of some pitot probes and the results were compared and analyzed.
Transactions of the Korean Society of Mechanical Engineers A
/
v.24
no.4
s.175
/
pp.874-880
/
2000
In this paper, a DC potential drop measurement system was used to find the position of the flaw on a simple thin plate. Four-point probe test was evaluated and used for this study. In the four-point probe test, the more distance between current pins provides the more measurable scope, the less voltage difference, and the more voltage difference rate. In the other hand, the more distance between voltage pins provides the less voltage difference and the less voltage difference rate. An optimized four-point probe was applied to measure the relation between voltage and the relative position of flaw to the probe. The Maxwell 21) simulator was used to analyze the electromagnetic field, and it showed that the analytical result was similar to the experimental result within 11.4% maximum error.
Transactions of the Korean Society of Pressure Vessels and Piping
/
v.7
no.4
/
pp.19-25
/
2011
Steam Generator(SG) tube is an important component of Nuclear Power Plant(NPP), which is the pressure boundary between the primary and secondary systems. The integrity of SG tube has been confirmed by the eddy current test every outage. The eddy current technique adopting bobbin probe is currently the primary technique for the steam generator tubing integrity assesment. The bobbin probe is one of the essential components which consist of the whole ECT examination system and provides us a decisive data for the evaluation of tube integrity. Until now, all of the ECT bobbin probes in Korea which is necessary to carry out inspection are imported from overseas. However, KHNP has recently developed the bobbin probe design technology and transferred it to domestic manufacturers to fabricate the probes. This study has been conducted to establish technical requirements applicable to the steam generator tube inspection using the bobbin probes fabricated by the domestic manufactures. The results have been compared with the results obtained by using foreign probe to identify the availability to the steam generator tube inspection. As a result, it is confirmed that the domestic bobbin probe is generally applicable to SG tube inspection in the NPPs.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.