• Title/Summary/Keyword: Test Installation

Search Result 1,495, Processing Time 0.028 seconds

A study on the Characteristics of the old modules (오래된 모듈의 특성에 관한 연구)

  • Hong, Sa-Keun;Choi, Hong-Kyoo;Yum, Sung-Bae;Song, Young-Joo;Choi, Young-Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.351-354
    • /
    • 2009
  • The solar photovoltaic power generator is more important than other renewable energy. Because The solar photovoltaic power generator has been commercialized. So the solar photovoltaic power plants have been constructed. The photovoltaic module lifetime is estimated about 20 year. But The results can not be trusted Because It did not test in the korea. In this paper, We test the maximum power of three modules used 23 years.

  • PDF

A Basis Study for Life Time Test of MCCB (배선용 차단기 수명평가를 위한 기초 연구)

  • Seo, Jung-Youl;Shin, Hee-Sang;Kim, Oh-Hwan;Kim, Jae-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.439-441
    • /
    • 2009
  • Recently, load circuits and components of customer are various. Therefore failures of ELB(Earth Leakage Breaker) and MCCB(Molded case circuit breakers) are more frequent. Lite time of MCCB even if there is same units differ from environment, condition of operation. FEMCA is a efficiency method of system operation or maintenance for system reliability. We study on FMECA procedures and method. In this paper, we focused on FMECA application to MCCB life time test.

  • PDF

Development of Electric safety monitoring system for reducing the electrical fire at traditional market (재래시장 전기화재 감소를 위한 전기안전감시시스템 개발 연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.259-262
    • /
    • 2009
  • This paper in order to reduce the electric disaster damage which is caused by with electric equipment of traditional market developed the electric safety monitoring system which is suitable in traditional market. With for this did the actual condition investigation about electrical equipment of traditional market and we constructed Test-bed for testing reliability of electric safety monitoring system. Also experiment led in Test-bed and confirmed a stability. This paper following will be used with the data for the reliability security of the electric safe system operation which follows in the traditional market actual proof equipment construction which will be advanced.

  • PDF

A study on the safety LED lamp using internal control gear as the alternative type of fluorescent lamp (형광램프 대체 컨버터 내장형 LED램프의 안전성 확보방안)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • As products using LEDs are developed actively, also there has been large request for LED products that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there is no proper standard that manufacturer can use and test it. As a result manufacturer can't develop retrofit LED lamps and sell it even they have technology. In this study, by analyzing control gear for fluorescent lamp that is currently used in market which is magnetic or electronic ballast, I'd like to develop proper test method by investigating compatibility between all-type control gear and LED retrofit products.

Field Test Study of Photovoltaic Generation System for Medium and Small-Sized Buildings (중소형 건물 태양광발전시스템의 실증 연구)

  • Kim, Eung-Sang;Kim, Seul-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.561-565
    • /
    • 2006
  • The paper presents a method of assessing the adequate tapaclty of photovoltaic generation systems for public buildings based on analysis of load variation patterns of customers. When PV systems are installed for supplying power for the customer load, reverse power relay is required by the guideline to be installed at the point of common coupling with the power network. The suggested method analyzes daily, weekly and monthly load demand of the customer that Irishes PV system installation, and determines the appropriate rating of the PV system for preventing PV generation from exceeding the customer demand. This work is expected to support renewable energy dissemination projects of public organizations.

  • PDF

Analysis Technique of Risk Voltage around Grounding Electrode by New Touch and Step Voltage Measurement Methods (새로운 접촉 및 보폭전압 측정법에 의한 접지전극 주위의 위험전압 분석기법)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.81-86
    • /
    • 2012
  • This paper describes the analysis technique of risk voltage around grounding electrode by new touch and step voltage measurement methods. We have analyzed three techniques for risk voltage measurement, such as footprint-electrode method, test-probe method, and simulated-personnel method. We have selected test-probe method considering applicability of site. In order to reduce error related to the location of the auxiliary electrode, we propose a new approach to perform risk voltage measurement with minimum errors and short auxiliary electrode distances. Field tests were carried out at a grounding grid. It can be concluded that the proposed method will be satisfactory for risk voltage measurement.

Development of the Power Conversion Controller for Electric Vehicle (전기자동차용 전력변환 제어기 개발)

  • Oh, Yong-Seung;Kim, Hee-Jun;Lee, Sang-Taek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.18-25
    • /
    • 2012
  • Recently, the depletion of fossil fuel carbon dioxide emissions due to limitations in the internal combustion engine vehicles is rising concern about electric vehicle. Neighborhood Electric Vehicle(NEV) is maximum speed 60km/h and one day driving distances less than 80km. In this paper, Power Conversion Controller is proposed for Neighborhood Electric Vehicle. To verify the developed Power conversion Controller, Test performed integration test, max load, power density, efficiency. Confirmed that the vehicle can be applied.

The Analysis of Emotion Adjective for LED Light Colors by using Kobayashi scale and I.R.I scale (Kobayashi 스케일과 I.R.I 스케일을 사용한 LED 광색의 형용사 이미지 분석)

  • Baek, Chang-Hwan;Park, Seung-Ok;Kim, Hong-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.10
    • /
    • pp.1-13
    • /
    • 2011
  • The aim of this study is to analyze the emotion adjectives for light emitting diode(LED) light colors using a twofold adjective image scales from Kobayashi and I.R.I. A set of psychophysical experiments using category judgment was conducted in an LED light color simulation system, in order to evaluate each emotion scale coordinate for those test light colors in both adjective image scales. In total, 49 test light colors from a combination of 6 color series were assessed by 15 human observers. As a result, Kobayashi adjective image scale clearly expressed to emotion adjectives of 'Dynamic', 'Casual', 'Chic', 'Cool-casual', 'Modern', and 'Natural' for different hues. In contrast, I.R.I adjective image scale expressed only 2 adjectives of 'dynamic' and 'luxurious' for the all hues.

Improvement and Installation Test of a Power System Simulator (전력계통 해석용 시뮬레이터 성능향상 및 설치시험)

  • Yoon, Y.B.;Kim, T.K.;Kim, K.D.;Jeon, D.H.;Shin, J.H.;Kim, Y.H.;Park, S.W.;Cha, S.T.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.136-139
    • /
    • 2001
  • KEPRI successfully developed and installed RTDS(Real-Time Digital Simulator) during March 2001. The simulator will be used to study interactive simulation of electromagnetic & electromechanical and validation of protective & control systems. In this paper. the authors will present an overview of real-time digital simulator and its characteristic features. Special emphasis will be placed to the installation test results. This paper also addresses some key issues on the accuracy, reliability flexibility and its practical uses for real-time power simulation.

  • PDF

On Installation of Bus Trunk System for Wind Tower (풍력타워용 부스닥트 포설시스템 개발)

  • Lee, Joon-Keun;Kim, Bong-Seok;Park, Seong-Hee;Ahn, Hyung-Joon;Lee, Hee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.330-335
    • /
    • 2012
  • A Bus Trunk System for Wind Tower is introduced. A marine cable has been widely used in wind tower or other offshore structure. However, as the electric load capacity is getting increased, the large number of cable lines should be used to cover such a huge amount of electric capacities, which makes the installation make quite difficult due to the heavy weight and volume of the present cables. On the other hand, by using a single bus trunk system line, the power capacity amount of 16 number of cable can be delivered with significant compactness. However, unlike flexible cable, the bus trunk is relatively stiff which could arise resonance phenomenon in the operating condition of wind tower, therefore, the vibration characteristics of bus trunk should be investigated and verify its long-term reliability during the life time of the wind tower.

  • PDF