• Title/Summary/Keyword: Tensile test

Search Result 4,151, Processing Time 0.037 seconds

An Experimental Study on the Fatigue Behavior of T-Type Tension Joints with High Tension Bolt (고장력볼트 T-인장이음의 피로거동에 관한 실험적 연구)

  • Lee, Seung Yong;Choi, Jun Hyeok
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.459-465
    • /
    • 2016
  • In this paper, it was performed the fatigue test to examine the effect of cyclic loading for the simple T-joint. Axial force of bolt by clamping and the change of the force by applied load were measured in the joint. And the bolt force, the failure mode and the fatigue strength under cyclic loading were investigated. The parameters of the tension joint were set to be the flange thickness and the diameter of bolt to a different stiffness of the joint in response to the combination. From the fatigue test, failure mode of tensile joints under cyclic loading could be evaluated using a static ultimate load of the specific failure mode in EC3. The fatigue strength of the tension joints was considerably higher than the fatigue strength of the EC3(36) that does not consider a lever action. However, the additional axial force by lever action occurs to an increase in the axial force of the bolt it requires a careful evaluation of the fatigue strength.

Microtensile bond strength of resin cement primer containing nanoparticles of silver (NAg) and amorphous calcium phosphate (NACP) to human dentin

  • Arjmand, Nushin;Boruziniat, Alireza;Zakeri, Majid;Mohammadipour, Hamideh Sadat
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.3
    • /
    • pp.177-183
    • /
    • 2018
  • PURPOSE. The purpose of the current study was to evaluate the effect of incorporating nanoparticles of silver (NAg) and amorphous calcium phosphate (NACP) into a self-etching primer of a resin cement on the microtensile bond strength of dentin, regarding the proven antibacterial feature of NAg and remineralizing effect of NACP. MATERIALS AND METHODS. Flat, mid-coronal dentin from 20 intact extracted human third molars were prepared for cementation using Panavia F2.0 cement. The teeth were randomly divided into the four test groups (n=5) according to the experimental cement primer composition: cement primer without change (control group), primer with 1% (wt) of NACP, primer with 1% (wt) of physical mixture of NACP+Nag, and primer with 1% (wt) of chemical mixture of NACP+Nag. The resin cement was used according to the manufacturer's instructions. After storage in distilled water at $37^{\circ}C$ for 24 h, the bonded samples were sectioned longitudinally to produce $1.0{\times}1.0mm$ beams for micro-tensile bond strength testing in a universal testing machine. Failure modes at the dentin-resin interface were observed using a stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's post-hoc tests and the level of significance was set at 0.05. RESULTS. The lowest mean microtensile bond strength was obtained for the NACP group. Tukey's test showed that the bond strength of the control group was significantly higher than those of the other experimental groups, except for group 4 (chemical mixture of NACP and NAg; P=.67). CONCLUSION. Novel chemical incorporation of NAg-NACP into the self-etching primer of resin cement does not compromise the dentin bond strength.

An Analytical Study on Prediction Fire Resistance of CFT Column in ISO Fire (표준화재조건 CFT기둥 내화성능예측을 위한 해석적 연구)

  • Kim, Hyung-Jun;Kim, Heun-Youl
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.257-260
    • /
    • 2008
  • The heat resistance of steel materials tends to weaken due to its high heat transfer properties, which might result in deteriorated strength because of rapidly rising temperature on surface in a fire. Particularly in case of CFT column that bears tensile stress of the structure on its external steel members, a numerical analysis on deterioration of strength and variation of stress shall be first carried out to ensure the structure will have sufficient fire resistance. In the study, based on values obtained from the high temperature material property test of steel materials and concrete, the test to forecast the fire behavior of CFT column was conducted using a finite element analysis method (ABAQUS). An Analysis in a bid to predict the heat transfer and the behavior characteristics by varying the strength of the concrete filled to the range of 40MPA and 50MPA was carried out. As a result of analysis of CFT column on condition of 180-minute exposure under the standard fire condition, 123mm of strain appeared with 40MPA model, while 91mm contraction with 50MPA model.

  • PDF

Bulging of Reinforced Retaining Walls (보강토옹벽의 배부름에 관한 실험적 연구)

  • Ju, Jae-Woo;Park, Jong-Beom;Na, Hyun-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.10 no.2
    • /
    • pp.45-53
    • /
    • 2011
  • Recently reinforced retaining walls secure their position as a stabilized method of construction replacing concrete retaining walls gradually. However, in the event of using extensible reinforcement, a bulging phenomenon can be happened in the front of reinforced retaining walls. Bulging of reinforced retaining walls means a phenomenon that, in the height of an arbitrary block, the upper part and the lower part of the block don't secure a relative position in design. Therefore, it is judged that it has the necessity to be examined in design since reinforcement needs metamorphosis to some degree to display tensile force. Therefore, the study examined about how extensibility of reinforcement had an effect on movement of reinforced retaining walls through a small-scale model test with aluminum rods. The study used Changhoji(traditional korean paper made from mulberry bark) as inextensible reinforcement and membrane as extensible reinforcement. As the result of the test, rigidity of reinforcement had a lot of effects on displacement of reinforced retaining walls and generally occurrence point of the maximum horizontal displacement had a tendency transferring to the upper part of walls according to rigidity of reinforcement was increased.

Estimation of Pull-out Behavior for Steel Pile Nailing installed Foldable Wedge by Field Measurement (현장계측에 의한 접이식 웨지 장착 강관네일의 인발거동 평가)

  • Kwon, Kyo-Keun;Choi, Bong-Hyuck;Kim, Kyung-Min
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.4
    • /
    • pp.19-25
    • /
    • 2009
  • In this study, field pull-out tests were performed for steel pipe nailing installed foldable wedge and non-wedge type steel pipe nailing under the same test conditions. This is to evaluate pull-out resistance improvement effect of steel pipe nailing installed foldable wedge. Evaluating for field pull-out characteristics of steel pipe nailing installed foldable wedge was performed through analysis of ultimate pull-out resistance ($T_L$), ultimate unit skin friction ($q_s$, $u_{max}$), tensile normal stiffness ($K_{\beta}$), tension of nail. As a result, the steel pipe nailing installed foldable wedge have an effect of pull-out resistance increased about 30% in comparison with non-wedge type steel pipe nailing.

  • PDF

A Study on Creep Behavior of Geosynthetics Considering Effect of Temperature and Confining Stress (온도 및 구속응력을 고려한 토목섬유의 크리프거동에 관한 연구)

  • 방윤경;김홍택
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.291-299
    • /
    • 2003
  • The effect of temperature and soil confining stress on geosyntheic creep behaviour was studied by performing the temperature dependent confined creep tests for HDPE geogrid and geomembrane specimen. The visco-elastic creep coefficients of the geosynthetics were evaluated by the test results and it was proposed that the simple expressions for the instantaneous and limit creep strain of geosynthetics was considered as a function of temperature and confining stress on geosynthetics. Based on the time-temperature superposition principle, a master curve has been drawn for extrapolating tensile creep strains to longer time intervals(1$\times$10 $^7$min.∼1$\times$10$^{10}$min.). By using this master curves, the shift factors which can be used in establishing master curve considering confining stress on geosynthetics were carried out. Each tests was performed during 8,000∼12,000 min., with temperature ranging between 5$^{\circ}C$ and 4$0^{\circ}C$ and with confining stress ranging between 0 t/$m^2$ and 9 t/$m^2$.

Effect of Recycled Coarse Aggregate on Compressive Strength and Mechanical Properties of Concrete (순환굵은골재가 콘크리트의 압축강도 및 역학적 특성에 미치는 영향)

  • Yang, In-Hwan;Jeong, Joon-Young
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.1
    • /
    • pp.105-113
    • /
    • 2016
  • Most studies on mechanical properties of concrete with recycled aggregate was focused on the concrete with compressive strength of less than 40 MPa. Therefore, this paper concerns the compressive strength and mechanical properties of concrete with compressive strength of greater than 40 MPa containing recycled coarse aggregate (RCA). The experimental parameters were compressive strength level and replacement ratio of RCA. Compressive strength level was 45 and 60 MPa, and replacement ratio of RCA was 30, 50, 70 and 100%. The results of the test were discussed: compressive strength, elastic modulus, split tensile strength and modulus of rupture. Test results of elastic modulus were compared to the design code predictions. The design code predictions for elastic modulus overestimated the experimental results. However, the design code predictions for modulus of rupture were generally in agreement with the measured values.

Fatigue Behavior of Offshore Topside Structure (상부 해양 요소 접합부의 피로 평가)

  • Im, Sung-Woo;Park, Kwan-Kyu;Park, Ro-Sik;Cho, Won-Chul;Jo, Chul-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.6 s.73
    • /
    • pp.88-92
    • /
    • 2006
  • Large-scale model tests of welded topside joints were carried out to observe the fatigue behavior of API 2W Gr.50 steel produced by POSCO. The fatigue crack behaviors for various loading conditions were measured and investigated around the critical joint sections. The experimental results have been verified with numerical approaches and also compared with the AWS D1.1 and DnV RP-C203 design curves. The large-scale experiment models were fabricated, based on the actual operating east area fixed platform. The dimensions of the models were slightly modified to accommodate the test facilities and capacities. The fatigue test was carried out having ${\Delta}Q$ of T1=705.6kN, T2=749.7kN and T3=793.8kN. The three specimens were statically loaded 20 times, with various loadings of about 50kN intervalsbetween the maximum and minimum loads required in the fatigue tests. This loading removed the residual stress in the specimen before the fatigue tests. The topside joint crack was initiated from the brace heel, where the maximum tensile stress occurred. The API 2W Gr.50 steel satisfied the AWS D1.1 detail category C and DnV RP-C203 detail category F ${\Delta}S-N$ curve.

A Study on the Variation of Temperature and the Deformation Characteristics in Asphaltic Concrete Pavement by Air Temperature (대기온도(大氣溫度)에 따른 아스팔트포장(鋪裝) 내부(內部) 온도변화(溫度變化)와 변형특성(變形特性)에 관(關)한 연구(硏究))

  • Kang, Min Soo;Kim, Soo Sam;Lee, Suk Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1115-1128
    • /
    • 1994
  • The condition of temperature gradients in asphaltic concrete (Ascon) pavement have been analyzed based on the data collected from 5 major sites in Korea. From this. considering heat transfer by insolation flux and air temperature within pavement slab. temperature variation on the surface of pavement was computed and numerical model using the theory of thermal conductivity was applied to estimate the temperature gradients in depth. To investigate the present condition of asphalt generally used in Korea. the asphalt property tests were applicated on 5 different AP-3 (AC 85~100), and AP-5 (AC 60~70) asphalts classified by penetration index. Uniaxial compression test and indirect tensile test were also carried out for varying temperature conditions to analyze the effect of temperature on the deformation characteristics of Ascon pavement by calculating the variation of static elastic modulus and layer coefficients.

  • PDF

A Development of the Lightweight Wearable Robot with Carbon Fiber Composite (탄소섬유 복합재를 이용한 경량 착용형 로봇의 개발)

  • Lee, Jeayoul;Jeon, Kwangwoo;Choi, Jeayeon;Chung, Goobong;Suh, Jinho;Choi, Ilseob;Shin, Kwangbok
    • Composites Research
    • /
    • v.28 no.3
    • /
    • pp.81-88
    • /
    • 2015
  • In this paper, we evaluate structural integrity of the wearable robot by using finite element analysis, which is made of CFRP(Carbon Fiber Reinforced Plastic) composite materials to be lightened. On the basis of the ASTM(American Standard Test Method), mechanical tests of the material are carried out in tensile, compressive and shear test for analytical evaluation. With the tested composite material, the main frame and two femoral frames of the robot is redesigned to satisfy the lightening design requirements. It is verified with the structural analysis that the redesigned frames are good for the part of the wearable robot.