• Title/Summary/Keyword: Terminal Operation

Search Result 689, Processing Time 0.028 seconds

A Signal Readout System for CNT Sensor Arrays (CNT 센서 어레이를 위한 신호 검출 시스템)

  • Shin, Young-San;Wee, Jae-Kyung;Song, In-Chae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.9
    • /
    • pp.31-39
    • /
    • 2011
  • In this paper, we propose a signal readout system with small area and low power consumption for CNT sensor arrays. The proposed system consists of signal readout circuitry, a digital controller, and UART I/O. The key components of the signal readout circuitry are 64 transimpedance amplifiers (TIA) and SAR-ADC with 11-bit resolution. The TIA adopts an active input current mirror (AICM) for voltage biasing and current amplification of a sensor. The proposed architecture can reduce area and power without sampling rate degradation because the 64 TIAs share a variable gain amplifier (VGA) which needs large area and high power due to resistive feedback. In addition, the SAR-ADC is designed for low power with modified algorithm where the operation of the lower bits can be skipped according to an input voltage level. The operation of ADC is controlled by a digital controller based on UART protocol. The data of ADC can be monitored on a computer terminal. The signal readout circuitry was designed with 0.13${\mu}m$ CMOS technology. It occupies the area of 0.173 $mm^2$ and consumes 77.06${\mu}W$ at the conversion rate of 640 samples/s. According to measurement, the linearity error is under 5.3% in the input sensing current range of 10nA - 10${\mu}A$. The UART I/O and the digital controller were designed with 0.18${\mu}m$ CMOS technology and their area is 0.251 $mm^2$.

Development of Tacho Generator for Application of Anti-aircraft Weapon System (대공무기체계 적용을 위한 타코제너레이터 개발)

  • Byun, Kisik;Park, Jun Young;Cho, Sung-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.174-180
    • /
    • 2020
  • This paper presents the development of a tacho generator that is applicable to a DC motor for anti-aircraft weapon systems. In general, devices such as tacho generators and resolvers are used as feedback devices for controlling DC motors. A tacho generator with a wide operating temperature range was developed, which has robust characteristics against shock loads and vibrations according to the operational characteristics of anti-aircraft weapon systems. The target specifications were set based on the requirements of the tacho generator currently in operation. A rotor coupled to the shaft of the motor and a stator coupled to the housing of the motor were then designed and manufactured. The inductance was 31.0 mH, the terminal resistance was 147.7 ohms, and the rotational measurement factor was satisfactory under both normal operation and operating conditions after the maximum speed for the standard of 9.500 ± 0.475 V/krpm. In addition, the environmental suitability of the applied equipment was confirmed through the rate of change in unit temperature, and it was found that the temperature characteristics were all within 0.03 %/℃.

High safety battery management system of DC power source for hybrid vessel (하이브리드 선박 직류전원용 고 안전 BMS)

  • Choi, Jung-Leyl;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.635-641
    • /
    • 2016
  • In order to drive a hybrid propulsion device which combines an engine and an electric propulsion unit, battery packs that contain dozens of unit cells consisting of a lithium-based battery are used to maintain the power source. Therefore, it is necessary to more strictly manage a number of battery cells at any given time. In order to manage battery cells, generally voltage, current, and temperature data under load condition are monitored from a personal computer. Other important elements required to analyze the condition of the battery are the internal resistances that are used to judge its state-of-health (SOH) and the open-circuit voltage (OCV) that is used to check the battery charging state. However, in principle, the internal resistances cannot be measured during operation because the parallel equivalent circuit is composed of internal loss resistances and capacitance. In most energy storage systems, battery management system (BMS) operations are carried out by using data such as voltage, current, and temperature. However, during operation, in the case of unexpected battery cell failure, the output voltage of the power supply can be changed and propulsion of the hybrid vehicle and vessel can be difficult. This paper covers the implementation of a high safety battery management system (HSBMS) that can estimate the OCV while the device is being driven. If a battery cell fails unexpectedly, a DC power supply with lithium iron phosphate can keep providing the load with a constant output voltage using the remainder of the batteries, and it is also possible to estimate the internal resistance.

A Study of High-Precision Time-Synchronization for TDoA-Based Location Estimation (TDoA 기반의 위치 추정을 위한 초정밀 시각동기에 관한 연구)

  • Kim, Jae Wan;Eom, Doo Seop
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.2 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • Presently, there are many different technologies used for position detection. However, as signal-receiving devices operating in different locations must detect the precise position of objects located at long distances, it is essential to know the precise time at which an object's or a user's terminal device sends a signal. For this purpose, the existing time of arrival (ToA) technology is not sufficiently reliable, and the existing time difference of arrival (TDoA) technology is more suitable. If a TDoA-based electric surveillance system and other tracking devices fail to achieve precise time-synchronization between devices with separation distance operation, it is impossible to obtain correct TDoA values from the signals sent by the signal-receiving devices; this failure to obtain the correct values directly affects the location estimation error. For this reason, the technology for achieving precise time synchronization between signal-receiving devices in separation distance operation, among the technologies previously mentioned, is a core technology for detecting TDoA-based locations. In this paper, the accuracy of the proposed time synchronization and the measurement error in the TDoA-based location detection technology is evaluated. The TDoA-based location measurement error is significantly improved when using the proposed method for time-synchronization error reduction.

The Results of Surgical Treatment of Comminuted Fractures of Distal humerus (원위 상완골 분쇄 골절의 수술적 치료 결과)

  • Cho Nam-Su;Park Sung-Woo;Jung Ki-Yoen;Rhee Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.8 no.2
    • /
    • pp.97-104
    • /
    • 2005
  • Purpose: To report the results of surgical treatment of comminuted fractures of distal humerus and to identify factors that affect the results. Materials and Methods: Thirty-two patients who were treated with open reduction and internal fixation for comminuted fracture of distal humerus were enrolled. According to the AO classification, A2.3 was 1 case, A3.2, 2 cases, A3.3, 8 cases, B1.3, 1 case, B2.3, 1 case, C2.2, 5 cases, C2.3, 4 cases, C3.2, 3 cases and C3.3, 7 cases. As fixation technique, 17 cases were fixed by double plates, 4 cases by only K-wires, 4 cases by only screws, 3 cases by K-wires and screws and 4 cases by one plate and screws. The mean age at the time of the operation was 49 years(range, $19{\sim}77$ years). The mean follow-up period was 16 months(range, $8{\sim}51$ months). Results: At the last follow-up, the mean maximum flexion was $116.4^{\circ}\;(range,\;85{\sim}140^{\circ})$ and the mean loss of terminal extension was $11.8^{\circ}\;(range,\;0{\sim}40^{\circ})$. The average Mayo elbow performance score was $91.4^{\circ}\;(range,\;55{\sim}100^{\circ})$. Overall 29 cases(91%) showed good to excellent results. The mean range of motion of extraarticular and intraarticular fracture group was $105.5^{\circ}\;(range,\;65{\sim}140^{\circ})$ and $104^{\circ}\;(range,\;55{\sim}140^{\circ})$, respectively. The average elbow score of both groups was$93^{\circ}\;(range,\;70{\sim}100^{\circ})$ and $90.7^{\circ}\;(range,\;55{\sim}100^{\circ})$. Over 90% showed more than good results. 30 cases(94%) showed complete bony union but two cases, nonunion. One case of the nonunion cases underwent replating with bone graft as revision surgery and total elbow arthroplasty was performed in the other case. At the last follow-up, 27 patients(84.4%) showed subjective satisfaction. Conclusion: Open reduction and internal fixation with appropriate surgical technique for comminuted fractures of distal humerus showed good results, which were not affected by age at the time of operation, fixation methods and anterior transposition of the ulnar nerve. Transolecranon approach may be considered as good choice for intraarticular comminuted fractures of distal humerus.

Neuroprotective Effects of Haein-tang(Hairen-tang) on Decrease of Short-term Memory and Apoptosis in Dentate Gyrus of the Gerbils with Transient Global Ischemia (해인탕이 뇌허혈 유발 모래쥐의 단기기억력 감퇴와 치상회 세포사멸에 미치는 효과)

  • Park, Jung-Chul;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.2
    • /
    • pp.1-13
    • /
    • 2011
  • Objectives : We investigated the effect of Haein-tang(Hairen-tang) on short-term memory and apoptosis in dentate gyrus of the gerbils with transient global ischemia. Methods : For the induction of cerebral ischemia model in mice, common carotid arteries of gerbils were occluded with aneurysm clips for 5 min. One day after operation, Haein-tang(Hairen-tang) was administrated orally injected once a day for 15 consecutive days. Gerbils were randomly divided into four group(n=10 in each group): sham-operation group, ischemia-induction group, ischemia-induction and 50 mg/kg Haein-tang(Hairen-tang)-treated group, ischemia-induction and 100 mg/kg Haein-tang(Hairen-tang)-treated group, and ischemia-induction and 200 mg/kg Haein-tang(Hairen-tang)-treated group. The effect of Haein-tang(Hairen-tang) on memory function was investigated by using step-down avoidance task. Apoptosis was confirmed by terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling(TUNEL) staining and immunohistochemistry for caspase-3. Western blot analysis for the expressions of Bax and Bcl-2 protein was also conducted. Results : 1. Haein-tang extract significantly enhanced short-term memory in step-down avoidance task and 100 mg/kg, 200 mg/kg Haein-tang-treated group. 2. Haein-tang extract significantly suppressed TUNEL-positive cells after transient global ischemia and 50 mg/kg, 100 mg/kg, 200 mg/kg Haein-tang-treated group. 3. Haein-tang extract significantly increased caspase-3 positive cells in the hippocampal dentate gyrus after transient global ischemia and 50 mg/kg, 100 mg/kg, 200 mg/kg Haein-tang-treated group. 4. Haein-tang extract significantly decreased Bax protein expressions in the hippocampus after transient global ischemia and 100 mg/kg, 200 mg/kg, Haein-tang-treated group. Haein-tang extract significantly increased Bcl-2 protein expressions in the hippocampal dentate gyrus after transient global ischemia and 50 mg/kg, 100 mg/kg, 200 mg/kg, Haein-tang-treated group. Haein-tang extract significantly decreased Ratio of Bax protein to Bcl-2 protein in the hippocampus after transient global ischemia and 100 mg/kg, 200 mg/kg Haein-tang-treated group. Conclusions : While Haein-tang(Hairen-tang) treatment improved short-term memory by suppressing on ischemia-induction apoptosis. In the present study, Haein-tang(Hairen-tang) shows protective effect on transient global ischemia.

A Systematic Approach to Port related Problems An Analysis on the Actual Condition of physical Distribution System of Pusan port (항만관련문제의 시스템적 고찰 부산항 물류시스템의 실태분석)

  • Lee Cheol-Yeong;Moon Seong-Hyeok
    • Journal of Korean Port Research
    • /
    • v.2 no.1
    • /
    • pp.7-28
    • /
    • 1988
  • From the viewpoint of physical distribution, the port transport process can be regarded as a system which consists of various subsystems such as navigational aids, quay handling, transfer, storage, information If management, and co-ordination with inland transport. The handling productivity of this system is determined by the production level of the least productive subsystem. So, a productivity analysis on the flow of cargoes through each subsystem should be made in order to achieve efficient port operation. The purpose of this paper is to analyze the productivity of each subsystem in Pusan port, and to bring forward problems and finally to draw up plans for their betterment. Analyzed results on the productivity of each subsystem are as follows, i) It is known that the number of tugs with low HP should be increased by a few, the number of tugs with medium HP is appropriate, and the number of tugs with high HP is in excess of that necessary. ii ) In the case of container cargoes, it is found that the transfer and storage systems in BCTOC have the lowest handling capability, with a rate of $115\%$, leading to bottle-necks in the port transport system, while the handling rate of the storage and quay handling systems in general piers is in excess of the inherent capability. iii) In the case of the principal seaborne cargoes passing through general piers, there is found to be a remarkable bottle-neck in the storage system. In the light of these findings, both the extension of storage capability and the extension of handling productivity are urgently required to meet the needs of port users. Therefore, iv) As a short-term plan, it is proposed that many measures such as the reduction of free time, the efficient application of ODCY, etc must be brought in and v) In the long-trun, even though the handling capability will accommodate an additional 960,000 TEU in 1991, the scheduled completion date of the third development plan of Pusan port, insufficiency of handling facilities in the container terminal is still expected and concrete countermeasures will ultimately have to be taken for the port's harmonious operation. In particular, the problem of co-ordination with inland transport and urban traffic should be seriously examined together in the establishment of the Pusan port development. As a method of solving this, vi) It is suggested that Pusan port (North port) should be converted into an exclusive container ternimal and overall distribution systems to the other ports for treating general cargoes must be established. vii) And finally, it is also proposed that the arrival time (cut-off time) of influx cargoes for exports such as general merchandise and steel product should be limited, with a view to securing cargoes suitable for the operational capability of BCTOC.

  • PDF

The Study of Usability Evaluation in the GUI of Mobile Computing - Based on Benchmark Testing in the interface design of WIPI (Mobile Computing의 GUI 개발에 있어 사용성 평가 연구 - WIPI 인터페이스 디자인을 위한 Benchmark Testing을 중심으로 -)

  • 정봉금;송연승
    • Archives of design research
    • /
    • v.17 no.1
    • /
    • pp.49-62
    • /
    • 2004
  • Due to the recent surge of wireless Internet and concurrent development of the end user terminal devices having standardized graphical user interface(GUI) and unified operation mechanism for better interactivity in information representation and ease of use, various efforts on the improvement of GUI is widely recognized as one of the key factors that will usher in the next stages of the wireless Internet for the users. Especially, improved usability along with unique visual effect are considered to be the key elements for GUI considering the rapid improvement of the resolution and color on the end user handset devices; thus, the study and research on the subject of GUI is expected to increase along with the wireless Internet using smart phones. User interface of the wires Internet end user handsets will have a definite and significant effect on the user interaction as well as productivity. Domestically, wireless Internet service providers and GUI design companies are making various efforts in producing a common GUI models for standardized operation scheme and improved graphical display capabilities of the hand phones, PDAs and smart phones. In the study, Nokia 3650 model and Microsoft Orange SPV model were chosen as test devices for usability comparison and data collection to collect directional benchmark data in developing next generation smart phone user interface integrating PDAs and phones. The mail purpose of this study is to achieve the most efficient user accessibility to WAP menu through intensive focus on developing WIPI WAP menu having most effective usability for the users in their twenties and thirties. The result of this study can also be used as the base research materials for WAP service development, VM browser development and PDA browser development. The result of this study along with the evaluation model is expected to provide effective analysis materials on the subject of user interface to the developers of the wireless Internet user devices, GUI designers and service planners while short listing key factors to consider in developing smart phones therefore serving as the GUI guideline of WIPI phones.

  • PDF

Design of EUT test equipment for EMC Testing (EMC 시험을 위한 EUT 시험장비 설계)

  • Hong-Rak Kim;Youn-Jin Kim;Seong-Ho Park;Man-Hee Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.4
    • /
    • pp.35-40
    • /
    • 2023
  • For the EMC test, the radiation characteristics and immunity characteristics of the EUT are measured under the condition that the EUT maintains its normal operation. For normal operation of the EUT, it is necessary to operate the EUT and monitor its status through separate equipment outside the anechoic chamber. External equipment operates and monitors the EUT through various communications such as 1553B communication, RS-485 communication, and Ethernet communication. At this time, external equipment can transmit noise through the communication line. This noise is transmitted to the LISN through the connected power cable and measured. It is also radiated through the connection terminal to the LISN. In this case, the communication line is the power line It should be designed so that noise is not transmitted through electromagnetic isolation as much as possible. In addition, noise from external equipment must be suppressed as much as possible from entering the chamber through the communication line. In this paper, external EUT test equipment applied for EMC test It explains the considerations in the design and manufacture of the design and explains the satisfaction of the design through tests including CE and RE.

Anaerobic digestion for food wastewater using HADS Pilot Plant and analysis of microbial community in the digester (HADS Pilot Plant를 이용한 음폐수의 혐기성 소화 및 미생물 군집 변화 분석)

  • Ju, Dong-Hun;Lee, Jung-Min;Park, Seong-Bum;Sung, Hyun-Je;Bae, Jae-Sang;Sang, Byoung-In
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.2
    • /
    • pp.76-83
    • /
    • 2010
  • We(Hansol EME Co. Ltd.) proceeded anaerobic digestion test for domestic food wastewater applying to two operating method for increasing of OLR. The methods are as follows. One was the rapidity operating method which was increasing the OLR continuously and rapidly and the other was the terraced operating method which was increasing the OLR having adaptation period for each step. As a result of this tests, the ratio of VFA/Alkalinity of the process was very unstable under the rapidity operating method then the volume of produced biogas was dramatically decreased. However the process was shown stable performance under the terraced operating method maintaining the ratio of VFA/Alkalinity less than 0.4. Also, the process was performing the biogas recovery of $0.8Nm^3/kgVS_{rem}/d$ and the VS removal ratio of 85%. T-RFLP analysis about the community of bacteria and methanogen is also conducted to check the change of the microbial community according to the methods of OLR increasing operation. The microbial community was changed by the methods of OLR increasing operation according to the result of T-RFLP analysis. Although the anaerobic digestion test was executed by same pilot plant, the reactivity and the tolerance of microbial community for surrounding environment could be considerably changed by the operating method for the process.


(34141) Korea Institute of Science and Technology Information, 245, Daehak-ro, Yuseong-gu, Daejeon
Copyright (C) KISTI. All Rights Reserved.