• Title/Summary/Keyword: Test Accuracy

Search Result 4,922, Processing Time 0.037 seconds

High-Accuracy Coastdown Test Method by Distance-Time Measurement: II. Development of a Short Distance Method and its Evaluation (거리·시간 측정에 의한 고정도 타행시험법: II. 단거리 방법의 개발 및 시험)

  • Hur, N.G.;Ahn, I.K.;Petrushov, V.A.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.3
    • /
    • pp.1-8
    • /
    • 1995
  • In the companion paper of the present paper, a coast down test method to determine the resistance forces on running vehicle based on the distance-time measurement was explained along with the suggestions to improve its accuracy and testing methodology. In the present paper some of the suggestions discussed previously are implemented and actually road tested to see the applicability of the improved method(short distance method) in the field. From the results. it is shown that the short distance method which requires only 600m long proving ground road gives at least comparable results on the accuracy compared to the original S-t method which requires 2000m. It is hoped that the present method be further refiend to give more accurate results.

  • PDF

A NOVEL 3D SCAN METHOD TO QUANTIFY TEETH WEAR (3-Dimensional scan을 이용한 치아 마모량 측정 방법에 관한 연구)

  • Kim Seung-June;Choi Dae-Gyun;Kwon Kung-Rock;Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Statement of problem : Tooth wear is physiological phenomenon. Ninety-seven percent of normal people have tooth wear and about 7% has pathologic teeth wear. If we know the amount of tooth surface loss caused by pathologic tooth wear, we may restore it ideally Purpose : Recently measurement of tooth wear by using 3D scan has been increasing. Therefore, we need to know how accurate 3D scan is. Past accuracy test on 3D scan was about linear change, but as we know that tooth wear is volume change. Thus, the purpose of this study is to know how accurate 3D scan is. Material and Methods : For accuracy test of 3D scanner volume values measured by 3D scanner and micro-balance were compared. For test I, preliminary, 3 ball samples and 3 circular cones were made with pattern resin. For test II, 10 teeth shape rubber samples were used. Results and Conclusion : 1. The result of the accuracy test on 3D scan with 3 ball samples and 3 circular cones made of pattern resin has no significant difference(p<0.05). 2. The result of the accuracy test on 3D scan with 10 samples of tooth shape rubber has no significant difference (p<0.05). As a result, we may concluded the analysis of quantifying tooth wear used by 3D scan is useful in the clinic.

A Study of Three-dimensional evaluation of the accuracy of resin provisional restorations fabricated with the DLP printer (DLP 프린터로 제작된 레진 임시수복물의 3차원적 정확도 평가)

  • Kang, Wol;Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of the DLP 3D printer by conducting 3-dimensional assesment of resin provisional restorations. Methods: The first premolar of the maxillary was prepared for the abutment. The abutment was scanned by using a scanner. The provisional restoration was designed by using CAD software. A total of 16 resin provisional restorations were produced using ZD200 and Veltz DLP 3D printer. Scanning was done of resin provisional restorations and 3-dimensional measurement was conducted for accuracy. The mean (SD) of RMS was reported for each group. Independent t-test was used to assess the statistical significance of the results. All analyses were done using SPSS 22.0. Results: The mean ± SD of RMS value for the accuracy of the resin provisional restorations that was fabricated by using ZD200 and Veltz DLP 3D printer were 50.85.±4.64㎛ and 70.33±6.31㎛. Independent t-test showed significant differences between groups(p<0.001). Conclusion: The resin provisional restorations made with DLP 3D printers showed clinically acceptable accuracy.

Analysis of overlap ratio for registration accuracy improvement of 3D point cloud data at construction sites (건설현장 3차원 점군 데이터 정합 정확성 향상을 위한 중첩비율 분석)

  • Park, Su-Yeul;Kim, Seok
    • Journal of KIBIM
    • /
    • v.11 no.4
    • /
    • pp.1-9
    • /
    • 2021
  • Comparing to general scanning data, the 3D digital map for large construction sites and complex buildings consists of millions of points. The large construction site needs to be scanned multiple times by drone photogrammetry or terrestrial laser scanner (TLS) survey. The scanned point cloud data are required to be registrated with high resolution and high point density. Unlike the registration of 2D data, the matrix of translation and rotation are used for registration of 3D point cloud data. Archiving high accuracy with 3D point cloud data is not easy due to 3D Cartesian coordinate system. Therefore, in this study, iterative closest point (ICP) registration method for improve accuracy of 3D digital map was employed by different overlap ratio on 3D digital maps. This study conducted the accuracy test using different overlap ratios of two digital maps from 10% to 100%. The results of the accuracy test presented the optimal overlap ratios for an ICP registration method on digital maps.

A Study on the Development and Precise Performance Test of a Screw Type Flowmeter (스크류 유량계의 개발 및 정밀 성능평가에 관한 연구)

  • Hwang, Jong-Dae;Oh, Ji-Young;Jung, Yoon-Gyo;Lee, Sang-Ryul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.87-95
    • /
    • 2009
  • This research introduces the efficient modeling and manufacturing method using reverse engineering combined with rotational simulation of a pair of screw and mill-turn machining realized a proposed NC program. Because previously developed model had insufficient flow measuring accuracy, we considered that matter in the aspect of method of modeling and performance test. For that reason we modified the modeling which could minimize a gab between male and female screw, and developed precise tester which consists of constant tank, flowmeter and load cell, etc., and then conducted the test for defining characteristic and accuracy of flowmeter and repeated same test 5-times. Consequently we could obtain satisfied measuring accuracy and reproducibility indicated in the catalog of master model. Hence we give our conclusion as to the validity of developing accurate screw type flowmeter using the proposed process such as reverse engineering, mill-turn machining and precise performance test.

The Evaluation of Distance Accuracy and The Test Target Manufacturing of A Terrestrial Laser Scanner (TLS용 테스트 타깃의 개발과 거리측정 정확도 검증)

  • Lee, In-Su;Tcha, Dek-Kie;Suh, Ho-Suhng
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.3
    • /
    • pp.279-285
    • /
    • 2012
  • Albeit the use of terrestrial 3D laser scanner (TLS) in the parts of landslide monitoring, cultural heritage documentation, civil engineering, urban engineering, etc. is increasing more and more, there is no international standardization regulation about the accuracy evaluation of the geometric element values, target, instrument calibration and test procedures, etc. Accordingly, this study deals with the manufacturing of TLS performance test target and the evaluation of TLS distance measurement and shows its suitability as the test target.

A Study on Measuring of Motion Accuracy of NC Machine Tools(No.1) -about Measuring of Linear Cycle Positioning Accuracy of NC Lathe (NC 공작기계의 운동정도 측정에 관한 연구(제1보) - NC 선반의 직선 사이클 위치결정정도 측정에 관하여 -)

    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.1
    • /
    • pp.82-88
    • /
    • 1998
  • It is very important to test linear cycle positioning accuracy of NC lathes as it affect all other machines machined by them in industries. For example, if the linear positioning accuracy of x or z-axis directions is bad, the size of works will be wrong and the change-ability will be bad in the assembly of machine parts. In this paper , measuring systems are organized to measure linear displacement of ATC(Automatic tool changer) of NC lathe using laser interferometer, magnescale and tick pulses coming out from computer in order to get data at constant time intervals from the sensors, And each set of data gotten from test is expressed to a plots by computer treatment and the results of linear positioning error motion is estimated to numerics by statistical treatments.

  • PDF

A Study of Test Method for Position Reporting Accuracy of Airborne Camera (항공기 탑재용 카메라 위치출력오차 측정방안 연구)

  • Song, Dae-Buem;Yoon, Yong-Eun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.646-652
    • /
    • 2013
  • PRA(Position Reporting Accuracy) for EO/IR(Electro-Optic/Infrared) airborne camera is an important factor in geo-pointing accuracy. Generally, rate table is used to measure PRA of gimbal actuated camera like EO/IR. However, it is not always possible to fix an EUT(Equipment for Under Test) to rate table due to capacity limit of the table on the size and weight of the object(EUT). Our EO/IR is too big and heavy to emplace on it. Therefore, we propose a new verification method of PRA for airborne camera and assess the validity of our proposition. In this method we use collimator, angle measuring instrument, 6 dof motion simulator, optical surface plate, leveling laser, inclinometer and poster(for alignment).

A Study on the Performance Evaluation of Heavy Duty Handling Robot using Laser Tracker (초 중량물 핸드링 로봇의 성능평가에 관한 연구)

  • Ko, Haeju;Jung, Yoongyo;Shin, Hyeuk;Ryou, Han-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.3
    • /
    • pp.1-7
    • /
    • 2010
  • The aim of this research is to evaluate movement and path characteristics of developed heavy duty handling robot using laser tracker(API T3) according to the ISO 9283 robot performance evaluation criteria. As carry out 3D modeling and simulation using CATIA, a test cube was set up to select moving and measuring range of robot. Performance test for pose and distance accuracy, path and path velocity accuracy under payload zero and 440kgf was accomplished. The resulted output data show the reliability of the developed robot.

A Study on the Plan Photogrammetry for Clothing Design (피복구성학적 인체계측방법에 관한 연구 - 평면사진계측방법을 중심으로 -)

  • 박찬미;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.5 no.1
    • /
    • pp.151-164
    • /
    • 1997
  • This study pursues the problems of plan photogrammetry which is widely used in somatotyping at present, and find out a method which can improve accuracy of measurement on the basis of principles and mechanisms of photography-the basic foundation of the photographic analysis methods. As a result, this study proposes a new method which is based on the reference point method and perspective coordinate system. And the test measurement was operated to compare the measurement accuracy of the proposed method and the method based on reference grid screen method and perpendicular coordinate system which is commonly used at present. The result of this test measurement showed that the proposed method has higher accuracy. Two reasons can be pointed out for the improvement of measuring accuracy. The first reason is that the proposed perspective coordinate system reduces the perspective distortion of photography. And second reason is that measuring points can be closely placed to the scale and coordinate reference plan of measurement by the proposed reference point method which make possible to place measuring object (or person) at the center of scale and coordinate reference plan by utilizing reference points of measurement in the three dimensional space not on screen.

  • PDF