• Title/Summary/Keyword: Test Hole

Search Result 864, Processing Time 0.032 seconds

A Study on 4 Point Bending Strength of Carbon/epoxy Face Sheet and Honeycomb Core Sandwich Composite Structure after Open Hole Damage (카본/에폭시 면재 및 허니컴 코어 샌드위치 복합재 구조의 구멍 손상에 의한 4점 굽힘 강도 연구)

  • Park, Hyunbum
    • Composites Research
    • /
    • v.27 no.2
    • /
    • pp.77-81
    • /
    • 2014
  • In this study, it was performed damage assessment and repair of small scale aircraft adopted on composite. This aircraft adopted the sandwich structure to skin of wing. This study aims to investigate the residual strength of sandwich composites with nomex honeycomb core and carbon fiber face sheets after the open hole damage by the experimental investigation. The 4-point bending tests were used to find the bending strength, and the open hole was applied to introduce the simulated damage on the specimen. The bending strength test results after open hole were compared with the results of no damaged specimen test. In addition, The damaged composite structure was repaired using external patch repair method after removing damaged area. After that, this study presents comparison results of the experimental investigation between the damaged and the repaired specimen. It was found that the bending strength of repaired specimen was recovered up to 95% of undamaged specimen.

Development of 3-Dimensional Stress Measurement System by Bore hole Bottom Deformation Method (공저변형법에 의한 3차원응력측정 시스템의 개발)

  • Lee, Ki-Ha;Ishijima, Yoji;Fujii, Yoshiaki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.34-41
    • /
    • 2006
  • A 3-dimensional stress measurement system based on the bore hole bottom deformation method, which is one of the stress relief methods, was developed. A pilot bore hole is drilled from the bottom of a bore hole and the stress meter is inserted into the pilot bore hole in the method. The bore hole is advanced as an over coring and the deformations in seven directions are measured by cantilever type-sensors. Using the cantilever type-sensors saves time for hardening of glue. No cable connection between the stress meter and a data logger is necessary since a compact data logger is installed in the stress meter. The accuracy of the stress meter was confirmed by a biaxial test for a Shikotsu welded tuff block although in-situ tests have not been carried out yet.

  • PDF

A Study on the Effect of the Stop-hole on the Fatigue Crack Growth Rates in Tensile Members (인장부재(引張部材)에 뚫은 Stop-hole 이 피로균열성장율(疲勞龜裂成長率)에 미치는 영향(影響)에 관한 연구(研究))

  • Chang, Dong Il;Jung, Kyoung Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.4
    • /
    • pp.115-124
    • /
    • 1987
  • Stop-hole method is one of the conventional methods for the temporary repair or reinforcement of the member in the case that the structural steel member has a fatigue crack. In this study, the stop-hole method. have been estimated quantitatively in terms of survival life time of the side edge cracked specimen. For this purpose, fatigue tests have been performed on the test specimens and the fatigue crack growth rates of the structural steel (SS41) members have been measured under load of constant amplitude. The results of this experiment show that it is desirable to use the stop-hole method before the crack reaches the region of elasto-plastic behaviour.

  • PDF

Hole pattern 형성에 따른 금속/PET sheet의 인장 시 저항변화

  • Choe, Yeong-Jun;Gwon, Na-Hyeon;Jo, Yeong-Rae
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.37.1-37.1
    • /
    • 2009
  • 최근 휘어짐이 가능한 flexible display의 개발이 활발히 진행됨에 따라 OLED(organic light emitting diode)의 발전 가능성은 커지고 있다. 하지만 cathode 재료인 Cr, Al등은 tensile 또는 bending에 취약하다. 따라서 본 연구에서는, 인장시험용 아령모형의 PET($125\;{\mu}m$) 필름에 Al, Cr, Cr+Al을 각각 코팅하고 부분적으로 hole을 patterning함으로써 인장 시 미소크랙의 발생을 감소시켜 전기저항(R) 변화를 최소화하는 패턴형상을 design하고 세 가지 금속의 전기저항 변화를 통해 좀 더 우수한 flexible display용 금속을 찾는데 그 목적이 있다. 전극에 형성된 미세패턴의 영향과 패턴 된 hole size에 따른 전기저항의 변화를 알아보기 위해 hole size는 $50\;{\mu}m$, $30\;{\mu}m$, $10\;{\mu}m$로 제작하였고 각각의 금속막에 patterning하였다. 제작된 시편을 인장시험 장치에 설치 후 2mm/min의 속도로 인장응력을 가하면서 Load의 증가에 따른 금속막의 전기저항($\bigtriangleup$R)을 동시동작으로 측정하였다. 실험결과 인장시험 시 저항변화는 Cr이 짧은 시간에 가장 급격하게 변하였으며 다음으로 Cr+Al, Al순 이였다. 또한, hole size의 크기에 따른 전기저항의 변화는 $50\;{\mu}m$ size의 hole을 pattern한 시편이 가장 안정한 저항 변화를 보였다.

  • PDF

An Experimental Study on Detection of Defects in Weldzone (용접부 결함 검출에 관한 실험적 연구)

  • 남궁재관
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.56-63
    • /
    • 2003
  • In this study, an automatic ultrasonic testing system is used to detect the defects of the natural flaw test specimen and of the artificial flaw test specimen. We evaluate the detection performance of the acceptance standard for the natural flaw test specimen and of the acceptance standard for the artificial flaw test specimen. We also study the potential problems of those acceptance standards. The results indicate that the acceptance standard for the detection of defects in weldzone is good then the sensitivity correction is performed and that we must clearly specify special check points of the acceptance standard for the system in use.

Reliable Evaluation of Dynamic Ground Properties from Cross-hole Seismic Test using Spying-loaded Lateral Impact Source (스프링식 횡방항 발진 크로스홀 탄성파 시험을 통한 지반 동적 특성의 합리적 산정)

  • Sun, Chang-Guk;Mok, Young-Jin;Chung, Choong-Ki;Kim, Myoung-Mo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.4 s.50
    • /
    • pp.1-13
    • /
    • 2006
  • Soil and rock dynamic properties such as shear wave velocity $(V_s)$, compressional wave velocity $(V_p)$ and corresponding Poisson's ratio (v) are very important geotechnical parameters in predicting deformational behavior of structures as well as practicing seismic design and performance evaluation. In an effort to measure the parameter efficiently and accurately, various bore-hole seismic testing techniques have been, thus, developed and used during past several decades. In this study, cross-hole seismic testing technique which is known as the most reliable seismic method was adopted for obtaining geotechnical dynamic properties. To perform successfully the cross-hole test for rock as well as soil layers regardless of the ground water level, spring-loaded source which impact laterally a subsurface ground in vertical bore-hole was developed and applied at three study areas, which contain four sites composed of two existing port sites and two new LNG storage facility sites. The geotechnical dynamic properties such as $V_s,\;V_p$ and v with depth from the soil surface to the engineering and seismic bedrock were efficiently determined from the laterally impacted cross-hole seismic tests at study sites, and were provided as the fundamental parameters for the seismic performance evaluation of the existing ports and the seismic design of the LNG storage facilities.

Evaluation of dynamic ground properties using laterally impacted cross-hole seismic test (횡방향 발진 크로스홀 탄성파 시험을 이용한 지반의 동적 특성 평가)

  • Mok Young-Jin;Sun Chang Guk;Kim Jung-Han;Jung Jin-Hun;Park Chul-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.09a
    • /
    • pp.155-175
    • /
    • 2005
  • Soil and rock dynamic properties such as shear wave velocity (VS), compressional wave velocity (VP) and corresponding Poisson's ratio ( v ) are very important geotechnical parameters in predicting deformational behavior of structures as well as practicing seismic design and performance evaluation. In an effort to measure the parameter efficiently and accurately, various bore-hole seismic testing techniques have been, thus, developed and used during past several decades. In this study, cross-hole seismic testing technique which is known as the most reliable seismic method was adopted for obtaining geotechnical dynamic properties. To perform successfully the cross-hole test for rock as well as soil layers regardless of the ground water level, spring-loaded source which impact laterally a subsurface ground in vertical bore-hole was developed and applied at three study areas, which contain four sites composed of two existing port sites and two new LNG storage facility sites. The geotechnical dynamic properties such as VS, VP and v with depth were efficiently determined from the laterally impacted cross-hole seismic tests at study sites, and were provided as the fundamental parameters for the seismic performance evaluation of the existing ports and the seismic design of the LNG storage facilities.

  • PDF

Surveying and the Ergonomic Analysis of Eye Dominance (주시(Eye Dominance)에 관한 조사 및 인간공학적 분석)

  • 정화식
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.2
    • /
    • pp.79-89
    • /
    • 2004
  • It is known that most people have a dominant eye, even though each of their two eyes in isolation may provide equal vision. In this study, 600 Korean male and female subjects aging from 11 to 78 were selected to investigate the various statistics about eye dominance( whether the left or right eye is dominant} in Korean and their employment characteristics of preferred eye in sighting diverse things. A simple sighting test was applied such that subjects are requested to aim a distance target through small hole in B4 sized paper with both eyes open. The dominant eye was determined by alternate occlusion: when viewing with the dominant eye into the hole is aligned with the target, whereas when viewing with the other eye into the hole appears offset to one side. The descriptive statistics showed that 83.7% and 16.3% were right and left eye dominant respectively. Moreover, various statistical analysis revealed that general tendency of eye dominance was varied by age, gender, hand dominance and visual acuity. It was thus found from these results that people sighting their eyes differently depending on the eye dominance when they sight things.

Effects of a Digital Pegboard Training Program With Visual and Auditory Feedback on Hand Function and Visual Perception in Patients With Stroke (시각, 청각 피드백을 이용한 디지털 페그보드 훈련 작업치료 프로그램이 뇌졸중 환자의 손 기능 및 시·지각에 미치는 영향)

  • Hong, Jang-Woo;Yoo, Chan-Uk;Gang, Mi-Yeong;Chang, Ki-Yeon
    • Therapeutic Science for Rehabilitation
    • /
    • v.11 no.4
    • /
    • pp.85-97
    • /
    • 2022
  • Purpose : This study aimed to investigate the effects of a digital pegboard training program with visual and auditory feedback on hand function and visual perception in stroke patients. Methods : Twenty two participants were randomly assigned to an experimental or control group. The experimental group received training using a digital pegboard training program with visual and auditory feedback (n=11), while traditional occupational therapy was administered to the control group (n=11). Hand function was assessed before and after the intervention using the Nine-Hole Peg Test and manual function test (MFT), while visual perception was assessed using the Motor-Free Visual Perception Test-3rd edition (MVPT-3). Results : Following the intervention, both the experimental and control groups showed significant improvements in performance in the Nine-Hole Peg Test and MVPT-3 (p<.05). The improvement on both tests was significantly greater in the experimental group than in the control group (p<.05). Conclusion : The results suggest that digital pegboard training with visual and auditory feedback may improve hand function and visual perception in stroke patients. Therefore, this intervention can be effective in occupational therapy to aid the recovery of stroke patients.

Change of Strength of High-Strength Bolted Connection Depending on Standard and Over Bolt Hole (표준공과 과대공을 갖는 고장력볼트 접합부의 강도변화)

  • Yang, Seung-Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.605-612
    • /
    • 2012
  • A tension member that has a high-strength bolt fastened to a standard bolt hole increases structural resistance but causes problems from workability or economic perspectives. In this research, a total of 28 samples that have standard and over bolt holes as the tension member's high-strength bolted connection were made and a tension test was conducted. The change of strength of the connection has been confirmed by comparing the tension load of standard and over bolt hole samples obtained from the test results with the design strength due to net section and end distance. Samples made with over bolt holes had a lighter tension load than that of samples made with standard bolt holes, exceeded the design strength of present design standards, and although decrease in strength was inevitable due to the over bolt hole, their safety was satisfactory.